DOWNLOAD Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ↓ Size: 857.39 KB | Pages: 96 in PDF or view online for FREE

Model
HDR-HC9 HDR-HC9E (serv.man4)
Pages
96
Size
857.39 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-36
HDR-HC9/HC9E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
06
1C
33
Set the following data
4
06
1D
11: HDR-HC9
12: HDR-HC9E
Set the following data
5
06
1E
BC: HDR-HC9
00: HDR-HC9E
6
6
02
Check the data is “00”.
(Note 6)
7
6
4D
40
8
6
64
04
9
6
01
13
Press PAUSE (Write) button.
10
Wait for 2 seconds.
11
6
01
15
Press PAUSE (Write) button.
(Note 7)
12
Wait for 10 seconds.
13
6
02
Check the data changes to
“01”.
14
6
0C
Check the data is “00”.
15
0
10
06
16
F
2F
Check the data is “00” to
(6F)
“09”.
17
0
10
00
Note 6:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 7:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
2
6
64
00
3
6
4D
00
4
6
1E
00
5
6
1D
00
6
6
1C
00
7
0
01
00
Perform “Flange Back
8
Check ”.
6.
Flange Back and Zoom Key Adjustment (1)
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
6-1. Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(
Illuminance
: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 20 to 3F
Specified value
Data of page: 6F, address: 2F is
“00” to “09”
Data of pege: 6, address: 0C is “00”
Note 1:
Perform “HALL Adjustment”, “HALL/MR Adjustment”
and “Differential Gain Adjustment” before this adjust-
ment.
Note 2:
Perform the adjustment with the lens in horizontal state.
Note 3:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4:
Don’t touch the zoom lever during adjustment.
Note 5:
After adjustment, if the focusing to a subject located at
infinity failed, increase the illuminance of the chart and
perform readjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.05
6-37
HDR-HC9/HC9E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
06
1C
33
Set the following data
4
06
1D
11: HDR-HC9
12: HDR-HC9E
Set the following data
5
06
1E
BC: HDR-HC9
00: HDR-HC9E
6
6
02
Check the data is “00”.
(Note 4)
7
6
4D
40
8
6
64
04
9
6
01
13
Press PAUSE (Write) button.
10
Wait for 2 seconds.
11
6
01
29
Press PAUSE (Write) button.
(Note 5)
12
Wait for 10 seconds.
13
6
02
Check the data changes to
“01”.
14
6
0C
Check the data is “00”.
15
0
10
06
16
F
2F
Check the data is “00” to
(6F)
“09”.
17
0
10
00
Note 4:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5:
The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
2
6
64
00
3
6
4D
00
4
6
1E
00
5
6
1D
00
6
6
1C
00
7
0
01
00
Perform “Flange Back
8
Check ”.
6-2. Flange Back and Zoom Key Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
6F
Adjustment Address
11, 20 to 3F
Specified value
Data of page: 6F, address: 2F is“00” to “09”
Data of page: 6, address: 0C is“00”
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
4) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
RadarW
RadarW
RadarW
6-38
HDR-HC9/HC9E_ADJ
7.
Flange Back Check
(Using the flange back adjustment jig)
Subject
Flange back adjustment jig
(
Illuminance
: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) To open the IRIS, decrease the luminous intensity to the chart
of the flange back adjustment jig up to a point before noise
appear on the image. (approx. 200 lux)
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the chart with the
zoom TELE end.
5
6
2C
02
6
Check that the lens is
focused.
7
Shoot the chart with the
zoom WIDE end.
8
Check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
6
40
00
3
6
41
00
4
6
4D
00
8.
Flange Back Check (Using the Siemens star)
Subject
Siemens star
(2.0 m from the front of the lens)
(
Illuminance
: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Preparations before adjustments:
1) Place the Siemens star 2.0 m from the front of the lens.
2) To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
Checking method:
Order Page Address Data
Procedure
1
6
40
01
2
6
41
01
3
6
4D
40
4
Shoot the Siemens star with
the zoom TELE end.
5
Turn on the auto focus.
6
0
03
0F
7
1
Check that the lens is
focused. (Note 2)
8
6
21
10
9
Shoot the Siemens star with
the zoom WIDE end.
10
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
6
4D
40
5
0
03
00
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2008.05
6-39
HDR-HC9/HC9E_ADJ
10. Mechanical Shutter Adjustment (1) 
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Adjustment Page
69
Adjustment Address
A0 to B5
Note 1:
 If reading/writing data on pages 69 set data: 06 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 0, address: 10, and set data: 06.
3) Input the following data to page: 9 (69), address: A0 to B5.
Note 2:
Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address
Data
NTSC PAL
A0
0F
0C
A1
80
B0
A2
0B
09
A3
00
10
A4
08
07
A5
C0
20
A6
07
05
A7
00
A0
A8
05
04
A9
40
70
AA
54
55
AB
65
65
AC
63
64
AD
5C
5C
AE
4B
4B
AF
21
22
B0
80
80
B1
80
80
B2
80
80
B3
80
80
B4
80
80
B5
80
80
4) Select page: 0, address: 10, and set data: 00.
5) Select page: 0, address: 01, and set data: 00.
9.
F No. & ND Light Quality Standard Data Input
Correct the lens iris and dispersion of the ND filter light quantity.
Subject
Clear chart (Center frame)
(40 cm (PTB-1450) from the front of
lens)
Adjustment Page
69
Adjustment Address
E0 to EF
Note 1:
If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 2)
3
6
01
BB
Press PAUSE (Write) button.
4
6
02
Check the data changes to
“01”.
5
6
0C
Check the data is “00”.
Note 2:
If not, select page: 6, address: 02, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
RadarW
RadarW
RadarW
RadarW
RadarW
Page of 96
Display

Click on the first or last page to see other HDR-HC9 / HDR-HC9E (serv.man4) service manuals if exist.