DOWNLOAD Harman Kardon AVR 141 (serv.man3) Service Manual ↓ Size: 2.2 MB | Pages: 80 in PDF or view online for FREE

Model
AVR 141 (serv.man3)
Pages
80
Size
2.2 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-141-sm3.pdf
Date

Harman Kardon AVR 141 (serv.man3) EMC - CB Certificate ▷ View online

 
 
- Page 31 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
 
Measured at 1/8 of maximum non-clipped output at 50Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 1.15 
#) 1.11 
226.3 
#) 219.0 
 
 
 
 
 
2 x 6.25 W   (F) 
1 x 5.94 W   (C) 
2 x 5.88 W   (S) 
 
 
 
 
242 1.14 
#) 1.10 
214.4 
#) 208.3 
230 1.12 
#) 1.08 
201.8 
#) 195.7 
220 1.11 
#) 1.07 
191.0 
#) 184.6 
198 1.06 
#) 1.04 
166.7 
#) 163.1 
Measured at 1/8 of maximum non-clipped output at 60Hz: 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 1.13 
#) 1.10 
223.7 
#) 215.8 
 
 
 
 
 
2 x 6.25 W   (F) 
1 x 5.94 W   (C) 
2 x 5.88 W   (S) 
 
 
 
 
242 1.12 
#) 1.09 
212.4 
#) 207.2 
230 1.10 
#) 1.07 
199.8 
#) 194.3 
220 1.09 
#) 1.06 
190.4 
#) 183.4 
198 1.06 
#) 1.03 
167.7 
#) 162.8 
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads connected condition, and 
then replaced the input signal to pink noise for heating and fault condition tests. 
The values followed #)  in table above are measured “A” or “W” value, when replaced the input signal 
from 1 kHz sign wave to pink noise. 
 
Loudspeaker impedance (Ω) : 
8 Ohms 
— 
 
Several loudspeaker systems 
Right and Left for Front, 
Only one for Center, 
Right and Left for Surround channels. 
 
Marking of loudspeaker terminals
SPEAKERS (8
Ω): FRONT, CENTER,  
SURR. 
 
 
- Page 32 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
7.1 
TABLE: temperature rise measurements 
Monitored point: 
dT (K) at  
253V, 50Hz
dT (K) at  
198V, 50Hz
dT (K) at  
253V, 60Hz
dT (K) at  
198V, 60Hz 
Permitted 
dT (K) *) 
Main transformer core 
58.9  
49.4  
58.8  
46.6  
95 
Sub-transformer core 
29.4  
24.1  
29.5  
23.4  
85 
CN92 connector 
20.7  
17.5  
20.7  
17.5  
CN91 connector 
19.4  
16.5  
19.6  
16.5  
D991 heat-sink 
66.7  
62.6  
67.6  
62.5  
PWB near D991 
45.9  
41.5  
46.4  
41.6  
70 
C915 capacitor body  
27.8  
25.2  
28.3  
25.4  
85 
°C 
Q603 body 
69.1  
47.7  
69.8  
48.2  
PWB near Q603 
49.6  
36.1  
50.7  
36.4  
70 
PWB near Q604 
55.7  
40.0  
55.9  
40.6  
70 
Main heat-sink 
60.3  
42.5  
60.6  
43.0  
Stand-by Switch (non-metallic) 
1.6  
0.9  
1.4  
1.5  
50 
Top enclosure above transformer 
22.6  
19.7  
23.2  
19.5  
40 
Top enclosure above main heat-sink 
34.2  
24.6  
34.2  
25.3  
65 **) 
Front panel (non-metallic) 
11.4  
8.8  
12.6  
9.1  
 
 
 
 
 
 
*)   Temperature rise limits for Singapore is 10K less 
**)   Directly covering part for main heat-sink. The top cover is supplied with ventilation openings covering 
  
most of the top cover. This indicates emission of heat from internal parts and the opening area is 
 
therefore not likely to be touched during normal use. 
 
 
 
- Page 33 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
 
Winding temperature rise 
measurements 
253V/50Hz 253V/60Hz 198V/50Hz 198V/60Hz 
— 
 
Ambient temperature t1 (
o
C) : 
23.0 23.0 23.0 23.0  — 
 
Ambient temperature t2 (
o
C) : 
23.7 24.3 24.2 25.1  — 
Temperature rise dT of winding: 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Permitted 
dT (K) *) 
Insulation 
class 
Main transf. primary winding (253V, 50Hz) 
4.84 
6.33 
78.6 
95 
Sub transf. primary winding (253V, 50Hz) 
4411 5068  37.7  85 
 
 
 
 
 
 
Main transf. primary winding (253V, 60Hz) 
4.84 
6.32 
77.4 
95 
Sub transf. primary winding (253V, 60Hz) 
4411 5081  37.8  85 
 
 
 
 
 
 
Main transf. primary winding (198V, 50Hz) 
4.84 
6.12 
66.9 
95 
Sub transf. primary winding (198V, 50Hz) 
4411 4973  31.6  85 
 
 
 
 
 
 
Main transf. primary winding (198V, 60Hz) 
4.84 
6.11 
65.5 
95 
Sub transf. primary winding (198V, 60Hz) 
4411 4973  30.7  85 
 
 
 
 
 
 
*) Temperature rise limits for Singapore is 10K less 
 
 
 
 
- Page 34 of 42 - 
 
 
 
 
 Report 
No. 
123035 
 
TRF No. IEC60065_I 
7.1 
TABLE: temperature rise measurements 
Monitored point: 
 
 
dT (K) at  
242V, 60Hz
dT (K) at  
198V, 60Hz 
Permitted 
dT (K) 
Main transformer core 
 
 
57.1  
46.6  
95 
Sub-transformer core 
 
 
28.3  
23.4  
85 
CN92 connector 
 
 
20.0  
17.5  
CN91 connector 
 
 
19.0  
16.5  
D991 heat-sink 
 
 
66.4  
62.5  
PWB near D991 
 
 
45.4  
41.6  
70 
C915 capacitor body  
 
 
27.6  
25.4  
85 
°C 
Q603 body 
 
 
65.3  
48.2  
PWB near Q603 
 
 
47.8  
36.4  
70 
PWB near Q604 
 
 
52.9  
40.6  
70 
Main heat-sink 
 
 
56.9  
43.0  
Stand-by Switch (non-metallic) 
 
 
1.6  
1.5  
50 
Top enclosure above transformer 
 
 
22.4  
19.5  
40 
Top enclosure above main heat-sink   
 
32.2  
25.3  
40 
Front panel (non-metallic) 
 
 
12.1  
9.1  
 
 
 
 
 
 
 
 
Winding temperature rise measurements 
 
242V/60Hz 198V/60Hz
 
— 
 
Ambient temperature t1 (
o
C) : 
  
23.0 
23.0 
— 
 
Ambient temperature t2 (
o
C) : 
  
24.2 
25.1 
— 
Temperature rise dT of winding:
 
R
1
 (Ω) 
R
2
 (Ω) 
dT (K) 
Permitted 
dT (K) 
Insulation 
class 
Main transf. primary winding (242V, 60Hz) 
4.84 
6.29 
75.9 
95 
Sub transf. primary winding (242V, 60Hz) 
4411 5049 36.0  85 
 
 
 
 
 
 
Main transf. primary winding (198V, 60Hz) 
4.84 
6.11 
65.5 
95 
Sub transf. primary winding (198V, 60Hz) 
4411 4973 30.7  85 
 
 
 
 
 
 
 
Page of 80
Display