Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc330-dcr-pc330e-sm4.pdf
Date

Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ▷ View online

6-30
DCR-PC330/PC330E
8. Flange Back Check
Subject
Siemens star
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE end.
Note1: The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Note2: When the auto focus is ON, the lens can be checked if it is focused
or not by observing the data on the page 1 of the adjustment remote
commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Select page: 6, address: 40, and set data: 01.
2)
Select page: 6, address: 41, and set data: 01.
3)
Place the Siemens star 2.0m from the front of the lens.
4)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note2).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments:
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
9. ND ON/OFF Adjustment
Adjustment to reduce the difference in the amount of light when
the ND filter is on and when the ND filter is off.
Subject
Clear chart (All white frame)
(33cm from the front of the lens)
(Note1)
Adjustment Page
19 (Note2)
Adjustment Address
28
Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Note2: When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... WIDE end
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
F
A1
Write down the data.
4
F
A1
C0
Set the data, and press PAUSE
button.
5
6
2C
01
Set the data.
6
6
01
71
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: 19,
address: 28.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
2C
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
F
A1
Set the data that is written down
at “Adjusting method”, and press
PAUSE button.
5
0
01
00
Set the data.
6-31
DCR-PC330/PC330E
10. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart (All white frame)
(33cm from the front of the lens)
(Note1)
Adjustment Page
F
Adjustment Address
19
Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Note2: This adjustment should be carried out upon completion of “Flange
Back Adjustment”.
Note3: The data of page: 0, address: 10 must be “00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5: NTSC model: DCR-PC330
PAL model: DCR- PC330E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... WIDE end
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
2C
01
Set the data.
3
6
40
01
Set the data.
4
6
96
Set the following data.
1A (NTSC), 14 (PAL)
5
6
97
00
Set the data.
6
6
01
6F
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note6)
Note6: The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
2C
00
Set the data.
2
6
40
00
Set the data.
3
6
96
00
Set the data.
4
6
97
00
Set the data.
5
6
01
00
Set the data, and press PAUSE
button.
6
0
01
00
Set the data.
11. Mechanical Shutter Adjustment
Adjustment Page
F
Adjustment Address
76 to 8B
Note: The data of page: 0, address: 10 must be “00”.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 76 to 8B.
Note: Press the PAUSE button of the adjustment remote commander each
time to set the data.
Address
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
NTSC
B9
00
81
00
64
00
50
00
40
00
53
61
60
59
50
1E
7E
80
80
80
80
7F
PAL
99
00
6A
00
53
00
42
00
36
00
50
60
55
57
4D
1E
81
80
80
80
80
80
Data
3)
Select page: 0, address: 01, and set data: 00.
6-32
DCR-PC330/PC330E
12. Picture Frame Setting
(Color Reproduction Adjustment Frame)
When performing “Color Reproduction Adjustment” and “Mixed
Color Compensation Adjustment”, set the picture frame to “Color
reproduction adjustment frame”.
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Oscilloscope,
TV monitor (Under scan mode)
Specified Value
A=B, C=D, E=F
Note1: This adjustment should be carried out upon completion of “HALL
Adjustment” and “Flange Back Adjustment”.
Note2: The data of page: 0, address: 10 must be “00".
Note3: Displayed data of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
Order Page Address Data
Procedure
1
0
03
18
Set the data.
2
1
Read XH data and XL data.
(Note3)
3
0
03
22
Set the data.
4
1
Read YH data and YL data.
(Note3)
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
Set the data. (Note4)
2
6
91
XH
Set the data. (Note4)
3
6
92
YL
Set the data. (Note4)
4
6
93
YH
Set the data. (Note4)
5
6
01
79
Set the data, and press PAUSE
button.
Note4: XL, XH, YL and YH are the data read in the “Setting method”.
Note5: This picture frame setting can be released in the following method.
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
90
00
Set the data.
3
6
91
00
Set the data.
4
6
92
00
Set the data.
5
6
93
00
Set the data.
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-33
DCR-PC330/PC330E
13. Mixed Color Compensation Adjustment
Compensate the mixed colors of the CCD color filters so that proper
color reproduction is produced.
Subject
Mixed color compensation chart
(Color reproduction adjustment frame)
(1.0m from the front of the lens)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
14 (Note2)
Adjustment Address
98 to 9F, A8 to B7
Specified Value 1
bit15 is “1”
Note1: This adjustment should be carried out upon completion of “CCD
Output 2ch Matching Adjustment”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
XL
Set the data. (Note5)
3
6
91
XH
Set the data. (Note5)
4
6
92
YL
Set the data. (Note5)
5
6
93
YH
Set the data. (Note5)
6
6
01
79
Set the data, and press PAUSE
button.
7
Check that the picture frame
becomes “Color reproduction
adjustment frame”.
(Refer to “12. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.)
Note5: XL, XH, YL and YH are the data read in the “12. Picture Frame
Setting (Color Reproduction Adjustment Frame)”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
D5
Set the data, and press PAUSE
button.
4
6
01
D7
Set the data, and press PAUSE
button.
5
0
03
33
Set the data.
6
6
02
Check that the data is “01”.
(Note6)
7
1
Check that bit15 of the display
data (Note4) is “1”.  (Note7)
Note6: The adjustment data will be automatically input to page: 14,
address: 98 to 9F, A8 to B7.
Note7: When bit15 of the display data is “1”, the display data is “8000”
to “FFFF”.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
0
01
00
Set the data.
8
0
03
00
Set the data.
Page of 74
Display

Click on the first or last page to see other DCR-PC330 / DCR-PC330E (serv.man4) service manuals if exist.