DOWNLOAD Harman Kardon AVR 460 (serv.man2) Service Manual ↓ Size: 2.54 MB | Pages: 65 in PDF or view online for FREE

Model
AVR 460 (serv.man2)
Pages
65
Size
2.54 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-460-sm2.pdf
Date

Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate ▷ View online

 
 
- Page 33 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
TRF No. IEC60065_I 
Measured at 1/8 of maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 2.20 
#) 2.18 
349.2 
#) 343.1 
 
 
 
F) 
2 x 9.75 
SB)  2 x 9.41 
C) 
1 x 9.30 
S) 
2 x 9.58 
 
 
230 2.26 
#) 2.23 
395.2 
#) 389.2 
240 2.28 
#) 2.25 
414.4 
#) 410.2 
264 2.32 
#) 2.29 
463.5 
#) 457.3 
Measured at 1/8 of maximum non-clipped output at 60Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
207 2.18 
#) 2.16 
348.4 
#) 341.0 
 
 
 
F) 
2 x 9.75 
SB)  2 x 9.41 
C) 
1 x 9.30 
S) 
2 x 9.58 
 
 
230 2.23 
#) 2.19 
393.1 
#) 384.2 
240 2.26 
#) 2.22 
412.7 
#) 407.1 
264 2.30 
#) 2.27 
462.7 
#) 455.0 
 
 
 
 
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads for all channels connected 
condition, and then replaced the input signal to pink noise for normal heating and fault condition tests for fan 
stalled and blocked opening (Other tests in the fault condition tests were performed with 1 kHz sign wave 
input signal for monitoring the signal outputs). 
The values followed #) in table above are measured “A” or “W” values, when replaced the input signal from 
1 kHz sign wave to pink noise. 
 
 
Loudspeaker impedance (Ω)  .........
8 Ohms 
— 
 
Several loudspeaker systems 
Right and Left for Front, 
Right and Left for Surround Back / Zone 2, 
Right and Left for Surround, 
Only one for Center. 
 
Marking of loudspeaker terminals
SPEAKERS (8Ω):  
FRONT RIGHT, FRONT LEFT,  
SBR/ ZONE 2 R, SBL/ZONE 2 L,  
SURR. RIGHT, SURR. LEFT, CENTER. 
 
 
 
- Page 34 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
TRF No. IEC60065_I 
7.1 
TABLE: temperature rise measurements 
Monitored point: 
dT (K) at  
207V / 50Hz
dT (K) at 
264V / 50Hz
dT (K) at  
207V / 60Hz 
dT (K) at  
264V / 60Hz 
Permitted 
dT (K) 
Main transformer core 
51.5  
65.0  
52.1  
63.9  
95 
Sub transformer core 
33.0  
39.9  
35.7  
39.2  
85 
PWB near D701 
36.2  
44.1  
36.4  
44.4  
95 
PWB near D991 
51.1  
56.3  
53.8  
55.0  
95 
PWB near IC83 
50.9  
72.4  
51.8  
72.8  
95 
PWB near Q803 
48.3  
66.5  
50.1  
66.4  
95 
FAN body (installed in back cover inside)  26.9  
33.4  
27.1  
33.7  
FAN body (
installed in main heat-sink
23.6  
30.8  
25.4  
30.4  
E Capacitor, C916 body 
26.2  
30.2  
26.2  
30.0  
85 
°C 
E Capacitor, C129 body 
33.0  
43.5  
35.5  
43.8  
85 
°C 
CN91 AC connector 
24.8  
31.0  
26.7  
30.5  
200 
°C   *) 
CN92 AC connector 
29.2  
36.1  
31.4  
35.3  
200 
°C   *) 
Heat-sink of D701 
39.0  
45.7  
39.3  
46.1  
Heat-sink of D991 
60.5  
67.4  
65.6  
65.4  
Main heat-sink 
56.5  
79.7  
57.0  
80.0  
Inlet body (Inside) 
19.2  
25.2  
23.1  
24.6  
Enclosure top above main heat-sink 
33.3  
45.2  
35.4  
45.8  
65  **) 
Enclosure top above main transformer 
27.5  
37.4  
28.0  
36.8  
40  ***) 
Enclosure top above main heat-sink 
33.8 
38.4 
35.9 
38.4  
40  ***) 
Stand-by button (non-metallic) 
7.1  
9.3  
7.8  
10.5  
50 
Front panel (non-metallic) 
12.9  
17.6  
12.6  
18.0  
60 
Mains switch button (rear side) 
10.4  
12.7  
10.6  
12.4  
50 
Ambient 23.7°C 
22.6°C 
21.5°C 
22.6°C 
 
 
 
 
 
 
*) Based on softening temperature test (see table 7.2). 
**) Directly covering part for heat-sink. The top cover is supplied with ventilation openings covering most of 
the top cover, and apply the hot surface symbol (IEC 60417-5041). This indicates emission of heat from 
internal parts and the opening area is therefore not likely to be touched during normal use. Max. temperature 
rises measured in the enclosure top did not exceed 45.8K. 
***) Top cover surface with ventilation openings at 150 mm distance from the control knobs. Other areas not 
exceeding 150mm distance from the control knobs, temperature rises measured did not exceed 40K. 
 
 
- Page 35 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
TRF No. IEC60065_I 
 
Winding temperature rise 
measurements 
207V 
50Hz 
264V 
50Hz 
207V 
60Hz 
264V 
60Hz 
— 
 
Ambient temperature t1 (
o
C) : 
22.0 22.0 22.0 22.0 
— 
 
Ambient temperature t2 (
o
C) : 
23.7 22.6 21.5 22.6 
— 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Permitted 
dT (K) 
Insulation 
class 
Main transf. primary winding (264V, 50Hz) 
1.848 
2.448 
82.7 
95 
Sub transf. primary winding (264V, 50Hz) 
3542 
4180 
45.6 
85 
 
 
 
 
 
 
Main transf. primary winding (264V, 60Hz) 
1.848 
2.441 
81.7 
95 
Sub transf. primary winding (264V, 60Hz) 
3542 
4156 
43.9 
85 
 
 
 
 
 
 
Main transf. primary winding (207V, 50Hz) 
1.848 
2.336 
66.0 
95 
Sub transf. primary winding (207V, 50Hz) 
3542 
4085 
37.6 
85 
 
 
 
 
 
 
Main transf. primary winding (207V, 60Hz) 
1.848 
2.337 
68.4 
95 
Sub transf. primary winding (207V, 60Hz) 
3542 
4083 
39.7 
85 
 
 
 
 
 
 
 
 
 
- Page 36 of 44 - 
 
 
 
 
 Report 
No. 
129952 
 
TRF No. IEC60065_I 
7.2 
TABLE: softening temperature of thermoplastics 
Temperature T of part 
T - normal conditions 
(
o
C) 
T - fault conditions 
(
o
C) 
 Min T softening  
(
o
C) 
Mains connector (CN91) 
31.0 (53.6 °C) 
(I/P=264V, ambient 
22.6 °C) 
44.3 (67.0 °C) 
(I/P=264V, ambient 
22.7 °C) 
> 200 
(type, YW396 series)
 
Mains connector (CN92) 
36.1 (58.7 °C) 
(I/P=264V, ambient 
22.6 °C) 
47.6 (70.3 °C) 
(I/P=264V, ambient 
22.7 °C) 
> 200 
(type, YW396 series)
 
 
 
 
 
 
 
9.1.1.1 
Touch current expressed as voltages U1 and U2 in Annex D 
Location 
Measured  
U1V (peak) 
Measured  
U1 V (DC) 
Measured  
U2 V (peak) 
Limits :  
U1 Max 35V (peak) 
U1 Max  1.1V (DC) 
U2 Max 0.35V (peak) 
Pole 1 – Antenna Terminal 
Pole 2 - Antenna Terminal 


0.03V peak 
0.02V peak 
Pass 
Pass 
Pole 1 - other part or contact 
Pole 2 - other part or contact 


0.03V peak 
0.02V peak 
Pass 
Pass 
 
 
 
 
 
Comments: 
 
Vin=264Vac, 60Hz
 
Only U2 have been recorded due to the use of a linear transformer in power supply. 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
> 100 
Min 2 
Between parts separated by double or reinforced insulation 
> 100 
Min 4 
 
 
 
 
10.3 
TABLE: electric strength measurements 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
1500Vac No 
Between parts separated by double or reinforced insulation 
3000Vac No 
 
 
 
Page of 65
Display

Click on the first or last page to see other AVR 460 (serv.man2) service manuals if exist.