Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate ▷ View online
- Page 13 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
10 Insulation
requirements
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
surge test for basic and 4 MΩ min. for reinforced
insulation ……………………………………………..:
> 100 M
Ω after surge test
P
10.2
Humidity treatment 48 h or 120 h ………………….:
Performed for 120 h at temp.
40
40
°C and humidity 93%
P
10.3
Insulation resistance and dielectric strength between
mains terminals ……………………………………...:
mains terminals ……………………………………...:
(see appended table 10.3)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1) :
BASIC or SUPPLEMENTARY insulation (Class 1) :
Class II apparatus
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II) ……………..:
REINFORCED insulation (Class II) ……………..:
(see appended table 10.3)
P
11 Fault
conditions
11.1
No shock hazard under fault condition ……………:
No electric shock hazard under
fault conditions.
fault conditions.
P
11.2
Heating under fault condition ……………………….:
(see appended table 11.2)
P
Flames extinguish within 10 seconds ....................:
No flames
P
No hazard from softening solder …………………...:
No softening of solder
P
Soldered terminations not used as protective
mechanism ………………………………………..:
mechanism ………………………………………..:
No soldered terminations
P
11.2.1
Measurement of temperature rises ……..:
(see appended table 11.2)
P
11.2.2
Temperature rise of accessible parts ……...:
(see appended table 11.2)
P
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation ………………:
providing electrical insulation ………………:
(see appended table 11.2)
P
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min ……………...:
exceeding the limits of table 3 by max. 100 K for
max. 5 min ……………...:
No exceeding the limits of
Table 3.
Table 3.
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² …:
to 20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm² …:
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min ……………………….:
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min ……………………….:
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
………………...:
printed circuit boards are interrupted
………………...:
No conductors are
interrupted/peeled/loosened
during fault conditions
interrupted/peeled/loosened
during fault conditions
P
- Page 14 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Class I protective earthing maintained ………….:
Class II equipment
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier ….:
mechanical barrier ….:
(see appended table 11.2)
P
11.2.5
Temperature rise of windings ………………:
(see appended table 11.2)
P
11.2.6
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.5 ………………:
11.2.1 to 11.2.5 ………………:
No excessive temperature
observed/measured on
other parts.
(see appended table 11.2)
observed/measured on
other parts.
(see appended table 11.2)
P
12 Mechanical
strength
12.1.1
Bump test where mass >7 kg ……………………...:
No damage in the sense of
this standard
this standard
P
12.1.2
Vibration test …………………………………………:
Assessed to be satisfactory
constructed.
constructed.
N/A
12.1.3
Impact hammer test ………………………………...:
No damage in the sense of
this standard
this standard
P
Steel ball test ………………………………………...:
No damage in the sense of
this standard
this standard
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
…………………………………………………...........:
…………………………………………………...........:
Not portable apparatus
N/A
12.1.5
Thermoplastic enclosures stress relief test ……….:
Tested, 70ºC, 7h
P
12.2
Fixing of knobs, push buttons, keys and levers …..:
Normal use will not impair the
protection against electric
shock.
protection against electric
shock.
P
12.3
Remote controls with hazardous live parts ………….:
No cable connected
remote control devices.
remote control devices.
N/A
12.4
Drawers (pull test 50 N, 10 s) ………………………:
No drawers
N/A
12.5
Antenna coaxial sockets providing isolation ………:
No antenna
N/A
12.6
Telescoping or rod antennas construction ….…….:
No telescoping or rod antennas
N/A
12.6.1
Telescoping or rod antennas securement ………......:
N/A
- Page 15 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
13
Clearances and creepage distances
13.1
Clearances in accordance with 13.3 ………………:
See 13.3
P
Creepage distances in accordance with 13.4 …….:
See 13.4
P
13.2
Determination of operating voltage …..……:
Conventional
linear transf. used.
Rated supply voltage (240V)
applied in determining the
operating voltage.
applied in determining the
operating voltage.
P
13.3 Clearances
2N for internal parts and 30N
for enclosures are considered
when determining clearances.
for enclosures are considered
when determining clearances.
P
13.3.1 General
…………………………:
Considered
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ………..:
with table 8 and, where applicable, table 9 ………..:
(see appended table 13)
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10 ……………...:
comply with table 10 ……………...:
No hazardous secondary
voltages
voltages
N/A
13.3.4
Measurement of transient voltages ………..:
No measurement of transient
voltages
voltages
N/A
13.4
Creepage distances ……………...:
CTI > 100
(see appended table 13)
(see appended table 13)
P
Creepage distances greater than table 11 minimum
values …………………...:
values …………………...:
Not applicable
N/A
13.5
Printed boards
Refer to below
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10 ……………………:
No such PCB used
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only) ………..:
IEC 60664-3 (basic insulation only) ………..:
No type B coated printed
circuit boards
circuit boards
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
clearances and creepage distances comply with
13.3 and 13.4 ………….............:
No uncemented joints
N/A
Conductive parts along reliably cemented joints
comply with 8.8 ………………:
comply with 8.8 ………………:
N/A
Temperature cycle test and dielectric strength test :
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12:
not conductively connected to the mains, clearances
and creepage distances as in table 12:
No enclosed, enveloped or
hermetically sealed parts
hermetically sealed parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8 ………………………:
requirements of 8.8 ………………………:
No parts filled with insulating
compound.
compound.
N/A
- Page 16 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts ………………………………:
accessible metal parts ………………………………:
No such resistors
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
…………………………………..:
parts and accessible parts
…………………………………..:
Not used
N/A
Resistors separately approved ……………………….:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved ……………...……:
Yes, see below
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition …:
No Y capacitors
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition …:
Capacitors C904 certified
according to
IEC 60384-14, 2
according to
IEC 60384-14, 2
nd
edition,
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ………………:
connected to the mains: tests for X2 ………………:
No such capacitors
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ……:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ………………………:
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ………………………………………….:
metal ………………………………………….:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4 …………….:
(as relevant) and clause 20.1.4 …………….:
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type …………….:
manufacturer's name and type …………….:
Adequate marking applied.
Mfr, ID and type no.
Mfr, ID and type no.
P
Transformers and inductors separately approved ….:
No
N/A
14.3.2 General
……………………………:
Isolating transformers
P
Insulation material complies with clause 20.1.4 …:
Considered. The insulation
material of isolating transf.
complies with flammability
category of Table 21.
material of isolating transf.
complies with flammability
category of Table 21.
P