DOWNLOAD Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ↓ Size: 857.39 KB | Pages: 96 in PDF or view online for FREE

Model
HDR-HC9 HDR-HC9E (serv.man4)
Pages
96
Size
857.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-56
HDR-HC9/HC9E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
7
01
7E
4
7
04
01
5
7
00
01
Press PAUSE (Write) button.
6
6
9C
01
7
6
01
67
Press PAUSE (Write) button.
8
6
02
Check the data changes to
“01”.
9
6
0C
Check the data is “00”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
7
01
7E
3
7
04
00
4
7
00
01
Press PAUSE (Write) button.
5
6
9C
00
6
0
01
00
31. Strobe Light Level Adjustment 
RadarW
RadarW
RadarW
Adjust the strobe light level.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
69
Adjustment Address
B8 to BD
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Hall Adjustment” , “Flange Back Adjustment”,
“F No, & ND Light Quality Standard Data Input” and
“Auto White Balance Adjustment” before this adjustment.
Note 2:
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”. (See
page 6-7)
Note 4:
If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
How to reset the flash error flag
When the flash error code (E:91: ** ) is displayed. After repair,
clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”.
6-57
HDR-HC9/HC9E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 6)
3
7
01
7E
4
7
04
01
5
7
00
01
Press PAUSE (Write) button.
6
6
9C
01
7
6
A8
01
8
6
01
B9
Press PAUSE (Write) button.
(Note 7
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
11
Wait for 3 seconds.
12
6
01
E7
Press PAUSE (Write) button.
13
6
02
Check the data changes to
“01”.
14
6
0C
Check the data is “00”.
Note 6:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 7:
The adjustment data will be automatically input to page:
6F, address: 80, 81.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
7
01
7E
3
7
04
00
4
7
00
01
Press PAUSE (Write) button.
5
6
9C
00
6
6
A8
00
7
0
01
00
32. Strobe White Balance Adjustment 
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
80, 81
Specified value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Hall Adjustment”, “Flange Back Adjustment”,
“F No, & ND Light Quality Standard Data Input” , “Auto
White Balance Adjustment” and “Strobe Light Level Ad-
justment” before this adjustment.
Note 2:
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”. (See
page 6-7)
Note 4:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Note 5:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) FLASH ................................................................. Forced flash
(Press the FLASH button and set to the forced flash mode.)
How to reset the flash error flag
When the flash error code (E:91: ** ) is displayed. After repair,
clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”.
6-58
HDR-HC9/HC9E_ADJ
33. Angular Velocity Sensor Sensitivity Adjustment
Adjust the gain to eliminate the output dispersion Angular veloc-
ity sensor.
Perform this adjustment when the lens block is replaced, CM-077
board is replaced, or Hall sensor is adjusted.
Do not perform this adjustment and check the Steady Shot opera-
tion only, if the microcomputer or board other than this lens block
failed.
33-1. Preparation when the angular velocity sensor or
the CM-077 board is replaced
Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it was
attached to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Page
7F
Adjustment Address
12, 13
Note 1:
The sensor sensitivity of SE7201 and SE7202 of the CM-
077 board is written only repair parts.
Preparation:
1) Read the PITCH sensor (CM-077 board SE7202) sensitivity
written on repair parts, and named this as P12.
2) Read the YAW sensor (CM-077 board SE7201) sensitivity writ-
ten on repair parts, and named this as Y12.
Fig. 6-1-22 (1)
Note 2:
Only the value of decimal places has been written to the
angular velocity sensor.
How to read the sensitivity data of angular velocity sen-
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
Fig. 6-1-22 (2)
33-2. Preparation when the lens is replaced
Note down the PITCH/YAW data on the replacement lens for repair.
Adjustment Page
7F
Adjustment Address
12, 13
Note:
The PITCH/YAW data of lens is written only repair parts.
Preparation:
1) Read the PITCH data written on repair parts, and named this
as L
1
.
2) Read the YAW data written on repair parts, and named this as
L
2
.
Fig. 6-1-23
YAW data    
t
 L
2
PITCH/YAW Data
PITCH data 
t
 L
1
X.XX / X.XX
SE7202
SE7201
12
43
1
2
4
3
CM-077 BOARD (SIDE A)
PP
YY
YAW sensor sensitivity    
t
 Y12
PITCH sensor sensitivity 
t
 P12
For the sensor sensitivity value 60
6 0
Hand Writing
1
2
4
3
Description example :
6-59
HDR-HC9/HC9E_ADJ
33-3. Angular Velocity Sensor Sensitivity Adjustment
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Using the following formula
calculate:
Gain adjustment value of
angular velocity sensor in
pitch direction D
12’
 (decimal
number)
Gain adjustment value of
angular velocity sensor in
yaw direction D
13’ 
(decimal
number)
(Note 1)
D
12’
= 95 
×
 P12 
×
 L
1
D
13’
= 95 
×
 Y12 
×
 L
2
3
Convert D
12’
 and D
13’
 into
hexadecimal numbers and
assume them as D
12 
and D
13
respectively. (Note 2, 3)
4
0
10
07
5
F
12
D
12
Press PAUSE (Write) button.
(7F)
6
F
13
D
13
Press PAUSE (Write) button.
(7F)
7
0
10
00
8
0
01
00
Note 1:
If the gain data of angular velocity sensor is not avail-
able, perform calculation with P12=Y12=0.6.
Also, if the lens data is not available, perform calcula-
tion with L
1
=L
2
=1.
Note 2:
Round off the decimal places of the calculation results.
Note 3:
Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
Turn off the power and turn
on again.
2
0
01
01
3
0
10
07
4
F
12
D
12
Check that the data D
12
 is
(7F)
reflected correctly.
5
F
13
D
13
Check that the data D
13
 is
(7F)
reflected correctly.
6
0
10
00
7
Check that the steady shot
operates normally when it is
turned on.
8
0
01
00
Page of 96
Display