Harman Kardon AVR 141 (serv.man3) EMC - CB Certificate ▷ View online
- Page 35 of 42 -
Report
No.
123035
TRF No. IEC60065_I
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault condi-
tions (
o
C)
Min T softening
(
o
C)
Mains connector (CN91)
19.6 (43.9 °C)
(I/P=253V, ambient
24.3 °C)
(I/P=253V, ambient
24.3 °C)
29.4 (52.8 °C)
(I/P=253V, ambient
23.4 °C)
(I/P=253V, ambient
23.4 °C)
> 200
(type, YW396 series)
Mains connector (CN92)
20.7 (45.0 °C)
(I/P=253V, ambient
24.3 °C)
(I/P=253V, ambient
24.3 °C)
33.0 (56.4 °C)
(I/P=253V, ambient
23.4 °C)
(I/P=253V, ambient
23.4 °C)
> 200
(type, YW396 series)
9.1.1.1
Touch current expressed as voltages U1 and U2 in Annex D
P
Location
Measured
U1V (peak)
U1V (peak)
Measured
U1 V (DC)
U1 V (DC)
Measured
U2 V (peak)
U2 V (peak)
Limits :
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
U1 Max 35V (peak)
U1 Max 1.1V (DC)
U2 Max 0.35V (peak)
Pole 1 - Antenna terminal
Pole 2 - Antenna terminal
Pole 2 - Antenna terminal
-
-
-
-
-
-
0.06V peak
0.07V peak
0.07V peak
Pass
Pass
Pass
Pole 1 - other part or contact
Pole 2 - other part or contact
Pole 2 - other part or contact
-
-
-
-
-
-
0.06V peak
0.07V peak
0.07V peak
Pass
Pass
Pass
Comments:
Vin = 253Vac
Only U2 have been recorded due to the use of a linear transformer in power supply.
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
> 100 Min
2
Between parts separated by double or reinforced insulation
> 100 Min
4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500Vac
No
Between parts separated by double or reinforced insulation
3000Vac
No
- Page 36 of 42 -
Report
No.
123035
TRF No. IEC60065_I
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
207V or 253V
—
Ambient temperature (
o
C) ...................................... :
24-27
o
C
—
Monitored point:
Under fault conditions
specified below
dT (K)
Permitted
dT (K)
1. *), D111 (A to C), SC, 10 min;
Output signal off immediately. FI stabilised at 0.42A.
R104 and R105 opened. No hazard.
Output signal off immediately. FI stabilised at 0.42A.
R104 and R105 opened. No hazard.
N/A N/A
2. *), D114 (A to C), SC, 25 min;
Output signal normal operated. FI stabilised at 1.10A.
R105 opened. No hazard.
Output signal normal operated. FI stabilised at 1.10A.
R105 opened. No hazard.
N/A N/A
3. *), D103 (A to C), SC, 10 min;
Output signal normal operated. FI stabilised at 1.10A.
R107 opened. No hazard.
Output signal normal operated. FI stabilised at 1.10A.
R107 opened. No hazard.
N/A N/A
4. *), D106 (A to C), SC, 10 min;
Output signal normal operated. FI stabilised at 1.10A.
R106 opened. No hazard.
Output signal normal operated. FI stabilised at 1.10A.
R106 opened. No hazard.
N/A N/A
5. *), C110, SC, 10 min;
Output signal off immediately. FI stabilised at 0.35A.
R106 and R107 opened. No hazard.
Output signal off immediately. FI stabilised at 0.35A.
R106 and R107 opened. No hazard.
N/A N/A
6. *), C117, SC, 10 min;
Output signal normal operated. FI stabilised at 1.10A.
NCD. No hazard.
Output signal normal operated. FI stabilised at 1.10A.
NCD. No hazard.
N/A N/A
7. *), C122, SC, 10 min;
FL display off immediately. FI stabilised at 1.09A.
R101 opened. No hazard.
FL display off immediately. FI stabilised at 1.09A.
R101 opened. No hazard.
N/A N/A
8. *), C930, SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
R104 and R105 opened. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
R104 and R105 opened. No hazard.
N/A N/A
9. *), C929, SC, 10 min;
Output signal off immediately. FI stabilised at 0.42A.
R104 and R105 opened. No hazard.
Output signal off immediately. FI stabilised at 0.42A.
R104 and R105 opened. No hazard.
N/A N/A
10. *), C941, SC, 40 min;
FL display and output signal off immediately. FI stabilised at 0.35A.
R106 and R107 opened. No hazard.
FL display and output signal off immediately. FI stabilised at 0.35A.
R106 and R107 opened. No hazard.
N/A N/A
11. *), D991 (AC to +), SC, 1 sec;
F901 opened immediately. FI stabilised at 0.01A.
No hazard.
F901 opened immediately. FI stabilised at 0.01A.
No hazard.
N/A N/A
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
- Page 37 of 42 -
Report
No.
123035
TRF No. IEC60065_I
Monitored point:
Under fault conditions specified below- continued
dT (K)
Permitted
dT (K)
12. **), D991 (AC to -), SC, 2 sec;
Unit shut down after 2 sec. FI stabilised at 0.01A.
NCD. No hazard.
Unit shut down after 2 sec. FI stabilised at 0.01A.
NCD. No hazard.
N/A N/A
13. **), C915, SC, 1 sec;
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
N/A N/A
14. *), C916, SC, 3 sec;
Unit shut down after 3 sec. FI stabilised at 0.01A.
NCD. No hazard.
Unit shut down after 3 sec. FI stabilised at 0.01A.
NCD. No hazard.
N/A N/A
15. *), Q603 (E to C), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
Q604 and R810 damaged. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
Q604 and R810 damaged. No hazard.
N/A N/A
16. *), Q603 (C to B), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
N/A N/A
17. *), Q604 (E to C), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
Q603 and R810 damaged. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
Q603 and R810 damaged. No hazard.
N/A N/A
18. *), Q604 (C to B), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
NCD. No hazard.
N/A N/A
19. *), C807, SC, 10 min;
SL-ch. output signal off immediately. FI stabilised at 0.95A.
R621 opened. No hazard.
SL-ch. output signal off immediately. FI stabilised at 0.95A.
R621 opened. No hazard.
N/A N/A
20. *), C808, SC, 10 min;
SL-ch. output signal off immediately. FI stabilised at 0.95A.
R822 opened. No hazard.
SL-ch. output signal off immediately. FI stabilised at 0.95A.
R822 opened. No hazard.
N/A N/A
21. *), D962 (A to C), SC, 4 hr;
Output signal normal operated, FI stabilised at 1.12A.
Sub transformer winding maximum temperature 60.8K and stabilised.
Dielectric strength test O.K.. No hazard.
Output signal normal operated, FI stabilised at 1.12A.
Sub transformer winding maximum temperature 60.8K and stabilised.
Dielectric strength test O.K.. No hazard.
Sub transf.
60.8
Sub transf.
150
22. *), C906, SC, 3 hr;
Unit shut down immediately. FI stabilised at 0.02A.
Sub transformer winding maximum temperature 62.3K and stabilised.
Dielectric strength test O.K.. No hazard.
Unit shut down immediately. FI stabilised at 0.02A.
Sub transformer winding maximum temperature 62.3K and stabilised.
Dielectric strength test O.K.. No hazard.
Sub transf.
62.3
Sub transf.
150
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
- Page 38 of 42 -
Report
No.
123035
TRF No. IEC60065_I
Monitored point:
Under fault conditions specified below- continued
dT (K)
Permitted
dT (K)
23. *), Speaker output (Front-R channel), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.01A.
NCD, No hazard.
Unit shut down immediately. FI stabilised at 0.01A.
NCD, No hazard.
N/A N/A
24. *), Ventilation opening (Blocked), 30 min;
Unit shut down after 30 min.
The components are maximum temperature:
1) Main transformer primary winding
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PWB near D991
FI stabilised at 0.01A. Dielectric strength test O.K.. No hazard.
Unit shut down after 30 min.
The components are maximum temperature:
1) Main transformer primary winding
2) Main transformer core
3) Sub transformer primary winding
4) Sub transformer core
5) PWB near D991
FI stabilised at 0.01A. Dielectric strength test O.K.. No hazard.
1) 69.2
2) 55.2
3) 39.4
4) 35.4
5) 58.2
2) 55.2
3) 39.4
4) 35.4
5) 58.2
1) 150
2) 150
3) 150
4) 150
5) 110
2) 150
3) 150
4) 150
5) 110
25. *), Pmax. Operating (Maximum non-clipped output signal), 22 min;
Main transformer winding heated up to 144.7K and thermal fuse opened
after 22 min. FI stabilised at 0.01A. Dielectric strength test O.K.. No hazard.
Main transformer winding heated up to 144.7K and thermal fuse opened
after 22 min. FI stabilised at 0.01A. Dielectric strength test O.K.. No hazard.
Main transf.
144.7
Main transf.
150
*) Tested at 253V
**) Tested at 207V
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current