Harman Kardon AVR 141 (serv.man3) EMC - CB Certificate ▷ View online
- Page 19 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.6.1 a)
Separate testing to IEC 61058 including:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ………………...:
- 10 000 operations
- Normal pollution suitability
- Resistance to heat and fire level 3
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1 ………………...:
Mains switch and relay provided.
Certified according to
IEC 61058-1.
- Mains switch, certified by VDE
- Mains relay, certified by
SEMKO.
See appended table,
list of critical components.
Certified according to
IEC 61058-1.
- Mains switch, certified by VDE
- Mains relay, certified by
SEMKO.
See appended table,
list of critical components.
P
14.6.1 b)
Tested in the apparatus …………….:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………….:
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1 ………………….:
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 ……………………………:
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1 ……………………………:
N/A
Switch controlling < 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………:
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1 ……………………………:
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ……...:
1 subclause 13.1 and has making/breaking action
independent of speed of actuation ……...:
Separately approved switch
and relay.
and relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ………………:
1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use ………………:
Separately approved switch
and relay.
and relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength ……………………………...….:
strength ……………………………...….:
Separately approved switch
and relay.
and relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1 ………….:
additional tests to IEC 60058-1 ………….:
The apparatus is not provided
the socket outlet, but measured
the apparatus surge through,
- Mains switch: < 1A peak
- Mains relay: 14 A peak
The measured inrush current
value is less than rated inrush
current rating of the mains
switch and relay. OK.
the socket outlet, but measured
the apparatus surge through,
- Mains switch: < 1A peak
- Mains relay: 14 A peak
The measured inrush current
value is less than rated inrush
current rating of the mains
switch and relay. OK.
P
Socket outlet current marking correct ……………..:
No mains socket-outlets
N/A
14.7
Safety interlocks
N/A
Safety interlocks to 2.8 of IEC 60950 ……………......:
No safety interlocks
N/A
- Page 20 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
14.8
Voltage setting devices and the like ……………….:
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally ……………………………......:
accidentally ……………………………......:
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors ………………….:
N/A
Motor start test ……………………………………:
N/A
Dielectric strength test …………………………:
N/A
14.9.2
Not adversely affected by oil or grease etc. …..:
N/A
14.9.3
Protection against moving parts …………..:
N/A
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ………………….:
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B ………………….:
Not such construction.
N/A
14.10 Batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases …………………………:
flammable gases …………………………:
No batteries
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries …………………………………:
batteries …………………………………:
N/A
14.10.3
Recharging currents and times within manufacturers
limits ……………………………………….:
limits ……………………………………….:
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits …………….:
within the manufacturers limits …………….:
N/A
14.10.4
Battery mould stress relief ………………….:
N/A
14.10.5
Battery drop test …………………………..:
N/A
14.11 Optocouplers
N/A
Optocouplers comply with Cl. 8 ……………:
No optocouplers
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation) ………………:
alternatively 13.6 (jointed insulation) ………………:
N/A
14.12
Surge suppression varistors
N/A
Comply with IEC 61051-2 …………………..:
No surge suppression varistors
N/A
Not connected between mains and accessible parts
except for earthed parts of permanently connected
apparatus …………………………….:
except for earthed parts of permanently connected
apparatus …………………………….:
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12 …..:
thermal stress requirements of 14.12 …..:
N/A
- Page 21 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
15 Terminals
15.1.1
Mains plug, appliance inlet, interconnection couplers
and mains socket-outlet meet the appropriate
standard ……………………………………………...:
and mains socket-outlet meet the appropriate
standard ……………………………………………...:
Approved mains plug and
socket-outlet provided,
See appended table, list of
critical components.
socket-outlet provided,
See appended table, list of
critical components.
P
Overloading of plugs or appliance inlets prevented if
the apparatus has mains socket outlets …………..:
the apparatus has mains socket outlets …………..:
No mains socket outlets
N/A
Overloading of internal wiring prevented if the
apparatus has mains socket outlets ……………….:
apparatus has mains socket outlets ……………….:
No mains socket outlets
N/A
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets ……….:
Only RCA, Antenna, Optical,
S-video, HDMI terminal used.
Banana plug type speaker
terminals also used, but they
are accepted due to below note
.
S-video, HDMI terminal used.
Banana plug type speaker
terminals also used, but they
are accepted due to below note
.
Note:
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
Banana plug type speaker
terminals are blocked in their
axial holes to prevent use of
plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2 ….......................:
marked with the symbol of 5.2 ….......................:
No sockets indicated with the
symbol
symbol
N/A
15.1.3
Output terminals of a.c. adaptors or similar devices
not compatible with household mains socket-outlets :
not compatible with household mains socket-outlets :
Not adaptors used
N/A
15.2
Provision for protective earthing
N/A
Accessible conductive parts of Class I equipment
reliably connected to earth terminal, within
equipment
reliably connected to earth terminal, within
equipment
Class II apparatus
N/A
Protective earth conductors correctly coloured ……..:
N/A
Equipment with non-detachable mains cord provided
with separate protective earth terminal near mains
input …...........................................................:
with separate protective earth terminal near mains
input …...........................................................:
N/A
Protective earth terminal resistant to corrosion ......:
N/A
Earth resistance test: < 0,1
Ω at 25 A …………….:
N/A
15.3
Terminals for external flexible cords and for
permanent connection to the mains supply
permanent connection to the mains supply
P
- Page 22 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.3.1
Adequate terminals for connection of permanent
wiring …………………………………...….:
wiring …………………………………...….:
Apparatus is not for permanent
connection.
connection.
N/A
15.3.2
Reliable connection of non-detachable cords …….:
P
Not soldered to conductors of a printed circuit board :
Not soldered
P
Adequate clearances and creepage distances
between connections should a wire break away …:
between connections should a wire break away …:
Wires are clamped two times
to the contact terminal and
provided with a two-pole
connector
to the contact terminal and
provided with a two-pole
connector
P
Wire secured by additional means to the
conductor ……………………………………:
conductor ……………………………………:
Adequately anchored.
Tested with 5 N.
Tested with 5 N.
P
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar …….:
adequate threads: ISO 261, ISO 262 or similar …….:
No screws and nuts clamping
N/A
15.3.4
Soldered conductors wrapped around terminal prior
to soldering or held in place by additional means …..:
to soldering or held in place by additional means …..:
No soldered conductors
N/A
Clamping of conductor and insulation if not soldered
or held by screws ………………………………:
or held by screws ………………………………:
Clamped insulators and
conductors
conductors
N/A
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of
the equipment ……………………….:
sectional area of conductors, for the rated current of
the equipment ……………………….:
Terminals have adequate
connection capacity.
connection capacity.
N/A
15.3.6
Terminals to 15.3.3 have sizes required by table 16:
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure ………………:
have adequate pressure ………………:
No clamps.
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened ………………..:
when tightened or loosened ………………..:
N/A
Terminals adequately fixed to avoid loosening when
the clamping is tightened or loosened and stress on
internal wiring is avoided ………………...................:
the clamping is tightened or loosened and stress on
internal wiring is avoided ………………...................:
N/A
15.3.8
Terminals carrying a current more than 0,2 A:
contact pressure not transmitted by insulating
material except ceramic ……………………….:
contact pressure not transmitted by insulating
material except ceramic ……………………….:
No contact pressure
transmitted through insulating
transmitted through insulating
P
15.3.9
Termination of non-detachable cords: wires
terminated near to each other ……………………...:
terminated near to each other ……………………...:
The termination of the contacts
are in adequate proximity to
each other.
are in adequate proximity to
each other.
P
Terminals located and shielded: test with 8 mm
strand ………………………………:
strand ………………………………:
Clamped contacts within
connector
connector
N/A
15.4
Devices forming a part of the mains plug
N/A