DOWNLOAD Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ↓ Size: 857.39 KB | Pages: 96 in PDF or view online for FREE

Model
HDR-HC9 HDR-HC9E (serv.man4)
Pages
96
Size
857.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-16
HDR-HC9/HC9E_ADJ
3.
F Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 3E
Fixed data-1 (Initialized data)
3F
Fixed data-2
40
Fixed data-1 (Initialized data)
41
Fixed data-2
42 to FF
Fixed data-1 (Initialized data)
4.
63 Page table
Note 1:
If reading/writing data on pages 63, set data: 06 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 63 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 91
Fixed data-1 (Initialized data)
92
Fixed data-2
93 to CA
Fixed data-1 (Initialized data)
CB
CC
Fixed data-2
CD to D3
Fixed data-1 (Initialized data)
D4
D5
Fixed data-2
D6
D7
Fixed data-1 (Initialized data)
D8
D9
Fixed data-2
DA to E2
Fixed data-1 (Initialized data)
E3
E4
E5
Fixed data-2
E6
E7
Fixed data-1 (Initialized data)
E8
E9
EA
Fixed data-2
EB
EC to FF
Fixed data-1 (Initialized data)
6-17
HDR-HC9/HC9E_ADJ
Address
Initial value
Remark
NTSC PAL
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
Fixed data-2
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
Fixed data-1 (Initialized data)
6B
6C
6D
Fixed data-2
6E
6F
70
Fixed data-1 (Initialized data)
71
72
73
74
Fixed data-2
75
76
77
78
Fixed data-1 (Initialized data)
79
7A
7B
Fixed data-2
7C
7D
5.
64 Page table
Note 1:
If reading/writing data on pages 64, set data: 06 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 64 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 0F
Fixed data-1 (Initialized data)
10
11
Fixed data-2
12 to 1F
Fixed data-1 (Initialized data)
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
Fixed data-2
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40 to 49
Fixed data-1 (Initialized data)
4A
4B
4C
Fixed data-2
4D
6-18
HDR-HC9/HC9E_ADJ
64 Page table
Address
Initial value
Remark
NTSC PAL
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
Fixed data-2
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
Fixed data-1 (Initialized data)
9B
9C
9D
Fixed data-2
9E
9F
A0
Fixed data-1 (Initialized data)
A1
A2
A3
A4
Fixed data-2
A5
A6
A7
A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA
Fixed data-1 (Initialized data)
AB
Fixed data-2
AC to AF
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
B0
B1
B2
Fixed data-2
B3
B4 to D7
Fixed data-1 (Initialized data)
D8
D9
Fixed data-2
DA
Fixed data-1 (Initialized data)
DB
DC
Fixed data-2
DD
DE
Fixed data-1 (Initialized data)
DF
Fixed data-2
E0, E1
Fixed data-1 (Initialized data)
E2
Fixed data-2
E3 to EC
Fixed data-1 (Initialized data)
ED
Fixed data-2
EE, EF
Fixed data-1 (Initialized data)
F0
F1
Fixed data-2
F2
Fixed data-1 (Initialized data)
F3
Fixed data-2
F4 to FE
Fixed data-1 (Initialized data)
FF
Fixed data-2
6-19
HDR-HC9/HC9E_ADJ
6.
65 Page table
Note 1:
If reading/writing data on pages 65, set data: 06 to page:
0, address: 10, and then select pages: 5. By this data set-
ting, the pages 65 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 10
Fixed data-1 (Initialized data)
11
Fixed data-2
12
Fixed data-1 (Initialized data)
13
Fixed data-2
14
Fixed data-1 (Initialized data)
15
16
17
18
Fixed data-2
19
1A
1B
1C to 1E
Fixed data-1 (Initialized data)
1F
Fixed data-2
20 to 2D
Fixed data-1 (Initialized data)
2E
Fixed data-2
2F
Fixed data-1 (Initialized data)
30
31
Fixed data-2
32 to 35
Fixed data-1 (Initialized data)
36
Fixed data-2
37
Fixed data-1 (Initialized data)
38
Fixed data-2
39 to FF
Fixed data-1 (Initialized data)
7.
66 Page table
Note 1:
If reading/writing data on pages 66, set data: 06 to page:
0, address: 10, and then select pages: 6. By this data set-
ting, the pages 66 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of F, 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of F, 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
13
Fixed data-2
14 to 97
Fixed data-1 (Initialized data)
98
Fixed data-2
99
Fixed data-1 (Initialized data)
9A
9B
Fixed data-2
9C, 9D
Fixed data-1 (Initialized data)
9E
9F
Fixed data-2
A0 to A6
Fixed data-1 (Initialized data)
A7
Fixed data-2
A8 to AE
Fixed data-1 (Initialized data)
AF
Fixed data-2
B0 to C1
Fixed data-1 (Initialized data)
C2
C3
Fixed data-2
C4
C5 to C7
Fixed data-1 (Initialized data)
C8
Fixed data-2
C9 to DF
Fixed data-1 (Initialized data)
E0
E1
E2
Fixed data-2
E3
E4 to E6
Fixed data-1 (Initialized data)
E7
E8
E9
Fixed data-2
EA
EB
EC to EE
Fixed data-1 (Initialized data)
EF
F0
F1
Fixed data-2
F2
F3
F4 to F6
Fixed data-1 (Initialized data)
Page of 96
Display