Harman Kardon AVR 141 (serv.man3) EMC - CB Certificate ▷ View online
- Page 23 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.4.1
No undue strain on mains socket-outlets ……:
The apparatus is not a
device forming a part of the
mains plug.
device forming a part of the
mains plug.
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs ………………………………….:
mains plugs ………………………………….:
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c) ………………………………………….:
a,b,c) ………………………………………….:
N/A
16
External flexible cords
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic rubber
cords ……………………………………….:
IEC 60227 for PVC or IEC 60245 for synthetic rubber
cords ……………………………………….:
Sheathed PVC cord
complying with IEC 60227
complying with IEC 60227
P
Non-detachable cords for Class I have green/yellow
core for protective earth …………………………….:
core for protective earth …………………………….:
Class II apparatus
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment ………………………………………………:
sectional area for rated current consumption of the
equipment ………………………………………………:
The cord is 0.75mm²,
within the current rating.
within the current rating.
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength …………………………………:
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength …………………………………:
No interconnecting cables
comprising hazardous live
conductors.
comprising hazardous live
conductors.
N/A
b) Flexible cords not complying with 16.1, withstand
bending and mechanical stress (3.2 of IEC 60227-2):
bending and mechanical stress (3.2 of IEC 60227-2):
Cord complying with 16.1.
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions …………………………………….:
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions …………………………………….:
Cords have adequate cross-
sectional areas to avoid
temperature rise under normal
and fault conditions.
sectional areas to avoid
temperature rise under normal
and fault conditions.
P
16.5
Adequate strain relief on external flexible cords ….:
Cord clip wedged in the
enclosure
enclosure
P
Not possible to push cord back into equipment …..:
Checked by inspection
P
Strain relief device unlikely to damage flexible
cord ………………………………………:
cord ………………………………………:
No sharp edges
P
For mains cords of Class I equipment, hazardous
live conductors become taut before earth conductor :
live conductors become taut before earth conductor :
Class II apparatus.
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement in
use ………………………………:
damage to the cord during assembly or movement in
use ………………………………:
No sharp edges
N/A
- Page 24 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet to
IEC 60320-1 ……………………………………………:
fitted with detachable cord set with appliance inlet to
IEC 60320-1 ……………………………………………:
The apparatus is not a
transportable musical
instrument and amplifier
transportable musical
instrument and amplifier
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord ………………………...:
fitted with detachable cord sets or with means of
stowage to protect the cord ………………………...:
N/A
17
Electrical connections and mechanical fixings
17.1
Torque test to table 20
P
- screws into metal: 5 times …………………...:
(see appended table 17.1)
P
- screws into non-metallic material: 10 times ……..:
No non-metallic material
N/A
17.2
Correct introduction into female threads in non-
metallic material ………………………………..:
metallic material ………………………………..:
No female threads in
non-metallic materials
non-metallic materials
N/A
17.3
Cover fixing screws: captive …………………..:
Captivity not necessary
P
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter ….:
by a screw whose length is 10 times its diameter ….:
Tested with screw with 10 time
s
diameter.
s
diameter.
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A ………………………………………………..:
> 0,2 A ………………………………………………..:
Loosening is sufficiently
prevented
prevented
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A ………………………………………………..:
other than ceramic for connections carrying a current
> 0,2 A ………………………………………………..:
No contact pressure
transmitted through insulating
material.
transmitted through insulating
material.
P
17.6
Stranded conductors of flexible supply cords carrying
a current > 0,2 A with screw terminals not
consolidated by solder ………………………………:
a current > 0,2 A with screw terminals not
consolidated by solder ………………………………:
No screw terminals..
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous ………………………………………...:
adequate strength and their positioning is
unambiguous ………………………………………...:
No cover fixing devices other
than screws.
than screws.
N/A
17.8
Fixing devices for detachable legs or stands
provided ………………………………………………:
provided ………………………………………………:
No detachable provided.
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected …………………..:
unlikely to become disconnected …………………..:
Connections complies,
checked by inspection.
checked by inspection.
P
- Page 25 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
Picture tube separately approved to IEC 61965 ….:
No CRT in the equipment.
N/A
Picture tube separately approved to 18.1 .…….…….:
N/A
18.1
Picture tubes >16 cm intrinsically protected ……....:
N/A
Non-intrinsically protected tubes >16 cm used with
protective screen ..………………………………......:
protective screen ..………………………………......:
N/A
Protective film as part of implosion protection: edges
covered by enclosure ..…………………………...…:
covered by enclosure ..…………………………...…:
N/A
18.2
Intrinsically protected tubes: tests on 12 samples ..:
N/A
18.2.1
Samples subject to ageing: 6 samples ………………:
N/A
18.2.2
Samples subject to implosion test: 6 samples ……:
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6 samples ..…………………………………….:
ball): 6 samples ..…………………………………….:
N/A
18.3
Non-intrinsically protected tubes tested to 18.3 …..:
N/A
19
Stability and mechanical hazards
Mass of the equipment exceeding 7 kg..………….:
Weight: 8.7 kg
⎯
Apparatus intended to be fastened in place –
suitable instructions …………………………….….:
suitable instructions …………………………….….:
No.
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal….:
Tested on a plane inclined at
an angle of 10°
an angle of 10°
P
19.2
100 N force applied vertically downwards...….:
100N force have no influence
on the stability
on the stability
P
19.3
100 N force, or 13% of weight, applied horizontally to
point of least stability ….…………………….:
point of least stability ….…………………….:
< 25 kg, < 1M
N/A
19.4
Edges or corners not hazardous …………......:
There is no hazardous edges
or corners when the apparatus
is operating in normal position.
or corners when the apparatus
is operating in normal position.
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1 …………………………:
No glass surface.
N/A
19.6
Wall or ceiling mountings adequate ………………….:
Not intended for wall or ceiling
mounting.
mounting.
N/A
- Page 26 of 42 -
Report
No.
123035
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No. IEC60065_I
20
Resistance to fire
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width ……………:
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width ……………:
N/A
b) Exemption for small components as defined in
20.1 …………………………………………...:
20.1 …………………………………………...:
PCB is of flammability class
V-1 or better, and exception
is made for small components.
V-1 or better, and exception
is made for small components.
P
20.1.1 Electrical
components
meet the requirements of
Clause 14 or 20.1.4 …………………....:
Electrical components comply
with flammability requirements
in clause 14.
with flammability requirements
in clause 14.
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire ……………...:
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire ……………...:
No wires working at voltages
> 4kV or leaving an internal
fire enclosure
> 4kV or leaving an internal
fire enclosure
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure:
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC60707, unless used in a fire enclosure:
All PCB is of base material with
flammability category V-1.
See appended table, list of
critical components.
flammability category V-1.
See appended table, list of
critical components.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707 …….:
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707 …….:
No voltage exceeding 400V
(peak) a.c. or d.c.
(peak) a.c. or d.c.
N/A
20.1.4
Components and parts not covered by 20.1.1, 20.1.2
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21 ………………….:
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the
distances in Table 21 comply with the relevant
flammability category in Table 21 ………………….:
Bobbin of main and sub
transformer, rated 94V-0.
transformer, rated 94V-0.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13 ……………..:
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13 ……………..:
No such components.
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure ……………………………..…...:
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure ……………………………..…...:
Normal operating voltage
< 4KV
N/A