DOWNLOAD Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ↓ Size: 1020.41 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC1000 DCR-HC1000E (serv.man4)
Pages
70
Size
1020.41 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc1000-dcr-hc1000e-sm4.pdf
Date

Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ▷ View online

6-26
DCR-HC1000/HC1000E
7. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note1:
The following adjustments should be carried out upon completion
of “Flange back adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FOCUS .................................................................. MANUAL
3)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
4)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
Procedure
1
6
2C
01
Set the data.
2
6
90
CB
Set the data.
3
6
91
01
Set the data.
4
6
92
B6
Set the data.
5
6
93
64
Set the data.
6
6
01
79
Set the data, and press PAUSE
button.
7
Adjust the camera direction, and
set to the specified position.
8
Perform the following adjustments.
(Note3)
Note3:
When using the clear chart, remove the color bar chart from the
pattern box and insert a clear chart in its place. (Do not perform
zoom operations during this time.)
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-10.
2. Vertical period
Fig. 6-1-11.
Check on the monitor TV (Underscanned mode)
Fig. 6-1-12.
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6-27
DCR-HC1000/HC1000E
8. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
2A to 2D
Note1: After the power is turned on, this adjustment can be done only
once.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FOCUS .................................................................. MANUAL
3)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
4)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
11
Set the data, and press PAUSE
button.
3
6
01
0B
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
2A to 2D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Have to perform “LV Standard
Data Input”.
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
19
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: NTSC model : DCR-HC1000
PAL model
: DCR-HC1000E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FOCUS .................................................................. MANUAL
3)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
4)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
23
Set the data.
3
E
53
DD
Set the data.
4
Check that the white balance is
stabilized.
5
6
01
00
Set the data.
6
6
96
Set the following data.
2A (NTSC), 14 (PAL)
7
6
97
00
Set the data.
8
6
01
6F
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
E
53
DC
Set the data.
5
0
01
00
Set the data.
Ver 1.1  2004. 07
6-28
DCR-HC1000/HC1000E
11. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note3)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1: This adjustments should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FOCUS .................................................................. MANUAL
3)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
4)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check the picture frame.
(Refer to “7. Picture Frame
Setting”.)
2
0
01
01
Set the data.
3
6
30
01
Set the data.
4
6
01
0D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note5)
6
0
02
06
Set the data.
7
0
03
1E
Set the data.
8
1
Check that the display data (Note4)
satisfies the specified value.
Note5: The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
30
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
10. F No. & ND Light Quantity Standard Data Input
Compensate the unevenness of the light quantity of the iris meter
and ND filter.
Adjustment Page
F
Adjustment Address
1C to 23
Note1: The data of page: 0, address: 10 must be “00”.
Note2: NTSC model : DCR-HC1000
PAL model
: DCR-HC1000E
Switch setting:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 1C to 23.
Note: Press the PAUSE button each time to set the data.
3)
Select page: 0, address: 01, and set data: 00.
PAL
99
8F
87
83
90
89
89
88
Address
1C
1D
1E
1F
20
21
22
23
NTSC
99
8F
87
83
90
89
89
88
Data
Ver 1.1  2004. 07
6-29
DCR-HC1000/HC1000E
12. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
3C to 3F, 40 to 43
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: The data of page: 0, address: 10 must be “00”.
Note4: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
FOCUS .................................................................. MANUAL
3)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
4)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
F
3C
Set the  following data, and
press PAUSE button.
2B (NTSC), 2C (PAL)
4
F
3D
Set the  following data, and
press PAUSE button.
F4 (NTSC), 34 (PAL)
5
F
3E
59
Set the data, and press PAUSE
button.
6
F
3F
30
Set the data, and press PAUSE
button.
7
6
01
83
Set the data, and press PAUSE
button.
8
6
01
81
Set the data, and press PAUSE
button.
9
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
40 to 43.
Note6: NTSC model : DCR-HC1000
PAL model
: DCR-HC1000E
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Remove the C14 filter.
Ver 1.1  2004. 07
Page of 70
Display