Movie / SECTION 6 ADJUSTMENTS
File
hdr-sr11-hdr-sr11e-hdr-sr12-hdr-sr12e-sm3.pdf
Date

Sony HDR-SR11 / HDR-SR11E / HDR-SR12 / HDR-SR12E (serv.man3) Service Manual ▷ View online

6-24
HDR-SR11/SR11E/SR12/SR12E_ADJ
5.
CAMERA Adjustment 2
(Using the flange back adjustment chart and
subject more than 500 m away)
5-1. CAMERA Adjustment 2 (1)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (1) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Place the Flange back adjustment chart at 2 m position away
from the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
[Adjusting method]
1) Click the [Start $1%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (1) Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2 (1), the following message is displayed. Click
the [OK] button.
6) Perform “CAMERA Adjustment 2 (2)”.
5-2. CAMERA Adjustment 2 (2)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (2) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
[Adjusting method]
1) Click the [Start $2%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (2) Adj.” will be
executed.
The following message is displayed during the execution of
adjustment, and then place the ND filter on the lens so as to
obtain the optimum image.
5) If “2. Flange Back (2) Adj.” completed successfully, “3. Re-
lease of Data Setting during Camera Adj.” will be executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2 (2), the following message is displayed. Click
the [OK] button.
6-25
HDR-SR11/SR11E/SR12/SR12E_ADJ
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) If the [OK] button is clicked, “2. Flange Back Check” is ex-
ecuted. The following messages are displayed, and then oper-
ate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK] button.
7.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. F No. & ND Light Quality Standard Data Input.
2. Mechanical Shutter Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes “1. F No. & ND
Light Quality Standard Data Input” and “2. Mechanical Shut-
ter Adj.”.
3) Upon successful completion of all items of the CAMERA Ad-
justment 4, the following message is displayed. Click the [OK]
button.
6-26
HDR-SR11/SR11E/SR12/SR12E_ADJ
8.
CAMERA Adjustment 5
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Linear Matrix Adj.
3. Picture Frame Setting (Color Reproduction Adjustment Frame)
4. Picture Frame Setting (All White Frame)
5. AWB Standard Data Input
6. LV Standard Data Input
7. AWB Adj.
8. AWB Check
9. Color Reproduction Adj. & Check (Indoor)
10. Color Reproduction Check (Outdoor)
11. Picture Frame Setting (Center Frame)
12. MAX GAIN Adj.
13. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items “2. Linear Matrix Adj.” will be executed.
4) Upon successful completion of the “2. Linear Matrix Adj.”,
the following screen is displayed during the execution of “3.
Picture Frame Setting (Color Reproduction Adjustment
Frame)”. Set the subject in accordance with the message.
5) If the [OK] button is clicked, the following screen will appear,
and then adjust the zoom and the camera direction to set the
picture frame. After the setting finished, click the [End] but-
ton.
The buttons on this screen provide the following functions:
[Save the position] button
Saves the camera zoom and focus position data.
[Load the position] button
Reads the camera zoom and focus position data saved last and
moves the camera zoom and focus to that position.
Note 1:
The zoom and focus position data are saved with
“HDR_SR11_ZoomFocusData.txt” file name in the same
holder as the Automatic Adjustment Program.
No position data can be read if this file is moved or de-
leted.
Note 2:
Only the latest position data can be saved. If the [Save
the position] button is clicked, the latest data are saved
over writing the previous data.
6-27
HDR-SR11/SR11E/SR12/SR12E_ADJ
6) After setting the picture frame, if the [End] button is clicked,
“4. Picture Frame Setting (All White Frame)” is executed. The
following messages are displayed in the order given below
during the execution. Then, set the picture frame in accordance
with the messages.
7) After the setting, if the [OK] button is clicked, the adjustment
items from “5. AWB Standard Data Input” to “8. AWB Check”
are executed. During the execution, the following messages
are displayed in the order given below. Place or remove the
filters on the lens in accordance with the messages.
8) Upon successful completion of the “8. AWB Check”, the fol-
lowing message is displayed. Then, change the chart in accor-
dance with the message.
9) If the [OK] button is clicked, the adjustment items “9. Color
Reproduction Adj. & Check (Indoor)” is executed.
10) After the checking of the Indoor mode, “10. Color Reproduc-
tion Check (Outdoor)” is executed. The following messages
are displayed in order given below. Place or remove the filters
on the lens in accordance with the messages.
11) Upon successful completion of the “10. Color Reproduction
Check (Outdoor)”, the following message is displayed. Then,
change the chart in accordance with the message.
12) After the setting, if the [OK] button is clicked, the following
message is displayed during the execution of “11. Picture Frame
Setting (Center Frame)”. Set the subject in accordance with
the message, and then check the size of clear chart shot on the
monitor screen.
Page of 48