6-28
HDR-HC9/HC9E_ADJ
6F Page table
Address
Initial value
Remark
NTSC PAL
8F
AC
AC
90
14
14
91
AE
AE
92
05
05
93
A6
A6
AWB standard data input
94
14
14
95
B2
B2
96
05
05
97
A5
A5
98
0C
0C
99
4E
4E
9A
09
09
9B
08
08
9C
0C
0C
9D
39
39
9E
09
09
9F
02
02
A0
0C
0C
AWB adj.
A1
34
34
A2
08
08
A3
FC
FC
A4
0C
0C
A5
2D
2D
A6
08
08
A7
F3
F3
A8
E5
E5
A9
DB
DB
AA
6E
6E
AB
58
58
AC
05
05
AD
11
11
AE
65
65
AF
6C
6C
B0
E5
E5
Color reproduction adj.
B1
DB
DB
B2
6E
6E
B3
58
58
B4
05
05
B5
11
11
B6
65
65
B7
6C
6C
B8 to C7
Fixed data-1 (Initialized data)
C8
03
03
C9
AA
AA
CA
FF
FF
Linear matrix adj. (2)
CB
B5
B5
CC
00
00
Address
Initial value
Remark
NTSC PAL
CD
30
30
CE
00
00
CF
01
01
D0
03
03
D1
F0
F0
D2
00
00
D3
20
20
D4
00
00
D5
13
13
D6
FF
FF
D7
54
54
D8
04
04
D9
87
87
DA
04
04
DB
5F
5F
DC
00
00
Linear matrix adj. (2)
DD
4C
4C
DE
FF
FF
DF
D0
D0
E0
00
00
E1
00
00
E2
04
04
E3
0B
0B
E4
FF
FF
E5
E4
E4
E6
FF
FF
E7
EE
EE
E8
00
00
E9
99
99
EA
03
03
EB
85
85
EC to EF
Fixed data-1 (Initialized data)
F0
14
14
F1
AD
AD
F2
05
05
F3
A7
A7
F4
14
14
AWB standard data input
F5
95
95
F6
05
05
F7
AA
AA
F8
0C
0C
F9
37
37
FA
09
09
FB
01
01
FC
0C
0C
AWB adj.
FD
0A
0A
FE
09
09
FF
02
02
6-29
HDR-HC9/HC9E_ADJ
1-2-4.
Initialization of 7C, 7E, 7F Page Data
1.
Initializing of 7C, 7E, 7F Page Data
Note 1:
If “Initialization of Pages 7C, 7E, 7F” is executed, all
data on pages 7C, 7E, 7F are initialized.
(Only an individual page cannot be initialized)
Note 2:
If the 7C, 7E, 7F page data has been initialized, the fol-
lowing adjustments need to be performed again.
1) Modification of 7C, 7E, 7F page data
2) HALL adjustment (1) (if all areas were initialized)
3) Angular velocity sensor sensitivity adjustment (if all
areas were initialized)
Adjustment Page
7C
Adjustment Address
00 to FF
Adjustment Page
7E
Adjustment Address
00 to FF
Adjustment Page
7F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
07
3
2
01
2D
Press PAUSE (Write) button.
(72)
4
2
02
Check the data changes to
(72)
“01”.
5
2
01
00
Press PAUSE (Write) button.
(72)
6
0
10
00
7
Perform “Modification of
7C, 7E, 7F Page Data”.
2.
Modification of 7C, 7E, 7F Page Data
If the 7C, 7E, 7F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Processing before Modification 7C, 7E, 7F
page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
71
01
Press PAUSE (Write) button.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 7C, 7E, 7F, set data: 01 to
page: 0, address: 10, and then select pages C, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
Processing after Completing Modification 7C, 7E, 7F
page data:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
70
10
Press PAUSE (Write) button.
4
3
70
Check the data changes to
“11”.
5
2
00
29
6
2
01
29
Press PAUSE (Write) button.
6-30
HDR-HC9/HC9E_ADJ
3.
7C Page table
Note 1:
If reading/writing data on pages 7C, set data: 07 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 7C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
13
14
Fixed data-2
15
16, 17
Fixed data-1 (Initialized data)
18
19
Fixed data-2
1A to FF
Fixed data-1 (Initialized data)
4.
7E Page table
Note 1:
If reading/writing data on pages 7E, set data: 07 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 7E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 16
Fixed data-1 (Initialized data)
17
Fixed data-2
18 to 50
Fixed data-1 (Initialized data)
51
Fixed data-2
52
Fixed data-1 (Initialized data)
53
Fixed data-2
54 to AA
Fixed data-1 (Initialized data)
AB
Fixed data-2
AC, AD
Fixed data-1 (Initialized data)
AE
Fixed data-2
AF to C3
Fixed data-1 (Initialized data)
C4
C5
Fixed data-2
C6 to EF
Fixed data-1 (Initialized data)
F0
Fixed data-2
F1 to FF
Fixed data-1 (Initialized data)
6-31
HDR-HC9/HC9E_ADJ
5.
7F Page table
Note 1:
If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of 7C, 7E, 7F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 7C, 7E, 7F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 03
Fixed data-1 (Initialized data)
04
80
80
05
80
80
06
80
80
07
80
80
08
03
03
09
77
77
0A
03
03
HALL adj. (1)
0B
79
79
0C
00
00
0D
A3
A3
0E
00
00
0F
83
83
10, 11
Fixed data-1 (Initialized data)
12
36
36
Angular velocity sensor sensitive
13
36
36
adj.
14 to FF
Fixed data-1 (Initialized data)