Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate ▷ View online
- Page 21 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases ………………………………………:
flammable gases ………………………………………:
No batteries.
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries ………………………………………………:
batteries ………………………………………………:
N/A
14.10.3
Recharging currents and times within manufacturers
limits …………………………………………………….:
limits …………………………………………………….:
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits ……………………….:
within the manufacturers limits ……………………….:
N/A
14.10.4
Battery mould stress relief ………………………….:
N/A
14.10.5
Battery drop test ……………………………………..:
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8 ………………………:
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation) ………………:
alternatively 13.6 (jointed insulation) ………………:
N/A
14.12
Surge suppression varistors
No surge suppression varistors
N/A
Comply with IEC 61051-2 …………………………..:
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus …………………………………………….:
except for earthed parts of permanently connected
apparatus …………………………………………….:
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12 ………………..:
thermal stress requirements of 14.12 ………………..:
N/A
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard …………………………………...:
and mains socket-outlet meet the appropriate
standard …………………………………...:
Approved appliance inlet,
mains plug/coupler and
mains socket outlet provided.
See appended table, list of
critical components
mains plug/coupler and
mains socket outlet provided.
See appended table, list of
critical components
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets …………..:
the apparatus has mains socket outlets …………..:
Prevented by the fuse;
F902 (T 2.5A L 250V)
F902 (T 2.5A L 250V)
P
Overloading of internal wiring prevented if the
apparatus has mains socket outlets ………….:
apparatus has mains socket outlets ………….:
Prevented by the fuse;
F902 (T 2.5A L 250V)
F902 (T 2.5A L 250V)
P
15.1.2
Connectors for antenna, earth, audio, video or
data .:
data .:
P
- Page 22 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
No risk of insertion in mains socket-outlets ….:
Only RCA, Antenna, Optical,
HDMI, USB,
HDMI, USB,
A-BUS,
Mini jack
terminal used.
Banana play type speaker
terminal also used, but they
are accepted due to below
note.
Note) Banana type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
Banana play type speaker
terminal also used, but they
are accepted due to below
note.
Note) Banana type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2 …......................:
marked with the symbol of 5.2 …......................:
No sockets indicated with
the symbol
the symbol
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-
outlets :
not compatible with household mains socket-
outlets :
The equipment under test is
not an adaptor.
not an adaptor.
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus.
N/A
Protective earth conductors correctly coloured …..:
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
….................................................................:
provided with separate protective earth terminal
near mains input
….................................................................:
N/A
Protective earth terminal resistant to corrosion …..:
N/A
Earth resistance test: < 0,1
Ω at 25 A ……….:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
N/A
15.3.1
Adequate terminals for connection of permanent
wiring ……………………………………………...….:
wiring ……………………………………………...….:
Appliance inlet applied
N/A
15.3.2
Reliable connection of non-detachable cords …….:
N/A
Not soldered to conductors of a printed circuit
board :
board :
N/A
Adequate clearances and creepage distances
between connections should a wire break away …:
between connections should a wire break away …:
N/A
Wire secured by additional means to the conductor:
N/A
- Page 23 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar .:
adequate threads: ISO 261, ISO 262 or similar .:
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means ….:
to soldering or held in place by additional means ….:
Appliance inlet applied
N/A
Clamping of conductor and insulation if not soldered
or held by screws ……………………………………:
or held by screws ……………………………………:
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment
………………………………………….:
sectional area of conductors, for the rated current of
the equipment
………………………………………….:
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16 :
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure ……………………………:
have adequate pressure ……………………………:
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened ………………………..:
when tightened or loosened ………………………..:
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided ...……………...................:
the clamping is tightened or loosened and stress on
internal wiring is avoided ...……………...................:
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic ……………………………:
contact pressure not transmitted by insulating
material except ceramic ……………………………:
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other …………………...:
terminated near to each other …………………...:
N/A
Terminals located and shielded: test with 8 mm
strand ………………………………………:
strand ………………………………………:
N/A
15.4
Devices forming a part of the mains plug
N/A
15.4.1
No undue strain on mains socket-outlets ……:
The apparatus is not a device
forming a part of the mains plug.
forming a part of the mains plug.
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs …………………………………….:
mains plugs …………………………………….:
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c) ……………………………………….:
a,b,c) ……………………………………….:
N/A
- Page 24 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ………………………….:
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ………………………….:
Sheathed PVC cord
complying with IEC 60227
complying with IEC 60227
P
Non-detachable cords for Class I have green/yellow
core for protective earth ………………….:
core for protective earth ………………….:
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment …………………………………:
sectional area for rated current consumption of the
equipment …………………………………:
The cord is 0,75mm²,
within the current rating
within the current rating
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength …………………………:
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength …………………………:
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of
IEC 60227-2):
bending and mechanical stress (3.2 of
IEC 60227-2):
Cord complying with 16.1.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions ……………………….:
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions ……………………….:
Cords have adequate
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
cross-sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords …:
Appliance inlet provided
N/A
Not possible to push cord back into equipment …..:
N/A
Strain relief device unlikely to damage flexible cord
N/A
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor
live conductors become taut before earth conductor
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use …………………………………:
damage to the cord during assembly or movement
in use …………………………………:
Appliance inlet provided
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1 ………………………:
fitted with detachable cord set with appliance inlet to
IEC 60320-1 ………………………:
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord ……………………...:
fitted with detachable cord sets or with means of
stowage to protect the cord ……………………...:
N/A