- Page 27 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 …………………..: 
No voltages exceeding 4kV,  
no fire enclosure requirement 
N/A 
20.2.2 
Internal fire enclosures with openings not exceeding 
1 mm in width and with openings for wires 
completely filled ……………………..: 
No internal fire enclosure. 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure ……………………….: 
No internal fire enclosure. 
N/A 
 
 
- Page 28 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
Annex A, Additional requirements for apparatus with protection against  
splashing water 
 
A.5 
Marking and instructions 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply ……………………………………………….....: 
Not intended for outdoor 
use. 
N/A 
A.10.2 Insulation 
requirements 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water.................................................................: 
 
N/A 
A.10.2.2 Humidity 
treatment 
carried out for 7 days …………: 
See clause above. 
N/A 
 
Annex B, Apparatus to be connected to the TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 ………………..: 
No TNV circuits 
N/A 
 
Complies with IEC 62151 clause 2 ………………..: 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard ……………...…: 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with annex 
B of this standard ……………………………: 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this standard
 
N/A 
 
Complies with IEC 62151 clause 6 ………………..: 
 
N/A 
 
Complies with IEC 62151 clause 7 ………………...: 
 
N/A 
 
Complies with IEC 62151 annex A, B and C ……...: 
 
N/A 
 
IEC 62151 clause 4.1.1:  
Add after the first paragraph: 
 
NOTE- In Finland, Norway and Sweden, class I equipment which 
is intended for connection to the building installation via a non-
industrial plug or a non-industrial appliance coupler or both and in 
addition is intended for connection to other equipment or a network 
shall, if safety relies on connection to protective earth or if surge 
suppressors are connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that the equipment 
must be connected to an earthed mains socket-outlet. 
 
The marking text in the applicable countries shall be as follow: 
-  Finland; ”Laite on liitettävä suojamaadoituskoskettimilla va 
 rustettuumpistorasiaan” 
-  Norway; ”Apparatet mǻ tikoples jordet stikkontakt” 
-  In Sweden; ”Apparaten skall anslutas till jordat uttag”
 
Class II apparatus 
N/A 
 
 
- Page 29 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
ANNEX L, Additional requirements for electronic flash apparatus for 
photographic purposes 
 
L. 5 
Marking and instructions 
N/A 
L. 5.4 
Instructions for battery chargers and Supply 
apparatus indicating type or model number of flash 
apparatus with which it is to be used ………………: 
No electronic flash apparatus. 
N/A 
 
Instructions for flash apparatus indicating type or 
model number of battery chargers or Supply 
apparatus with which it is to be used ………………: 
 
N/A 
L. 7 
Heating under normal operating conditions 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in  
Table 3, unless comply with 6.2.2.1.or 6.2.2.2 of  
IEC 60086-4 …………………………………………....:
No lithium batteries 
N/A 
L. 9 
Electric shock hazard under normal operating conditions 
N/A 
L. 9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE …………………………………: 
Not flash synchroniser. 
N/A 
L.10 Insulation 
requirements 
N/A 
L. 10.3.2 
High frequency pulse ignition………………………..:   
N/A 
L. 12 
Mechanical strength 
 
L. 12.1.3 
Windows for flash tubes are excluded from steel ball 
impact test ……………………………………………...:
 
N/A 
L. 14 
Components 
N/A 
L14.6.6 
Mains switch characteristics appropriate to its 
function under normal conditions …………………….:
 
N/A 
L. 20 
Resistance to fire 
N/A 
L. 20.1 c) 
Trigger coil for discharge purpose is not considered 
to be a POTENTIAL IGNITION SOURCE …………..:
 
N/A 
 
 
 
- Page 30 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by position of 
the functional switch (W)  
Less than 0.85W 
— 
Operating conditions 
Standby mode at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 0.004 0.80  — 
230 0.004 0.85  — 
Standby mode at 60Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
220 0.004 0.66  — 
230 0.004 0.70  — 
 
Measured at maximum non-clipped output at 50Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
2.42 
527 
2 x 50.0 W   (F) 
1 x 47.5 W   (C) 
2 x 47.0 W   (S) 
Measured at maximum non-clipped output at 60Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
2.37 
519 
2 x 50.0 W   (F) 
1 x 47.5 W   (C) 
2 x 47.0 W   (S) 
 
 
 
 
Tested condition: 1kHz input signal, connected 8 ohm loads for F, C, S channels 