DOWNLOAD Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ↓ Size: 857.39 KB | Pages: 96 in PDF or view online for FREE

Model
HDR-HC9 HDR-HC9E (serv.man4)
Pages
96
Size
857.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-44
HDR-HC9/HC9E_ADJ
17. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart (AWB adjustment frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
84 to 87, 98 to A7, F8 to FF
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB adjustment frame”.
If not, perform “14. Picture
Frame Setting (AWB
adjustment frame)”
2
Place the C14 filter on the
lens.
3
0
01
01
4
6
02
Check the data is “00”.
(Note 3)
5
6
CA
08
6
0
10
06
7
F
84
2A
Press PAUSE (Write) button.
(6F)
8
F
85
80
Press PAUSE (Write) button.
(6F)
9
F
86
5E
Press PAUSE (Write) button.
(6F)
10
F
87
40
Press PAUSE (Write) button.
(6F)
11
0
10
00
12
6
01
45
Press PAUSE (Write) button.
(Note 4)
13
6
02
Check the data changes to
“01”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
6F, address: 98 to A7, F8 to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
CA
00
3
0
01
00
4
Remove the C14 filter on the
lens.
6-45
HDR-HC9/HC9E_ADJ
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
4D
40
2
6
90
XL
3
6
91
XH
4
6
92
YL
5
6
93
YH
6
6
01
79
Press PAUSE (Write) button.
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
4D
00
2
6
01
00
Press PAUSE (Write) button.
3
6
90
00
4
6
91
00
5
6
92
00
6
6
93
00
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-13
2. Vertical period
Fig. 6-1-14
Check on the monitor TV (Underscanned mode)
Fig. 6-1-15
18. Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV (16:9)
Specified Value
A = B, C = D, E = F
Note 1:
Perform “Hall Adjustment” and “Flange Back Adjust-
ment” before this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu Setting) ......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Setting method:
Order Page Address Data
Procedure
1
6
4D
40
2
Adjust the zoom and the
camera direction, and set the
specified position.
3
Mark the position of the
picture frame on the monitor
TV, and adjust the picture
frame to this position in
following adjustment using
“Color reproduction
adjustment frame”.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
H
A = B
C = D
A B
C D
E = F = 0
V
E
F
Color bar chart picture frame
Monitor TV picture frame
A = B
E = F = 0
C = D
A
B
E
F
C
D
6-46
HDR-HC9/HC9E_ADJ
R-Y
B-Y
R
G
B
C
Y
Y
E
M
G
Burst position
19. Color Reproduction Adjustment & Check
(Indoor HD) 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video reminal of A/V jack
(75 
Ω terminated)
Measuring Instrument
Vectorscope, Oscilloscope
Adjustment Page
6F
Adjustment Address
A8 to AF, B0 to B7
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Fig. 6-1-16
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting). ......................................... MANUAL
6) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
Perform “18. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.
2
0
01
01
3
7
01
BD
4
7
00
01
Press PAUSE (Write) button.
5
6
9B
Check the bit value of bit 2, 3
is “0”. (Note 3)
6
6
02
Check the data is “00”.
(Note 4)
7
6
C9
10
8
6
CA
0C
9
6
D0
59
10
6
01
61
Press PAUSE (Write) button.
(Note 5)
11
6
02
Check the data changes to
“01”.
12
6
0C
Check the data is “00”.
13
Adjust the GAIN and
PHASE of the verctorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
14
Check the each color
luminance point is in each
color reproduction frame.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, ”4-
4.3. Bit value discrimitaion”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: A8 to B7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
CA
00
3
6
C9
00
4
6
D0
00
5
0
01
00
HDR-HC9
HDR-HC9E
R-Y
Burst position
B-Y
R
G
B
C
Y
Y
E
M
G
6-47
HDR-HC9/HC9E_ADJ
20. Color Reproduction Check (Indoor SD) 
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Measurement Point
Video terminal of
Adjusting
A/V jack
remote
(75 
 
terminated) commander
Measuring Instrument
Vectorscope
Specified Value
All color
Data of page: 6,
luminance
address: 0C is
points should
“00”.
settle within each
color
reproduction
frame.
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
HDR-HC9
HDR-HC9E
Fig. 6-1-17
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
Perform “18. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.
2
0
01
01
3
7
01
BE
4
7
00
01
Press PAUSE (Write) button.
5
6
9B
Check the bit value of bit 2 is
“1”. (Note 3)
Check the bit value of bit 3 is
“0”. (Note 3)
6
6
02
Check the data is “00”.
(Note 4)
7
6
C9
10
8
6
CA
0C
9
6
D0
59
10
6
01
4D
Press PAUSE (Write) button.
11
6
02
Check the data changes to
“01”.
12
6
0C
Check the data is “00”.
13
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst luminance
point to the burst position of
color reproduction frame.
14
Check that the each color
luminance point is in each
color reproduction frame.
Note 3:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
CA
00
3
6
C9
00
4
6
D0
00
5
7
01
BD
6
7
00
01
Press PAUSE (Write) button.
7
0
01
00
R-Y
Burst position
B-Y
R
G
B
C
Y
Y
E
M
G
R-Y
B-Y
R
G
B
C
Y
Y
E
M
G
Burst position
Page of 96
Display

Click on the first or last page to see other HDR-HC9 / HDR-HC9E (serv.man4) service manuals if exist.