Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
17
Electrical connections and mechanical fixings
17.1
Torque test to table 20
P
- screws into metal: 5 times ………………………...:
see appended table 17.1
P
- screws into non-metallic material: 10 times ……..:
No non-metallic material
N/A
17.2
Correct introduction into female threads in non-
metallic material ……………………………………..:
metallic material ……………………………………..:
No female threads in
non-metallic materials
non-metallic materials
N/A
17.3
Cover fixing screws: captive ………………………..:
Captivity not necessary
P
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter ….:
by a screw whose length is 10 times its diameter ….:
Tested with screw with
10 times diameter.
10 times diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A ………………………………………………..:
> 0,2 A ………………………………………………..:
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A ………………………………..:
other than ceramic for connections carrying a current
> 0,2 A ………………………………..:
No contact pressure transmitted
through insulating material.
through insulating material.
P
17.6
Stranded conductors of flexible supply cords carrying
a current > 0,2 A with screw terminals not
consolidated by solder …………………:
a current > 0,2 A with screw terminals not
consolidated by solder …………………:
Appliance inlet provided
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous ……………………………………...:
adequate strength and their positioning is
unambiguous ……………………………………...:
No cover fixing devices
other than screws
other than screws
N/A
17.8
Fixing devices for detachable legs or stands
provided ……………………………:
provided ……………………………:
No detachable provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected ……………..:
unlikely to become disconnected ……………..:
Connections complies,
checked by inspection
checked by inspection
P
- Page 26 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
Picture tube separately approved to IEC 61965 .:
No CRT in the equipment.
N/A
Picture tube separately approved to 18.1 ..…….….:
N/A
18.1
Picture tubes >16 cm intrinsically protected ….….:
N/A
Non-intrinsically protected tubes >16 cm used with
protective screen ..…………………………......:
protective screen ..…………………………......:
N/A
Protective film as part of implosion protection: edges
covered by enclosure ..…………………...…:
covered by enclosure ..…………………...…:
N/A
18.2
Intrinsically protected tubes: tests on 12 samples :
N/A
18.2.1
Samples subject to ageing: 6 samples ……………:
N/A
18.2.2
Samples subject to implosion test: 6 samples …:
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples ..…………………………………….:
ball): 6 samples ..…………………………………….:
N/A
18.3
Non-intrinsically protected tubes tested to 18.3 ..:
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg ..………….:
Weight: 13.7kg
⎯
Apparatus intended to be fastened in place –
suitable instructions …………………………….….:
suitable instructions …………………………….….:
No
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal …..:
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards ..…….:
100N force have no influence
on the stability
on the stability
P
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability ….…………………………….:
point of least stability ….…………………………….:
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous ……………….....:
There is no hazardous edges
or corners when the
apparatus is operating in
normal position
or corners when the
apparatus is operating in
normal position
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate ………….:
Not intended for wall or ceiling
mounting
mounting
N/A
- Page 27 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
20
Resistance to fire
20.1
Electrical components and mechanical parts
N/A
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width …………:
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width …………:
N/A
b) Exemption for small components as defined in
20.1 ………………………………………………...:
20.1 ………………………………………………...:
PCB is of flammability class
V-0 or better, and exception
is made for small components.
V-0 or better, and exception
is made for small components.
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4 ……………………………....:
Clause 14 or 20.1.4 ……………………………....:
Electrical components comply
with flammability requirements in
clause 14.
with flammability requirements in
clause 14.
N/A
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire …………………...:
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire …………………...:
No wires working at
voltages > 4kV or leaving
an internal fire enclosure
voltages > 4kV or leaving
an internal fire enclosure
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire
enclosure ..:
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire
enclosure ..:
All PCB is of base material
with flammability category
V-0 or batter.
See appended table, list of
critical components
with flammability category
V-0 or batter.
See appended table, list of
critical components
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707 ………:
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707 ………:
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N/A
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21 ………………….:
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21 ………………….:
Bobbin of transformers, rated
94V-0.
94V-0.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13 ……………..:
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13 ……………..:
No such components
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure ………………………………………..…...:
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure ………………………………………..…...:
Normal operating voltage
< 4KV
N/A
- Page 28 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
20.2 Fire
enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1 …………………………………..:
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1 …………………………………..:
No voltages exceeding
4kV, no fire enclosure
requirement
4kV, no fire enclosure
requirement
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled ……………………………………..:
1 mm in width and with openings for wires
completely filled ……………………………………..:
No internal fire enclosure.
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure ……………………………….:
internal fire enclosure ……………………………….:
No internal fire enclosure.
N/A