Harman Kardon AVR 460 (serv.man2) EMC - CB Certificate ▷ View online
- Page 17 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13 ……………………………..:
clause 13 ……………………………..:
(see appended table 13)
P
14.3.3.2 Transformers
meet
the constructional requirements:
(see appended table 14.3.3)
P
14.3.4
Separation between windings
P
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
insulation between primary
and secondary windings
according to clause 8.8.
(see appended table 14.3.3)
P
Coil formers and partition walls > 0,4 mm ……...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………………….:
protective screening only if all 7 conditions of
14.3.4.2 are met ……………………………………….:
Class II apparatus.
No such transformer used.
No such transformer used.
N/A
14.3.4.3
Separating transformers with at least basic
insulation:
insulation:
Windings of Class II
construction used.
construction used.
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
between hazardous live parts and accessible parts
(double or reinforced insulation) …………………...:
Double or reinforced insulation
between hazardous live
windings and accessible
conductive parts.
between hazardous live
windings and accessible
conductive parts.
P
Coil formers and partition walls > 0,4 mm ………...:
Main and Sub transf. bobbin
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
fulfils the requirement of
reinforced insulation; bobbin
thickness > 0,4 mm.
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal …………………………………………………:
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal …………………………………………………:
Winding of Class II
construction used.
construction used.
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity ………………..:
adequate current-carrying capacity ………………..:
N/A
14.4
High voltage components …………………………..:
No high-voltage components.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved ………….....................:
(peak) separately approved ………….....................:
N/A
- Page 18 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
Component meets category V-1 of IEC 60707
…......:
…......:
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission ………………………………:
part of the submission ………………………………:
N/A
14.5 Protective
devices
P
Protective devices used within their ratings ………:
Thermal link and fuses
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened ………………………......:
requirement of clause 13 for the voltage across the
device when opened ………………………......:
Certified protective devices
applied. See appended table,
list of critical components.
applied. See appended table,
list of critical components.
P
14.5.1.1
a) Thermal cut-outs separately approved …………:
No thermal cut-outs
N/A
b) Thermal cut-outs tested as part of the submission:
N/A
14.5.1.2
a) Thermal links separately approved …………..:
Thermal link in main transf.,
separately approved compo.
See appended table,
list of critical components
separately approved compo.
See appended table,
list of critical components
P
b) Thermal links tested as part of the submission ….:
N/A
14.5.1.3
Thermal devices re-settable by soldering …………:
No such thermal device
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
……………………………………………….......:
60127
……………………………………………….......:
Fuses are approved
components according to
IEC 60127.
See appended table, list of
critical components.
components according to
IEC 60127.
See appended table, list of
critical components.
P
14.5.2.2
Correct marking of fuse-links adjacent to
holder ……:
holder ……:
The following marking applied;
Mains fuses;
F901: T6.3A L 250V
F902: T2.5A L 250V
F901: T6.3A L 250V
F902: T2.5A L 250V
Secondary fuse;
F110: T5A L 250V
F111: T5A L 250V
F110: T5A L 250V
F111: T5A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ………….:
No fuse holder so designed
that fuse-links can be
connected in parallel
that fuse-links can be
connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ……..:
replacing fuse-links without the use of a tool ……..:
No replacement of fuse
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
……….:
……….:
No PTC’s thermistors.
N/A
- Page 19 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
PTC-S devices (15 W) category V-1 or better
………:
………:
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked …………......:
No such components
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ……………...:
Mains switch and relay are
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
certified components
according to IEC 61058-1.
See appended table,
list of critical components.
P
14.6.1 b)
Tested in the apparatus …………………….:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………………….:
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………………….:
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 …………………………………:
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 …………………………………:
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………………:
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………………:
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ………………...:
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ………………...:
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ……………………:
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ……………………:
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength ………………………………………...….:
strength ………………………………………...….:
Separately approved switch
and relay.
and relay.
N/A
- Page 20 of 44 -
Report
No.
129952
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1 …………………….:
additional tests to IEC 60058-1 …………………….:
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K..
is less than rated current of
the mains switch (6A) - O.K..
Measured inrush current
through mains relay;
19A + 20 A * = 39 A
*) Added current for socket
outlet (
through mains relay;
19A + 20 A * = 39 A
*) Added current for socket
outlet (
Socket outlet current
marking
: 0.5 A).
The measured inrush current
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
value is less than rated inrush
current rating of the mains
relay (100A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
controlled by the mains relay).
P
Socket outlet current marking correct …………..:
Socket outlet marking:
SWITCHED (50W, 0.5A MAX)
SWITCHED (50W, 0.5A MAX)
P
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950 …………......:
No safety interlock
N/A
14.8
Voltage setting devices and the like ……………….:
No voltage setting devices.
N/A
Voltage setting device not likely to be changed
accidentally ………………………………………......:
accidentally ………………………………………......:
N/A
14.9 Motors
Low voltage DC fan motors.
P
14.9.1
Endurance test on motors …………………………….:
N/A
Motor start test …………………………………………:
N/A
Dielectric strength test ………………………………:
N/A
14.9.2
Not adversely affected by oil or grease etc. ………..:
The fans are not adversely
affected by oil, grease or other
substances.
affected by oil, grease or other
substances.
P
14.9.3
Protection against moving parts ………………...:
The fans are placed inside the
unit. No access.
unit. No access.
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ……………………….:
No such construction.
The fans are low voltage DC
components only.
The fans are low voltage DC
components only.
N/A