DOWNLOAD Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ↓ Size: 1.47 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-PC330 DCR-PC330E (serv.man4)
Pages
74
Size
1.47 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc330-dcr-pc330e-sm4.pdf
Date

Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ▷ View online

6-10
DCR-PC330/PC330E
3. A Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 6-1-2.
4. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 17
18
19 to 2E
2F
30
31
32 to 41
42
43 to 8F
90
91
92
93
94 to FF
D2
1B
C7
10
D4
15
C4
1F
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.
Fixed data-1
Table. 6-1-3.
00 to 0F
10
11
12
13 to 15
16
17 to 19
1A
1B
1C
1D
1E
1F to 21
22
23
24
25
26
27
28
29
2A
2B
2E
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Address
Remark
Initial value
2F
30
31 to 35
36
37
38
39
3A
3B to 3C
3D
3E to 42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F to 50
51
52
53
54
55
56
57
58
59 to 6E
6F
70 to 7F
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
6-11
DCR-PC330/PC330E
1-2-2.
INITIALIZATION OF B, 1B PAGE DATA
Note: When reading or writing the B page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the B, 1B Page Data
Note1: If “Initializing the B, 1B Page Data” is performed, all data of the
B page and 1B page will be initialized. (It is impossible to initialize
a single page.)
Note2: If the B, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B, 1B page data
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
02
FF
Set the data, and press PAUSE button.
4
5
01
F3
Set the data, and press PAUSE button.
5
5
00
01
Set the data, and press PAUSE button.
6
5
02
Check that the data changes to
“00”.
7
Perform “Modification of B, 1B
Page Data”.
2. Modification of B, 1B Page Data
If the B, 1B page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set data: 01.
2)
When changing the B page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1B page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1B page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B, 1B Page data:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE button.
3. Loader Writing Inhibit Mode Setting
Setting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
5
F1
When the data is “20”, the loader
writing inhibit mode has already
been set up. So proceed to step 9.
4
5
0E
00
Set the data, and press PAUSE button.
5
5
03
20
Set the data, and press PAUSE button.
6
5
01
FA
Set the data, and press PAUSE button.
7
5
00
01
Set the data, and press PAUSE button.
8
5
0E
Check that the data is “01”.
9
0
01
01
Set the data
10
Turn off the power and turn on
again
11
5
F1
Check that the data is “20”.
4. Initializing the Personal Menu
Note: Initialize the personal menu, when A page data are initialized.
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
00
34
Set the data, and press PAUSE button.
4
7
01
34
Set the data, and press PAUSE button.
5
7
02
Check that the data is “01”.
6
0
01
00
Set the data.
5. B Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Table. 6-1-4.
6. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the B, 1B
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B, 1B
Page Data”).
Address
Remark
00 to 02
03
04 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
00 to FF Fixed data-1
Table. 6-1-5.
6-12
DCR-PC330/PC330E
1-2-3.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-13
DCR-PC330/PC330E
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Address
Remark
00 to 18
19
1A to 29
2A
2B to 3A
3B
3C to 3F
40
41 to 79
7A
7B to 83
84
85
86
87
88
89
8A
8B
8C to 91
92
93 to 94
95
96 to AB
AC
AD
AE to B0
B1
B2
B3
B4 to B5
B6
B7
B8
B9
BA
BB
BC to C3
C4
C5
C6
C7
C8
C9
CA
CB to D5
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E2
E3
E4
E5 to E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F9
FA
FB
FC to FF
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-6.
Page of 74
Display

Click on the first or last page to see other DCR-PC330 / DCR-PC330E (serv.man4) service manuals if exist.