DOWNLOAD Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ↓ Size: 1.47 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-PC330 DCR-PC330E (serv.man4)
Pages
74
Size
1.47 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc330-dcr-pc330e-sm4.pdf
Date

Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ▷ View online

6-22
DCR-PC330/PC330E
7. 1E Page Table
Note1: When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Address
Remark
00 to 09
10
11 to 17
18
19
1A
1B
1C
1D
1E
1F
20 to 3B
3C
3D
3E
3F
40
41 to 48
49
4A
4B
4C to 51
52
53
54
55 to 69
6A
6B to 7B
7C
7B to 97
98
99
9A to 9B
9C
9D to AB
AC
AD to C3
C4
C5 to C7
C8
C9
CA
CB to CF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-14.
Address
D0
D1
D2
D3
D4
D5
D6 to D7
D8
D9
DA
DB
DC
DD to DF
E0
E1
E2
E3
E4
E5
E6 to E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1 to FF
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Remark
6-23
DCR-PC330/PC330E
8. 1F Page Table
Note1: When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Table. 6-1-15.
Address
Remark
00 to 03
04
05 to 26
27
28 to 3F
40
41
42 to 6F
70
71
72 to 95
96
95 to A2
A3
A4
A5
A6 to AB
AC
AD
AE
AF
B0 to C9
CA
CB
CC
CD
CE to E4
E5
E6 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-24
DCR-PC330/PC330E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for
“54MHz (PC330E)/67.5MHz (PC330) Origin Oscillation
Adjustment”), check that the specified values of “VIDEO
SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 54MHz (PC330E)/67.5MHz (PC330) Origin Oscillation
Adjustment (CD-452 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qk of IC1302 on VC-325 board
(R1331)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=13500000 
±
 68Hz
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
VC-325 board (SIDE A)
Fig. 6-1-8
32
33
48
49
1
16
17
64
IC1302
R1331
COVER
COVER
Ver 1.1  2003. 11
6-25
DCR-PC330/PC330E
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
19 (Note2)
Adjustment Address
13 to 18, 92
24 to 27
Specified Value 1
D6 to DA
Specified Value 2
26 to 2A
Specified Value 3
D3 to DD
Specified Value 4
23 to 2D
Note1: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
6D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note3)
5
6
01
00
Set the data, and press PAUSE
button.
Note3: The adjustment data will be automatically input to page: F, address:
13 to 18, 92 and to page: 19, address: 24 to 27.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
0
10
00
Set the data.
3
6
01
01
Set the data, and press PAUSE
button.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
6
6
01
01
Set the data, and press PAUSE
button.
7
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
8
6
01
6B
Set the data, and press PAUSE
button.
9
6
01
69
Set the data, and press PAUSE
button.
10
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
11
6
01
6B
Set the data, and press PAUSE
button.
12
1
Check that the ND display data
(Note1) satisfies the specified
value.4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
Page of 74
Display