 Report 
No. 
123035 
 
TRF No. IEC60065_I 
13 
TABLES: clearances and creepage distances 
Rated supply voltage: 
230 V 
Pollution degree: 
Material Group: 
IIIb 
*) 2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
Yes 
Type of  
Insulation 
Position/ Location 
Operating Voltage Clearance (mm)
Creepage (mm)
Com
m
V peak
V rms
Min 
Actual
Min 
Actual
Circuits conductively connected to the mains (use Tables 8 and 11): see note below.
 
Basic Live Neutral 326V 
230V 
2.0 
3.5 
2.5 
3.5 
1) 
Reinforce Primary  Secondary  326V 230V 
4.0  5.2  5.0  5.2  2) 
Reinforce 
Primary *)  Chassis 326V 
230V 
4.0 
7.0 
5.0 
7.0 
3) 
Reinforce Primary  Secondary  385V 272V 
4.0  6.0  5.8  6.0  4) 
 
 
 
 
 
 
 
 
 
 
Comments: 
1)  Measured on pcb before mains fuse. 
2)  Measured between primary pcb trace and near metal chassis (back cover).  
3)  Measured between primary solder pin and near metal chassis (bottom). 
4)  Measured on main pcb from pri. trace to near secondary trace. 
 
 
 
- Page 40 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
14.3.3 
Transformer/motor, constructional requirements 
Transformer 
Part No. 
Insulation 
between 
Insulation  
Res. M Ohms
Test Volt 
V (60 sec.)
Clearances / Creepage distances
Measured 
Required 
CLT(or KLT)5U036ZE 
Pr - sec 
>100 
3KV(rms) 
10.1 / 10.1mm  4.0 / 5.8mm 
Pr - ic 
>100 
3KV(rms) 
9.9 / 9.9mm 
4.0 / 5.0mm 
 
 
 
 
 
 
CLT(or KLT)5I009ZE 
Pr - Sec 
> 100 
3 kV (rms) 
6.9 / 6.9 mm 
4.0 / 5.0 mm 
Pr - ic 
> 100 
3 kV (rms) 
5.2 / 5.2 mm 
4.0 / 5.0 mm 
Components / construction 
CLT(or KLT)5U036ZE  
Windings on two separate bobbins. The bobbins are  
placed in an insulating housing with two compartments, 
one above the other. Bobbin thickness: > 0.4mm. 
 
Max. Operating voltage: 385Vp/272Vrms 
Components / construction 
CLT(or KLT)5I009ZE 
Windings on single bobbin. The center flange provided 
between primary and secondary windings.  
Satisfactory constructed. Bobbin thickness: > 0.4mm. 
Max. Operating voltage: 338Vp/239Vrms 
Transformer 
Part No 
Insulation 
Between 
Thick (mm) 
X Number 
Material 
Dielectric strength  
test / 60 sec. 
CLT(or KLT)5U036ZE 
Pr - sec 
1.00 min. x 1 
PBT sec. bobbin 
1 layer  – Pass  *) 
Pr - ic 
1.00 min. x 1 
PBT pri. bobbin 
1 layer  – Pass  *) 
 
 
 
 
 
CLT(or KLT)5I009ZE 
 
Pr - sec 
0.70 mm min. x 2
0.70 mm min. x 1
PBT bobbin flange 
PBT bobbin cap. 
1 layer  – Pass   *) 
Pr - ic 
0.60 mm min. x 1
PBT bobbin 
1 layer  – Pass   *) 
Pr - ic 
0.60 mm min. x 1
PBT bobbin cap. 
1 layer  – Pass   *) 
*) Test voltage: 3000 Vrms. 
 
17.1 
Torque test to Table 20:   
Screw 
Diameter 
With 
Without
Material 
Torque test (Nm) 
Location / function 
(mm) 
Head 
Head 
Screw
Nut 
Fulfilled / Remarks 
Fixing of top cover 
(sides) 
4.0 
Metal
Metal
Tested with 1.2Nm, 
5 times / Pass 
Fixing of top cover 
(rear) 
3.0 
Metal
Metal
Tested with 0.5Nm, 
5 times / Pass 
 
 
 
 
 
 
 
 
 
 
- Page 41 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
14 
TABLE: list of critical components and materials 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
1
) 
Mains plug/cord 
(For CENELEC) 
KENIC 
ELECTRIC. 
KE-21 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. KENIC 
ELECTRIC. 
KE-32 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. PHINO 
ELECT. 
PHP-205 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
alt. VOLEX 
(ASIA) 
PTE. 
M4206 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1 VDE 
Mains plug/cord 
(For UK and 
Singapore) 
KENIC 
ELECTRIC. 
KE-108 
H03VVH2-F, or
H05VVH2-F 
13A/250V 
6A/250V 
BS1363 
SS145 
BSI 
PSB 
Mains plug/cord 
(For UK) 
PHINO ELECT. 
PHP-307F 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. VOLEX 
(ASIA) 
PTE. 
MP5004A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
VOLEX (ASIA)  
PTE. 
MP5005 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. WINBO 
INDUSTRIES 
MS 323N 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
LUEN TAI (IP’S) 
KENIC ELECT. 
9518 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
alt. 
WELL SHIN ENTE
RPRISE. 
WS-012A 
H03VVH2-F 
13A/250V 
6A/250V  
BS1363 
BS6500 
BSI 
Mains plug / cord (for other countries including Korea) : See Summary of Testing. 
Mains transf. 
 
 
Bobbin 
 
Thermal fuse 
Seoul Electronics 
& Telecom Co Ltd. 
 
LG Chemical 
 
Therm-O-Disc. 
CLT5U036ZE 
KLT55U036ZE
 
GP-2306F 
 
E4A51 
220-230V,  
Class B 
 
V-0, 140°C, PBT 
 
10A/250V, 167
°C
IEC60065 
clause 14.3 
 
UL94 
 
IEC60691 
1.) 
 
 
UL, E248280 
 
VDE 
Sub transformer 
(T902) 
 
Bobbin Mtl. 
Bobbin Cap. Mtl. 
Seoul Electronics 
 
 
LG Chemical Ltd. 
LG Chemical Ltd. 
CLT5I009ZE/ 
KLT5I009ZE 
 
GP-2306G 
GP-1006F 
220-230V, 
Class E 
  
V-0, 140°C, PBT
V-0, 130°C, PBT
IEC60065 
clause 14.3 
 
UL94 
UL94 
1.) 
 
 
UL, E67171 
UL, E67171 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition 
 
 
- Page 42 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
14 
TABLE: list of critical components and materials- continued 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
1
) 
Mains fuse 
(F901) 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Electronic. 
50T 
218 004 
5T 
TSD 
T4A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
Relay across 
the cap. (C904) 
alt. 
alt. 
alt. 
Du San 
Netron Tech. 
Sam Wha Cap. 
Murata Mfg. 
Jyh Chung  
NU 
AA 
SC 
KH 
JY 
0.0047uF/250V, 
X1. 
IEC60384-14, 
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
Switch across 
the cap. (C906) 
alt. 
alt. 
alt. 
Du San 
Netron Tech. 
Sam Wha Cap. 
Murata Mfg. 
Jyh Chung  
NU 
AA 
SC 
KH 
JY 
0.00047uF/250V,
X1. 
IEC60384-14, 
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
Mains relay 
(RY94) alt. 
Omron Corp. 
Daiichi Elect. 
G5PA-1 
DLS1U 
3A/100A 250V 
5A/100A 250V 
IEC 61058-1 
IEC 61058-1 
SEMKO 
SEMKO 
Mains switch 
(SW1) 
POSTEC Electric.  SDL1P-B 
5A/80A 250V 
IEC60065 
IEC61058-1 
VDE 
Enclosure Mtl. 
Top cover 
 
 
Front panel 
alt. 
 
Various 
 
 
Kumho Chemi. 
Various 
 
Various 
 
 
HFA-452 
Various 
 
Sheet Steel,  
Min. 0.80mm 
 
V-2, Min. 2.0mm
V-2 or better 
Min. 2.0mm thick
 

 
 
UL94 
UL94 
 
1.) 
 
 
UL, E65424 
UL 
PCB Various Various 
 Min. V-1, 130
°C UL 796 
UL 
Mains connector 
(CN91, CN92) 
Yeon Ho 
Electronics 
YW396 series 
(Wafer) 
Min. 5A/250V~ 
IEC60065 
1.) 
 
 
 
 
 
 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition 
 
Remarks 
 
 
 
 