DOWNLOAD Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ↓ Size: 857.39 KB | Pages: 96 in PDF or view online for FREE

Model
HDR-HC9 HDR-HC9E (serv.man4)
Pages
96
Size
857.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-48
HDR-HC9/HC9E_ADJ
21. Color Reproduction Check (Outdoor HD) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Video terminal of
Adjusting
A/V jack
remote
(75 
 
terminated) commander
Measuring Instrument
Vectorscope
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”.
settle within each
color
reproduction
frame.
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Fig. 6-1-18
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
Perform “18. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.
2
Place the C14 filter on the
lens.
3
0
01
01
4
7
01
BD
5
7
00
01
Press PAUSE (Write) button.
6
6
9B
Check the bit value of bit 2, 3
is “0”. (Note 3)
7
6
02
Check the data is “00”.
(Note 4)
8
6
C9
10
9
6
CA
0C
10
6
D0
59
11
6
01
3D
Press PAUSE (Write) button.
12
6
02
Check the data changes to
“01”.
13
6
0C
Check the data is “00”.
14
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst luminance
point to the burst
position of color reproduc
tion frame.
15
Check that the each color
luminance point is in each
color reproduction frame.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
D0
00
3
6
CA
00
4
6
C9
00
5
0
01
00
6
Remove the C14 filter on the
lens.
HDR-HC9
HDR-HC9E
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst position
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst position
6-49
HDR-HC9/HC9E_ADJ
22. Color Reproduction Check (Outdoor SD) 
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Video terminal of
Adjusting
A/V jack
remote
(75 
 
terminated) commander
Measuring Instrument
Vectorscope
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”
settle within each
color
reproduction
frame.
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
HDR-HC9
HDR-HC9E
Fig. 6-1-19
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
Perform “18. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.
2
Place the C14 filter on the
lens.
3
0
01
01
4
7
01
BE
5
7
00
01
Press PAUSE (Write) button.
6
6
9B
Check the bit value of bit 2 is
“1”. (Note 3)
Check the bit value of bit 3 is
“0”. (Note 3)
7
6
02
Check the data is “00”.
(Note 4)
8
6
C9
10
9
6
CA
0C
10
6
D0
59
11
6
01
3D
Press PAUSE (Write) button.
12
6
02
Check the data changes to
“01”.
13
6
0C
Check the data is “00”.
14
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst luminance
point to the burst position of
color reproduction frame.
15
Check that the each color
luminance point is in each
color reproduction frame.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
CA
00
3
6
C9
00
4
6
D0
00
5
7
01
BD
6
7
00
01
Press PAUSE (Write) button.
7
0
01
00
8
Remove the C14 filter on the
lens.
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst position
R-Y
B-Y
R
G
B
M
G
C
Y
Y
E
Burst position
6-50
HDR-HC9/HC9E_ADJ
23. Auto White Balance Check 
RadarW
RadarW
RadarW
Subject
Clear chart (AWB adjustment frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified Value
Data of page: 6, address: 0C is “00”
Note 1:
Perform “Auto White Balance Adjustment” and “Color
Reproduction Adjustment” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB adjustment frame”.
If not, perform “14. Picture
Frame Setting (AWB
adjustment frame)”.
2
0
01
01
3
6
02
Check the data is “00”.
(Note 2)
4
6
CA
0D
5
6
C9
10
 
INDOOR/OUTDOOR white balance check
6
6
01
C1
Press PAUSE (Write) button.
7
6
02
Check the data changes to
“01”.
8
6
0C
Check the data is “00”.
9
6
01
00
Press PAUSE (Write) button.
 InOut check
10
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
11
6
C9
11
12
6
01
4B
Press PAUSE (Write) button.
13
6
02
Check the data changes to
“01”.
14
6
0C
Check the data is “00”.
15
6
01
00
Press PAUSE (Write) button.
16
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 2:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
CA
00
2
6
C9
00
3
0
01
00
6-51
HDR-HC9/HC9E_ADJ
24. Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
(1 m (PTB-450) or 40 cm (PTB-
1450)  from the front of lens)
Measurement Point
Video terminal of A/V jack (75 
terminated)
Measuring Instrument
Monitor TV (16:9)
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-20)
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM .................................................................... WIDE end
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
0
10
06
4
B
2F
Memorize data as D
2F
.
(6B)
5
B
2F
81
Press PAUSE (Write) button.
(6B)
6
B
2E
Memorize data as D
2E
.
(6B)
7
B
2E
08
Press PAUSE (Write) button.
(6B)
8
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
9
B
2F
D
2F
Press PAUSE (Write) button.
(6B)
10
B
2E
D
2E
Press PAUSE (Write) button.
(6B)
11
0
10
00
12
0
01
00
13
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
A clear chart must be shot in larger size 
than central nine grids. 
Fig.6-1-20
Page of 96
Display

Click on the first or last page to see other HDR-HC9 / HDR-HC9E (serv.man4) service manuals if exist.