DOWNLOAD Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ↓ Size: 1020.41 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC1000 DCR-HC1000E (serv.man4)
Pages
70
Size
1020.41 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc1000-dcr-hc1000e-sm4.pdf
Date

Sony DCR-HC1000 / DCR-HC1000E (serv.man4) Service Manual ▷ View online

6-18
DCR-HC1000/HC1000E
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Initial value
NTSC PAL
00 to 0F
10 to 12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24 to 2A
2A
2B
2C
2D
2E to 35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44 to 5F
60
61
62
63
64
65
66
67
Fixed data-1
HALL adj.
MAX GAIN adj.
LV standard data input
F No. & ND light quantity
standard data input
Fixed data-1
AWB standard data input
Fixed data-1
Strobe white balance adj.
Color reproduction adj.
Auto white balance adj.
Fixed data-1
Flange back adj.
Address
Remark
Initial value
80
90
18
75
4A
89
80
80
7A
80
80
80
80
80
80
80
80
14
17
04
79
2D
64
01
E8
1B
24
2B
F4
59
30
0A
19
07
DD
11
EB
53
0A
1E
AC
00
00
80
90
18
75
4A
89
80
80
7A
80
80
80
80
80
80
80
80
14
17
04
79
2D
64
00
EF
1E
2F
2B
F4
59
30
0A
19
07
DD
11
EB
53
0A
1E
AC
00
00
Initial value
NTSC PAL
Address
Remark
Initial value
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D to 83
84
85
86
87
88 to 89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
00
00
86
19
19
38
00
00
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
80
80
50
50
01
E0
80
80
80
20
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
86
19
19
38
00
00
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
80
80
50
50
01
E0
80
80
80
20
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Flange back adj.
Flange back/MR adj.
MR adj.
Fixed data-1
PSD sensor gain adj.
Angular velocity sensor
sensitivity adj.
Fixed data-1
Strobe light level adj.
Mechanical shutter adj.
6-19
DCR-HC1000/HC1000E
Table. 6-1-12.
5. 1E Page Table
Note1:
When reading or writing the 1E page data, select page: 0, address:
10, and set data: 01, then select E page. The 1E page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Initial value
NTSC PAL
Address
Remark
Initial value
Mechanical shutter adj.
Flange back adj.
HALL adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
00
00
00
00
00
00
89
17
00
00
00
00
00
00
89
17
F page
A2
A3
A4
A5
A6
A7
A8
A9
AA to B3
B4
B5
B6
B7
B8
B9 to FF
Address
00 to 02
03
04 to 08
09
0A to 2D
2E
2F to 69
6A
6B
6C to 6D
6E
6F to 74
75
76
77
78
79 to C9
CA
CB
CC
CD
CE
CF
D0 to E5
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
6. 1F Page Table
Note1:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
1E, 1F Page Data”).
Address
00 to 69
6A
6B to B8
B9
BA to EE
EF
F0 to F4
F5
F6 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-13.
Table. 6-1-14.
6-20
DCR-HC1000/HC1000E
1
12
36
25
48
13
37
24
1
12
36
25
48
13
37
24
1
12
36
25
48
13
37
24
IC5003
IC5004
IC5005
VC-366 board (SIDE A)
 
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for “54MHz/
66MHz Origin Oscillation Check”), check that the specified values
of “VIDEO SYSTEM ADJUSTMENTS” are satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
1. 54MHz/66MHz Origin Oscillation Check (VC-366 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Note1:
54MHz ..................................................... DCR-HC1000E (PAL)
66MHz .................................................... DCR-HC1000 (NTSC)
Subject
Not required
Measurement Point
Pin qh of IC5003
Or Pin qh of IC5004
Or Pin qh of IC5005
Measuring Instrument
Frequency counter
Specified Value
f=33000000 ± 664Hz (NTSC)
f=27000000 ± 542Hz (PAL)
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER ....................................................... CAMERA-TAPE
Adjusting method:
Check that the frequency (f) satisfies the specified value.
Fig. 6-1-8.
6-21
DCR-HC1000/HC1000E
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18, A7 to A9
Specified Value 1
15 to 19
Specified Value 2
89 to 8D
Specified Value 3
89 to 8D
Specified Value 4
15 to 19
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
POWER ....................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
17
Set the data.
3
6
95
8B
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
6
6
01
00
Set the data, and press PAUSE
button.
Note4:
The adjustment data will be automatically input to page: F, address:
13 to 18, A7 to A9.
Checking method:
Order Page Address Data
Procedure
1
0
02
06
Set the data.
2
0
03
03
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
01
01
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
6
6
01
03
Set the data, and press PAUSE
button.
7
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
8
6
01
69
Set the data, and press PAUSE
button.
9
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
10
6
01
6B
Set the data, and press PAUSE
button.
11
1
Check that the ND display data
(Note1) satisfies the specified
value.4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
03
00
Set the data.
5
0
01
00
Set the data.
Page of 70
Display