6-52
HDR-HC9/HC9E_ADJ
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
C9
00
2
6
40
00
3
6
2C
00
4
6
4D
00
5
6
01
00
Press PAUSE (Write) button.
6
0
01
00
25. MAX GAIN Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Clear chart (Center frame)
Adjustment Page
69
Adjustment Address
DE
Note 1:
Perform “Flange Back Adjustment” before this adjust-
ment.
Note 2:
If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHT SHOT .................................................................. OFF
3) ZOOM .................................................................... WIDE end
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
7) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Center Frame”. If not,
perform “24. Picture Frame
Setting (Center Frame)”
2
0
01
01
3
0
10
06
4
9
DE
FF
Press PAUSE (Write) button.
(69)
5
0
10
00
6
6
02
Check the data is “00”.
(Note 3)
7
6
4D
40
8
6
2C
01
9
6
C9
10
10
6
D0
Set the following data
28: HDR-HC9
22: HDR-HC9E
11
6
D1
Set the following data
80: HDR-HC9
80: HDR-HC9E
12
6
01
6F
Press PAUSE (Write) button.
(Note 4)
13
6
02
Check the data changes to
“01”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
The adjustment data will be automatically input to page:
69, address: DE.
6-53
HDR-HC9/HC9E_ADJ
26. HS White Defect Adjustment 
RadarW
RadarW
RadarW
Defect white defective pixels of CMOS image sensor. (HS mode)
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Note 1:
Perform “MAX GAIN Adjustment” before this adjust-
ment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Preparation for adjustment:
1) Before starting this adjustment, make sure that the lens ther-
mistor data of the set exceeds 39 degrees. If not, perform the
aging by the following method (aging temperature judge mode)
until the temperature exceeds 39 degrees.
Aging temperature judge mode:
Order Page Address Data
Procedure
1
Reverse and close the panel
of the set.
2
0
01
01
3
0
10
06
4
B
7C
27
Press PAUSE (Write) button.
(6B)
5
During the aging, the screen
will be as follows.
(Fig. 6-1-21)
When the temperature is
below 39 ºC, “grid” screen
appears. When the aging
continues and the tempera-
ture exceeds 39 ºC, “ color
bar” screen appears.
6
When the aging completed,
execute the subsequent steps
to exit the aging temperature
judge mode.
7
B
7C
00
Press PAUSE (Write) button.
(6B)
8
0
10
00
9
0
01
00
Fig.6-1-21
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
D0
88
3
6
01
21
Press PAUSE (Write) button.
4
6
02
Check the data changes to
“01”.
5
6
01
00
Press PAUSE (Write) button.
6
6
02
Check the data is ”00”.
(Note 3)
7
6
E0
Check the data is “27” to
“FF”. (Note 4)
8
6
07
Check the data is “04”.
9
0
10
06
10
2
BA
3F
Press PAUSE (Write) button.
(62)
11
2
BB
30
Press PAUSE (Write) button.
(62)
12
0
10
00
13
6
0E
81
14
Wait for 1 second.
15
6
D0
44
16
6
01
21
Press PAUSE (Write) button.
17
6
02
Check the data changes to
“01”.
Note 3:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4:
If the data is other than “27” to “FF”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
0E
00
3
Wait for 1 second.
4
0
10
06
5
2
BA
20
Press PAUSE (Write) button.
(62)
6
2
BB
20
Press PAUSE (Write) button.
(62)
7
0
10
00
8
0
01
00
Aging completed
(Exceeding the set 
temperature)
During aging
(Below the set temperature)
6-54
HDR-HC9/HC9E_ADJ
27. White Defect Adjustment 
RadarW
RadarW
RadarW
Defect white defective pixels of CMOS image sensor.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6 address: D3 is “00”
or “02” to “FF”.
Note 1:
Perform “HS White Defect Adjustment” before this ad-
justment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 39 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 39 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “27” to
“50”.
4
6
07
Check the data is “04”.
5
6
D0
06
6
6
01
21
Press PAUSE (Write) button.
7
Wait for 10 seconds.
8
6
02
Check the data changes to
“01”.
9
6
D3
Check the data is “00” or
“02” to “FF”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
28. White Defect Adjustment (FD white point)
RadarW
RadarW
RadarW
Defect white defective pixels (FD white point) of CMOS image
sensor.
Subject
Not required
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 39 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 39 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “27” to
“50”. (Note 6)
4
6
07
Check the data is “04”.
5
6
D0
0C
6
6
01
21
Press PAUSE (Write) button.
7
6
02
Check the data changes to
“01”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
If the data is other than “27” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-55
HDR-HC9/HC9E_ADJ
29. White Defect Check 
RadarW
RadarW
RadarW
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Specified value
Data of page: 6, address: D2 is “00”
to “08”
Note 1:
Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 39 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 39 degrees.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
02
Check the data is “00”.
(Note 5)
3
6
E0
Check the data is “27” to
“50”. (Note 6)
4
6
07
Check the data is “04”.
5
6
D0
04
6
6
01
21
Press PAUSE (Write) button.
7
6
02
Check the data changes to
“01”.
8
6
D1
Check the data is “00”.
9
6
D2
Check the data is “00” to
“08”.
Note 5:
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6:
If the data is other than “27” to “50”, perform the aging.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
30. Black Defect Adjustment 
RadarW
RadarW
RadarW
Defect black defective pixels of CMOS image sensor.
Subject
Clear chart (All white) (Note 1)
Note 1:
 Perform “White Defect Adjustment” before this adjust-
ment.
Note 2:
Perform adjustments successively, starting from the “HS
White Defect Adjustment”.
Note 3:
The lens thermistor data of the set must exceed 39 de-
grees.
If not, perform the aging in the aging temperature judge
mode until the set exceeds 39 degrees.
Note 4:
Shoot the clear chart with the zoom TELE end.
Note 5:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
Turn off the power and turn
on again.
2
0
01
01
3
6
02
Check the data is “00”.
(Note 6)
4
6
07
Check the data is “04”
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
10
10
6
01
79
Press PAUSE (Write) button.
11
Wait for 1.5 seconds.
12
Check that the entire screen
is white.
13
6
D0
01
14
6
01
21
Press PAUSE (Write) button.
15
6
02
Check the data changes to
“01”.
Note 6:
 If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
01
79
Press PAUSE (Write) button.
7
Wait for 1.5 seconds.
8
6
01
00
Press PAUSE (Write) button.
9
6
2C
00
10
0
01
00
Page of 96