Movie / SECTION 6 ADJUSTMENTS
File
dcr-pc330-dcr-pc330e-sm4.pdf
Date

Sony DCR-PC330 / DCR-PC330E (serv.man4) Service Manual ▷ View online

6-34
DCR-PC330/PC330E
14. Picture Frame Setting (All White Frame)
When performing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, set the picture frame to “All white frame”.
Subject
Clear chart (All white frame)
(1.0m from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
TV monitor (Under scan mode)
Specified Value
Whole of the screen is white
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Setting method:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
70
Set the data.
3
6
91
02
Set the data.
4
6
92
00
Set the data.
5
6
93
46
Set the data.
6
6
01
79
Set the data, and press PAUSE
button.
7
Check that the whole of the
screen is white.
8
Perform the following
adjustments.
Processing after Completing Adjustments
After completing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, release the data setting.
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
00
Set the data.
3
6
91
00
Set the data.
4
6
92
00
Set the data.
5
6
93
00
Set the data.
6
0
01
00
Set the data.
15. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart (All white frame)
(1.0m from the front of the lens)
(Note3)
Adjustment Page
F
14 (Note2)
Adjustment Address
2E to 31
E8 to F3
Note1: This adjustment should be carried out upon completion of “ND
ON/OFF Adjustment”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “14. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
Wait for more than 2 sec.
5
6
01
43
Set the data, and press PAUSE
button.
6
6
01
41
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
Perform “LV Standard Data
Input”.
4
If finish the camera system
adjustments, perform
“Processing after Completing
Adjustments” of “14. Picture
Frame Setting (All White
Frame)”.
Ver 1.1  2003. 11
6-35
DCR-PC330/PC330E
16. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame)
(1.0m from the front of the lens)
(Note4)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of “Color
Reproduction Adjustment”.
Note2: The data of page: 0, address: 10 must be “00".
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform “14. Picture Frame Setting (All White Frame)” before
this adjustment.
Note5: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
Wait for more than 6 sec.
4
6
30
01
Set the data, and press PAUSE
button.
5
6
40
01
Set the data, and press PAUSE
button.
6
6
01
0D
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note6)
8
0
03
1E
Set the data.
9
1
Check that the display data
(Note5) satisfies the specified
value.
Note6: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
30
00
Set the data.
3
6
40
00
Set the data.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
6
Perform “Auto White Balance
Adjustment”.
7
If finish the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“14. Picture Frame Setting (All
White Frame)”.
6-36
DCR-PC330/PC330E
17. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart (All white frame)
(1.0m from the front of the lens)
(Note3)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14 (Note2)
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Perform  “14. Picture Frame Setting (All White Frame)” before
this adjustment.
Note4: NTSC model: DCR-PC330
PAL model: DCR-PC330E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”.
2
Place the C14 filter for color
temperature correction on the
lens.
3
0
01
01
Set the data.
4
Wait for more than 2 sec.
5
0
10
00
Set the data.
6
F
44
2C
Set the data, and press PAUSE
button.
7
F
45
Set the following data, and press
PAUSE button.
  C0 (NTSC), 80 (PAL)
8
F
46
5A
Set the data, and press PAUSE
button.
9
F
47
C4
Set the data, and press PAUSE
button.
10
6
01
47
Set the data, and press PAUSE
button.
11
6
01
45
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
32 to 35, 44 to 47 and to page: 14, address: F4 to FF
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Remove the C14 filter.
5
Perform “White Balance
Check”.
6
If finish the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“14. Picture Frame Setting (All
White Frame)”.
Ver 1.1  2003. 11
6-37
DCR-PC330/PC330E
18. White Balance Check
Subject
Clear chart (All white frame)
(1.0m from the front of the lens)
(Note3)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of Display data of
AUDIO/VIDEO
page 1 (Note4)
jack
Measuring Instrument
Vectorscope
Adjustment remote
commander
Specified Value 1
Fig. 6-1-13 (A) to (B)
Specified Value 2
R ratio: 2C80 to 2D00 (NTSC)
2C40 to 2CC0 (PAL)
B ratio: 5A80 to 5B00
Specified Value 3
8000 to 8BC0
Note1: Perform “Auto White Balance Adjustment” before this adjustment.
If not performed, R ratio data and B ratio data may not satisfy the
specified value 2.
Note2: The data of page: 0, address: 10 must be “00".
Note3: Perform “14. Picture Frame Setting (All White Frame)”.
Note4: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note5: NTSC model: DCR-PC330
PAL model: DCR-PC330E
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (Menu setting) .................................... OFF
5)
STEADY SHOT (Menu setting) ...................................... OFF
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”.
Outdoor white balance check
2
Place the C14 filter on the lens.
3
Wait for more than 3 sec.
4
6
11
40
Set the data, and press PAUSE
button.
5
6
01
3F
Set the data, and press PAUSE
button.
6
0
03
04
Set the data.
7
1
Check that the display data
(Note4) satisfies the R ratio
specified value.
8
0
03
05
Set the data.
9
1
Check that the display data
(Note4) satisfies the B ratio
specified value.
10
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-13 (A).
11
6
01
00
Set the data, and press PAUSE
button.
12
6
11
00
Set the data, and press PAUSE
button.
13
Remove the C14 filter.
Indoor white balance check
14
6
01
0F
Set the data, and press PAUSE
button.
15
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-13 (B).
16
6
01
00
Set the data, and press PAUSE
button.
LV data check
17
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
18
0
03
06
Set the data.
19
1
Check that the display data (Note2)
satisfies the specified value 3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
Remove the ND filter.
Fig. 6-1-13 (B).
Fig. 6-1-13 (A).
R-Y
2mm
B-Y
2mm
R-Y
B-Y
2mm
3mm
3mm
Page of 74