Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate ▷ View online
- Page 29 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply …………………………………………….....:
apply …………………………………………….....:
Not intended for outdoor use
N/A
A.10.2 Insulation
requirements
N/A
A.10.2.1
Enclosure provides protection against splashing
water .......................................................:
water .......................................................:
N/A
A.10.2.2
Humidity treatment carried out for 7 days …………:
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1 …………………..:
No TNV circuits
N/A
Complies with IEC 62151 clause 2 …………………..:
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
………………...…:
modified to 2.4.10 of this standard
………………...…:
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard …………………………………:
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard …………………………………:
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard ………………………………………...…:
modified in accordance with annex B of this
standard ………………………………………...…:
N/A
Complies with IEC 62151 clause 6 …………………..:
N/A
Complies with IEC 62151 clause 7 ………………...:
N/A
Complies with IEC 62151 annex A, B and C ……….:
N/A
- Page 30 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-
industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment
which is intended for connection to the building
installation via a non-industrial plug or a non-
industrial
appliance coupler or both and in addition is intended
for connection to other equipment or a network shall,
if safety relies on connection to protective earth or if
surge suppressors are connected between the
network terminals and ACCESSIBLE parts, have
a marking stating that the equipment must be
connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
In Finland;
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
”Laite on liitettävä suojamaadoituskoskettimilla
va rustettuumpistorasiaan”
In Norway; ”Apparatet mǻ tikoples jordet stikkontakt”
In Sweden; ”Apparaten skall anslutas till jordat
uttag”
uttag”
Class II apparatus.
N/A
- Page 31 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used ………:
apparatus indicating type or model number of flash
apparatus with which it is to be used ………:
No electronic flash apparatus
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used …………:
model number of battery chargers or Supply
apparatus with which it is to be used …………:
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.6
L11.2.6
Lithium batteries meet permissible temp rise in Table
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4 ………………………....:
3 , unless comply with 6.2.2.1.or 6.2.2.2 of IEC
60086-4 ………………………....:
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE ………………………:
HAZARDOUS LIVE ………………………:
Not flash synchroniser.
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency puls ignition ………..:
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test ……………………………...:
impact test ……………………………...:
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions ………….:
function under normal conditions ………….:
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE …..:
to be a POTENTIAL IGNITION SOURCE …..:
N/A
- Page 32 of 44 -
Report
No.
129952
TRF No. IEC60065_I
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by position of
the functional switch (W)
the functional switch (W)
Less than 0.95W
(at 240V)
(at 240V)
—
Operating conditions
Standby mode at 50Hz;
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0.0051 0.87
—
240 0.0056 0.95
—
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0.0042 0.83
—
240 0.0043 0.88
—
Measured at maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264 5.07 1112
F)
2 x 78.0
SB) 2 x 75.3
C)
C)
1 x 74.4
S)
2 x 76.6
Measured at maximum non-clipped output at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
264 4.94 1078
F)
2 x 78.0
SB) 2 x 75.3
C)
C)
1 x 74.4
S)
2 x 76.6
Tested condition; 1kHz input signal, connected 8 ohm loads for F, SB, C, S channels
Click on the first or last page to see other AVR 460 (serv.man2) service manuals if exist.