- Page 23 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
15.4.1 
No undue strain on mains socket-outlets ……: 
The apparatus is not a  
device forming a part of the 
mains plug. 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs ………………………………….: 
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c) ………………………………………….: 
 
N/A 
 
16 
External flexible cords 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic rubber 
cords ……………………………………….: 
Sheathed PVC cord  
complying with IEC 60227 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth …………………………….: 
Class II apparatus 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment ………………………………………………:
The cord is 0.75mm²,  
within the current rating. 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength …………………………………: 
No interconnecting cables  
comprising hazardous live  
conductors. 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2):
Cord complying with 16.1. 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions …………………………………….: 
Cords have adequate cross- 
sectional areas to avoid  
temperature rise under normal  
and fault conditions. 
16.5 
Adequate strain relief on external flexible cords ….: 
Cord clip wedged in the 
enclosure 
 
Not possible to push cord back into equipment …..: 
Checked by inspection 
 
Strain relief device unlikely to damage flexible  
cord ………………………………………: 
No sharp edges 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor :
Class II apparatus. 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement in 
use ………………………………: 
No sharp edges 
N/A 
 
 
- Page 24 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1 ……………………………………………:
The apparatus is not a  
transportable musical  
instrument and amplifier 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord ………………………...: 
 
N/A 
 
17 
Electrical connections and mechanical fixings 
 
17.1 
Torque test to table 20  
 
- screws into metal: 5 times …………………...: 
(see appended table 17.1) 
 
- screws into non-metallic material: 10 times ……..: 
No non-metallic material 
N/A 
17.2 
Correct introduction into female threads in non-
metallic material ………………………………..: 
No female threads in  
non-metallic materials 
N/A 
17.3 
Cover fixing screws: captive …………………..: 
Captivity not necessary 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter ….:
Tested with screw with 10 time

diameter. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A ………………………………………………..: 
Loosening is sufficiently 
prevented 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A ………………………………………………..: 
No contact pressure 
transmitted through insulating 
material. 
17.6 
Stranded conductors of flexible supply cords carrying 
a current > 0,2 A with screw terminals not 
consolidated by solder ………………………………: 
No screw terminals.. 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous ………………………………………...: 
No cover fixing devices other  
than screws. 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided ………………………………………………: 
No detachable provided. 
N/A 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected …………………..: 
Connections complies,  
checked by inspection. 
 
 
 
- Page 25 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
 
 
Picture tube separately approved to IEC 61965 ….: 
No CRT in the equipment. 
N/A 
 
Picture tube separately approved to 18.1 .…….…….:
 
N/A 
18.1 
Picture tubes >16 cm intrinsically protected ……....: 
 
N/A 
 
Non-intrinsically protected tubes >16 cm used with 
protective screen ..………………………………......: 
 
N/A 
 
Protective film as part of implosion protection: edges 
covered by enclosure ..…………………………...…: 
 
N/A 
18.2 
Intrinsically protected tubes: tests on 12 samples ..: 
 
N/A 
18.2.1 
Samples subject to ageing: 6 samples ………………:
 
N/A 
18.2.2 
Samples subject to implosion test: 6 samples ……: 
 
N/A 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 samples ..…………………………………….: 
 
N/A 
18.3 
Non-intrinsically protected tubes tested to 18.3 …..: 
 
N/A 
 
19 
Stability and mechanical hazards 
 
 
Mass of the equipment exceeding 7 kg..………….: 
Weight: 8.7 kg 
 
 
Apparatus intended to be fastened in place – 
suitable instructions …………………………….….: 
No. 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal….: 
Tested on a plane inclined at  
an angle of 10° 
19.2 
100 N force applied vertically downwards...….: 
100N force have no influence 
on the stability 
19.3 
100 N force, or 13% of weight, applied horizontally to 
point of least stability ….…………………….: 
< 25 kg, < 1M 
N/A 
19.4 
Edges or corners not hazardous …………......: 
There is no hazardous edges  
or corners when the apparatus  
is operating in normal position. 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension > 450 mm, 
pass the test of 19.5.1 …………………………: 
No glass surface. 
N/A 
19.6 
Wall or ceiling mountings adequate ………………….:
Not intended for wall or ceiling  
mounting. 
N/A 
 
 
- Page 26 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
IEC 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065_I 
 
 
 
20 
Resistance to fire 
 
20.1 
Electrical components and mechanical parts  
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width ……………: 
 
N/A 
 
b) Exemption for small components as defined in 
20.1 …………………………………………...: 
PCB is of flammability class  
V-1 or better, and exception  
is made for small components. 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 …………………....: 
Electrical components comply 
with flammability requirements 
in clause 14. 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire ……………...: 
No wires working at voltages  
> 4kV or leaving an internal  
fire enclosure 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC60707, unless used in a fire enclosure: 
All PCB is of base material with 
flammability category V-1.  
See appended table, list of  
critical components. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 …….: 
No voltage exceeding 400V 
(peak) a.c. or d.c. 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 20.1.2 
and 20.1.3 (other than fire enclosures) mounted 
nearer to a potential ignition source than the 
distances in Table 21 comply with the relevant 
flammability category in Table 21 ………………….: 
Bobbin of main and sub  
transformer, rated 94V-0. 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 ……………..: 
No such components. 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure ……………………………..…...: 
Normal operating voltage  
< 4KV  
N/A 
Page of 80