DOWNLOAD Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ↓ Size: 1.47 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-PC330 DCR-PC330E (serv.man4)
Pages
74
Size
1.47 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc330-dcr-pc330e-sm4.pdf
Date

Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ▷ View online

6-14
DCR-PC330/PC330E
4. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6 to DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to E9
EA
EB to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Fixed data-2
Fixed data-1
Emergency memory address
(Mechanism section)
Address
Remark
Initial value
Table. 6-1-7.
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 3E
3F
40
41
42
43 to 44
45
46
47
48 to 4F
50
51
52
53
54 to 55
56
57
58
59 to 5A
5B
5C to 65
66
67 to 6A
6B
6C to 6E
6F
70 to 78
79
7A
7B
7C
7D to A3
A4
A5 to CB
EE
00
00
00
E0
5D
7D
59
80
80
94
8B
90
7C
28
6A
84
9A
88
88
71
44
A0
8C
5E
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
VCO adj. (EVF)
COM DC adj.(EVF)
RGB AMP adj. (EVF)
Fixed data-1
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-1
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-1
Transmissive mode white balance
adj. (LCD)
Contrast adj. (LCD)
Fixed data-2
PSIG black adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
6-15
DCR-PC330/PC330E
5. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
6. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modfied data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-9.
Address
Remark
00
01
02 to C2
C3
C4 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00 to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to FF
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Error rate check
Fixed data-1
Address
Remark
Initial value
Table. 6-1-8.
6-16
DCR-PC330/PC330E
1-2-4.
INITIALIZATION OF E, F, 14, 19, 1E, 1F PAGE DATA
Note: When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 14, 19, 1E, 1F page data, select page:
0, address: 10, and set data: 01, then select 4, 9, E or F page. The 14,
19, 1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 14, 19, 1E, 1F Page Data
Note1: If “Initializing the E, F, 14, 19, 1E, 1F Page Data” is performed,
all data of the E page, F page, 14 page, 19 page, 1E page and 1F
page will be initialized. (It is impossible to initialize a single page.)
Note2: If the E, F, 14, 19, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustments
Note3: NTSC model: DCR-PC330
PAL model: DCR- PC330E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
14
Adjusting Address
00 to FF
Adjusting page
19
Adjusting Address
00 to FF
Adjusting page
1E
Adjusting Address
00 to FF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
03
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
6
01
00
Set the data, and press PAUSE
button.
7
Perform “Modification of E, F,
14, 19, 1E, 1F Page Data”.
2. Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 14, 19, 1E, 1F page data, select page: 0,
address: 10, and set data: 01.
After completing the modification of  14, 19, 1E, 1F page data,
reset the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 14, 19, 1E,
1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
Perform “54MHz/67.5MHz
Origin Osc. Adjustment” of the
camera system adjustment.
6-17
DCR-PC330/PC330E
3. E Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Table. 6-1-10.
Address
Remark
00 to 02
03
04
05
06 to 07
08
09
0A
0B
0C to 0D
0E
0F
10
11
12
13 to 15
16
17
18
19
1A to 1C
1D
1E to 1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E to 2F
30
31
32 to 35
36
37
38 to 3B
3C
3D
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
3E
3F
40
41
42 to 59
5A
5B
5C
5D
5E
5F
60
61
62
63
64 to 65
66
67
68
69
6A
6B to 6E
6F
70
71 to 86
87
88 to FF
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Page of 74
Display

Click on the first or last page to see other DCR-PC330 / DCR-PC330E (serv.man4) service manuals if exist.