Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc1000-dcr-hc1000e-sm4.pdf
Date

Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ▷ View online

6-10
DCR-HC1000/HC1000E
1-2-2.
INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA
Note:
When reading or writing the A, B, D page data, select page: 0,
address: 10, and set data: 00.
When reading or writing the 1A or 1B page data, select page: 0,
address: 10, and set data: 01, then select A or B page. The 1A or 1B
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the A, B, D, 1A, 1B Page Data
Note1:
If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 70
Adjusting page
1A
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
04
Set the following data.
80 (DCR-HC1000 (NTSC))
81 (DCR-HC1000E (PAL))
4
7
01
XX
Set the data. (Note2)
5
7
00
01
Set the data, and press PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
D, 1A, 1B Page Data”.
Note2:
XX=20: Initializing A page
XX=21: Initializing B page
XX=22: Initializing D page
XX=23: Initializing 1A page
XX=24: Initializing 1B page
XX=25: Initializing A and 1A pages
XX=26: Initializing B and 1B pages
XX=28: Initializing A, B, D, 1A and 1B pages
2. Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the A, B, D page data, select page: 0, address:
10, and set data: 00.
3)
When changing the 1A, 1B page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, D, 1A, 1B
Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, B, D, 1A, 1B page data”, check that the data of
addresses: 1A to 4F of A page and the data of addresses: 12 to 19 of
D page are same as those of the same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
6-11
DCR-HC1000/HC1000E
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
5. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Table. 6-1-2.
4. B Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Initial value
NTSC PAL
00 to 0F
10
11 to 17
18
19 to 28
29
2A to 2E
2F
30
31
32 to 4F
50
51 to 59
5A
5B
5C
5D
5E to 8F
90
91
92
93
94 to CF
D0
D1
D2
D3 to D4
D5
D6
D7
D8
D9
DA to FF
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Touch panel adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
00
DD
1C
C7
2A
00
E0
1D
D4
24
Address
00 to 04
05
06
07
08 to FF
Remark
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-3.
Table. 6-1-4.
6. 1A Page Table
Note1:
When reading or writing the 1A page data, select page: 0, address:
10, and set data: 01, then select A page. The 1A page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to 0F
10 to 13
14
15
16
17 to 27
28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 44
45
46 to 47
48 to 49
4A
4B
4C
4D
4E
4F
50 to 56
57
68 to 70
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-5.
7. 1B Page Table
Note1:
When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”).
Address
00 to 04
05
06 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-6.
Address
00 to FF
Remark
Fixed data-1
6-12
DCR-HC1000/HC1000E
1-2-3.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1:
If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2:
If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-13
DCR-HC1000/HC1000E
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-7.
Address
00 to 29
2A
2B to 3F
40
41 to 43
44
45
46 to 79
7A
7B to 83
84
85
86
87
88
89
8A
8B
8C to 94
95
96 to AB
AC
AD to B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC to C5
C6
C7 to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF to E2
E3
E4
E5 to E7
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F9
FA
FB
FC to FF
Remark
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Page of 70
Display

Click on the first or last page to see other DCR-HC1000 / DCR-HC1000E (serv.man4) service manuals if exist.