- Page 4 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
Annex ZA 
(normative) 
Other international publications quoted in this standard with the references 
of the relevant European publications 
This European Standard incorporates by dated or undated reference, provisions 
from other publications. These normative references are cited at the appropriate 
places in the text and the publications are listed hereafter. For dated references, 
subsequent amendments to or revisions of any of these publications apply to this 
European Standard only when incorporated in it by amendment or revision. For 
undated references the latest edition of the publication referred to applies 
(including amendments). 
 
NOTE When an international standard has been modified by common 
modification, indicated by (mod), the relevant EN/HD applies. 
 
 
 
 
- Page 5 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
Annex ZA 
Cont. 
 
 
 
 
- Page 6 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
Annex ZA 
Cont. 
 
GROUP DIFFERENCES FOR AMENDMENT 1 
COMMON MODIFICATIONS 
N/A 
5.1 i) 
in EN 60065:2002 
Replace 
the note by: 
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is 
made to EN 62087. Measurements are done in the ON (play) operating mode. 
N/A 
5.4.1 
 
Add the following indent: 
za) A warning that excessive sound pressure from earphones and headphones  
can cause hearing loss. 
N/A 
6.1 
 
 
6.1 
in EN 60065:2002 
Replace 
the subclause by: 
Ionizing radiation 
Equipment that might produce ionizing radiation is checked by measuring the amount 
of radiation. 
The amount of radiation is determined by means of a radiation monitor of the ionizing 
chamber type with an effective area of 1 000 mm2 or by measuring equipment of 
other types giving equivalent results. 
Measurements are made with the equipment on test operating at the most  
unfavourable supply voltage (see 4.2) and with operator controls and service controls 
adjusted so as to give maximum radiation whilst maintaining the equipment operative  
for normal use. 
Internal preset controls not intended to be adjusted during the lifetime of the 
equipment are not considered to be service controls. 
At any point 100 mm from the surface of the operator access area, the dose-rate shall 
not exceed 1 
μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background 
level. 
NOTE These values appear in Directive 96/29/Euratom. 
N/A 
 
 
- Page 7 of 10 - 
 
 
 
 
 Report 
No. 
123035 
 
ATTACHMENT 3 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065_I 
Bibliogra
phy in 
EN 
60065:20
02 
 
Replace the paragraph related to prEN 50332-2 by: 
EN 50332-2:2003, Sound system equipment: Headphones and earphones 
associated with portable audio equipment - Maximum sound pressure level 
measurement methodology and limit considerations - Part 2: Matching of 
sets with headphones if either or both are offered separately EN 
60065:2002/A1:2006 - 4 - 
N/A 
Bibliogra
phy in IEC 
60065:200
1/A1:2005 
Add the following notes for the standards indicated: 
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994 
 (not modified). 
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991  
(not modified). 
N/A 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) 
 
2.6.1 
DK: The following is added: 
Certain types of CLASS I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Justification: Heavy Current Regulations, Section 
107. 
Class II apparatus 
N/A 
13.3.1 
NO: To the second paragraph the following is 
added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
Noted 