Movie / SECTION 6 ADJUSTMENTS
File
hdr-hc9-hdr-hc9e-sm4.pdf
Date

Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual ▷ View online

6-64
HDR-HC9/HC9E_ADJ
6-2. MECHANISM  SECTION  ADJUSTMENTS
On the mechanism section adjustment
For details of mechanism section adjustments, checks, and replace-
ment of mechanism parts, refer to the separate volume “DV ME-
CHANICAL ADJUSTMENT MANUAL IX  N Mechanism  ”.
Note:
Before performing the adjustments, check the data of page:
0, address: 10 is “00”. If not, set data: 00 to this address.
2-1.
HOW  TO  ENTER  RECORD  MODE
WITHOUT  CASSETTE
1) Connect the adjustment remote commander to the LANC jack.
2) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, set data: 0C, and press the PAUSE
(Write) button of the adjustment remote commander.
(The mechanism enters the record mode automatically.)
Note:
The function buttons become inoperable.
5) To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE (Write) button of the adjustment re-
mote commander.  (Whenever you want to quit the record
mode, be sure to quit following this procedure.)
2-2.
HOW  TO  ENTER  PLAYBACK  MODE
WITHOUT  CASSETTE
1) Connect the adjustment remote commander to the LANC jack.
2) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
3) Close the cassette compartment without the cassette.
4) Select page: 3, address: 01, set data: 0B, and press the PAUSE
(Write) button of the adjustment remote commander.
(The mechanism enters the playback mode automatically.)
Note:
The function buttons become inoperable.
5) To quit the playback mode, select page: 3, address: 01, set
data: 00, and press the PAUSE (Write) button of the adjust-
ment remote commander.  (Whenever you want to quit the play-
back mode, be sure to quit following this procedure.)
2-3.
TAPE  PATH  ADJUSTMENT
1.
Preparation for Adjustment
1) Clean the tape running side (tape guide, drum, capstan shaft,
pinch roller, etc.).
2) Connect the adjustment remote commander to the LANC jack.
3) Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
4) Connect an oscilloscope to US-013 board CN8103 via the CPC
Connecting jigs. (J-6082-521-A, J-6082-564-A)
Channel 1: US-013 board, CN8103 Pin 1 (Note)
External trigger: US-013 board, CN8103 Pin 2
Note:
Connect a 75 
Ω resistor between pins 1 of CN8103
and 3 (GND).
75 
Ω resistor (Parts code: 1-247-804-11)
5) Playback the alignment tape for tracking. (XH2-1)
6) Select page: 3, address: 33, and set data: 08.
7) Select page: 3, address: 26, set data: 31, and press the PAUSE
(Write) button.
8) Check that the oscilloscope RF waveform is normal at the en-
trance and exit.
If not normal, adjust according to the separate volume
“DV MECHANICAL ADJUSTMENT MANUAL IX
 N Mechanism ”.
CN8103 of US-013 board
Pin No. Signal Name
1
RF MON
2
SWP
3
GND
4
N. C.
5
N. C.
6
N. C.
7
N. C.
8
GND
2.
Procedure after operations
1) Connect the adjustment remote commander to the LANC jack.
Set the HOLD switch to ON. (Set the slide switch to SER-
VICE).
2) Select page: 3, address: 26, set data: 00, and press the PAUSE
(Write) button.
3) Select page: 3, address: 33, and set data: 00.
Fig. 6-2-1
CH1
Entrance side
Exit side
Check this section
(Normal waveform)
CH2
(Trigger)
3.3msec
6-65
HDR-HC9/HC9E_ADJ
3-1-2.
Adjusting Connectors
The measuring point of the playback RF signal is CN8103 of US-
013 board. Connect the measuring instruments via the CPC con-
necting jigs (J-6082-521-A, J-6082-564-A). Refer to “MECHA-
NISM SECTION ADJUSTMENT” for the measuring method. The
following table lists the pin numbers and signal names of CN8103.
Pin No. Signal Name
1
RF_MON
2
SWP
3
GND
4
N. C.
5
N. C.
6
N. C.
7
N. C.
8
GND
Table 6-3-1
3-1-3.
Connecting the Equipment
Connect the measuring instruments as shown in Fig. 6-3-1, and
perform the adjustments.
Fig. 6-3-1
6-3. VIDEO  SECTION  ADJUSTMENTS
3-1.
PREPARATIONS  BEFORE  ADJUSTMENTS
Use the following measuring instruments for video section adjust-
ments.
3-1-1.
Precautions on Adjusting
Note:
Before performing the adjustment, check the data of page:
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”.
1) The adjustments of this unit are performed in the VTR mode
(PLAY/EDIT mode) or camera mode (CAMERA-TAPE
mode).
US-013 board
CN8103
Adjustment remote commander
RM-95
(J-6082-053-B)
NEW LANC JIG
(J-6082-565-A)
LANC cable
(J-6082-442-A)
AC IN
AC adaptor
AC-L200/L200B
(1-479-285-21)
For tape path adjustment
8
8
1
1
 RF MON
 SWP
 GND
CPC-15
(J-6082-564-A)
CN002
CN001
BATT
LANC
Not used
Not used
Not used
*1
*1
I/F unit for LANC control
(J-6082-521-A)
*1: Don't connect any cable
      to these connectors.
1
3
2
1
3
2
3
LANC jack
CPC lid
A/V OUT jack
COMPONENT OUT jack
Osilloscope
Terminated
75 
Osilloscope
Terminated
75 
Audio L (White)
Audio R (Red)
Video
 (Yellow)
S Video
 (Black)
Pr (Red)
Pb (Blue)
Y (Green)
VIDEO system adjustment (COMPONENT OUT)
VIDEO system adjustment (S VIDEO, VIDEO)
DC IN jack
6-66
HDR-HC9/HC9E_ADJ
3-1-4.
Alignment Tapes
Use the alignment tapes shown in the following table.
Use tapes specified in the signal column of each adjustment.
Name
Use
Tracking standard (XH2-1)
Tape path adjustment
SW/OL standard (XH2-3)
Switching position adjust-
ment
Audio operation check
Audio system adjustment
(XH5-3 (NTSC), XH5-3P (PAL))
System operation check
Operation check
(XH5-5 (NTSC), XH5-5P (PAL))
Fig. 6-3-2 shows the 75% color bar signals recorded on the align-
ment tape for Audio Operation Check.
Note:
 Measure with video terminal (Terminated at 75 
Ω)
Fig. 6-3-2 Color bar signal of alignment tapes
For NTSC model
For PAL model
Color bar signal waveform
Color bar pattern
Color bar signal waveform
Color bar pattern
3-1-5.
Output Level and Impedance
1 V
0.714 V
0.286 V
White (75%)
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
0.286 V
Q
I
Horizontal sync signal
(75%)
White
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Q
I
White
(100%)
Black
1 V
0.7 V
0.3 V
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3 V
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
Audio/Video output
10-pin connector
Video signal: 1 Vp-p, 75 
Ω (ohms), unbalanced
Luminance si gnal : 1 Vp-p, 75
Ω (ohms), unbalanced
Chrominance signal: 0.286 Vp-p, 75 
Ω (ohms), unbalanced (NTSC)
Chrominance signal: 0.3 Vp-p, 75 
Ω (ohms), unbalanced (PAL)
Audio si gna l: 327  mV (at load  impedance 47 k
Ω (kilohms)), 
Output  impedance with less than 2.2 k
Ω (kilohms)
COMPONENT OUT jack
Y: 1 Vp-p, 75
Ω (ohms), unbalanced P
B
/ P
R
, C
B
/C
R
: +/- 350 mVp-p
6-67
HDR-HC9/HC9E_ADJ
D
1
 (decimal)
D
2
 (decimal)
H
1
 (hexadecimal)
(Service model code)
00001 to 65535
D
1
FE
65536 to 131071
D
1
 
− 65536
FE
131072 to196607
D
1
 
− 131072
FE
196608 to 262143
D
1
 
− 196608
FE
262144 to 327679
D
1
 
− 262144
FE
327680 to 393215
D
1
 
− 327680
FE
393216 to 458751
D
1
 
− 393216
FE
458752 to 524287
D
1
 
− 458752
FE
524288 to 589823
D
1
 
− 524288
FE
589824 to 655359
D
1
 
− 589824
FE
655360 to 720895
D
1
 
− 655360
FE
720896 to 786431
D
1
 
− 720896
FE
786432 to 851967
D
1
 
− 786432
FE
851968 to 917503
D
1
 
− 851968
FE
917504 to 983039
D
1
 
− 917504
FE
983040 to 999999
D
1
 
− 983040
FE
Table 6-3-2
5) Enter H
1
 to address: 09 on page: 13.
Example: If H
1
 = FE,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 09, and set data: FE, then press
the PAUSE (Write) button.
6) From Table 6-3-3, obtain the maximum decimal number less
than D
2
, and it is assumed to be D
3
.
Example: If D
2
 = 12345.
D
3
 = 12288
7) From Table 6-3-3, obtain a hexadecimal number that corre-
sponds to D
3
, and it is assumed to be H
3
.
Example: If D
3
 = 12288,
H
3
 = 3000
8) C a l u c u l a t e   D
4
  u s i n g   fo l l ow i n g   e q u a t i o n s   ( d e c i m a l
caluculation). (0   D
4
 
 225)
D
4
 = D
2
 – D
3
Example: If D
2
 = 12345 and D
3
 = 12288,
D
4
 = 12345 – 12288 = 57
9) Convert D
4
 into a hexadecimal number to obtain H
4
. (See Table
6-4-1 “Hexadecimal - decimal conversion table” in 6-4. Ser-
vice Mode)
Example: If D
4
 = 57,
H
4
 = 39
10) Enter higher two digits of H
3
 to address: 0A on page: 13.
Example: If H
3
 = 3000,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0A, and set data: 30, then press
the PAUSE (Write) button.
11) Enter H
4
 to address: 0B on page: 13.
Example: If H
4
 = 39,
Select page: 0, address: 10, and set data: 01.
Select page: 3 (13), address: 0B, and set data: 39, then press
the PAUSE (Write) button.
12) Select page: 0, address: 10, and set data: 00.
13) Select page: 3, address: 70, and set data: 10, then press the
PAUSE (Write) button.
14) Select page: 3, address: 70, and check that the data changes to
“11”.
15) Select page: 0, address: 01, and set data: 00.
3-2.
SYSTEM  CONTROL  SYSTEM  ADJUSTMENTS
1.
Initialization of EEPROM Data
If the EEPROM data is erased due to some reason, perform “1-2.
INITIALIZATION OF EEPROM DATA”, of “6-1. CAMERA
SECTION ADJUSTMENTS”
2.
Node Unique ID No. Input
Note 1:
Perform “2-2. Input of Serial No.” if the data on page 13
has been cleared and original node unique ID No. is un-
certain.
Usually, read the data on page 13 before repair, and write
it after repair.
Note 2:
If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
2-1. Input of Company ID
Write the company ID to the EEPROM (nonvolatile memory).
Page
13
Address
04, 05, 06, 07, 08
Input method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 71, and set data: 01, then press the
PAUSE (Write) button.
3) Select page: 0, address: 10, and set data: 01.
4) Select page: 3 (13), and enter the following data.
Note 3:
Each time the data is set, press the PAUSE (Write) but-
ton on the adjusting remote commander.
Address
Data
04
08
05
00
06
46
07
01
08
02
5) Select page: 0, address: 10, and set data: 00.
6) Select page: 3, address: 70, and set data: 10, then press the
PAUSE (Write) button.
7) Select page: 3, address: 70, and check that the data changes to
“11”.
8) Select page: 0, address: 01, and set data: 00.
2-2. Input of Serial No.
Write the serial No. and model code to the EEPROM (nonvolatile
memory).
In writing the serial No., a decimal number should be converted
into a hexadecimal number
Page
13
Address
 09, 0A, 0B
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 71, and set data: 01, then press the
PAUSE (Write) button.
3) Read the serial No. from the model name label, and it is as-
sumed to be D
1
.
Example: If serial No. is “77881”,
D
1
 = 77881
4) From Table 6-3-2, obtain D
2
 and H
1
 that correspond to D
1
.
Example: If D
1
 = 77881,
D
2
 = D
1
 – 65536 = 12345
H
1
 = FE
Page of 96