4-12
SAL1635Z2 (Vario-Sonnar 2.8/16-35 ZA SSM II) (Vario-Sonnar T* 16-35mm F2.8 ZA SSM II)
4.  Confirm that all of the items are set, and click [Save].
 
 Fig. 
4-7-7
5.  Click the [Finish] to close the SETUP window.
4-7-4. About Inspection Procedure of Lens Adjustment Program (ACSSM-S-VerXXX)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the 
inspection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-8. HALF COMPLETION ADJUSTMENT/INSPECTION
Equipment
• Personal Computer
•  Finished Inspection JIG II (AC 100 - 240 V)
•  Lens Adjustment Program
ACSSM-S-VerXXX
•  Adhesive Bond (B-10) 
•  Half Completion JIG
Note:
  Please make the Half Completion JIG in each service station.
 
For details of the jig making method, refer to  4-1-1. List of Service Tools and Equipments  Note 5.
4-8-1. Preparation
1. Preparation
1)  Attach the lens to the equipment. (Refer to  4-7-2. Connection of Finished Inspection JIG
/Half Completion JIG and Starting of Lens 
Adjustment Program (ACSSM-S-VerXXX) .)
2)  Start up the lens adjustment program (ACSSM-S-VerXXX.exe).
3)  Click [Setup] and perform the initial setting. (Refer to  4-7-3. Initial Setting of Lens Adjustment Program (ACSSM-S-VerXXX) )
Note:
  When the Multi Serial window opens, take the following actions.
Process No.
You need not enter process number.
Serial No.
When the mount block assy is replaced, enter a serial number.
 Table 
4-8-1
 
 Fig. 
4-8-1
4-8-2. Half Completion Inspection Item
Perform Half Completion Adjustment/Inspection items in the order as shown below.
1)  Adjust Focus Brush
2) Focus-Adj Position
3)  Focus Pattern (Motor)
4)  MR Waves Check (Manual)
5)  Adjust & Check MR
6)  Adjust Driving Frequency & Gain
7)  Focus Driving Trial Run
 
 
Fig. 4-8-2
4-13
SAL1635Z2 (Vario-Sonnar 2.8/16-35 ZA SSM II) (Vario-Sonnar T* 16-35mm F2.8 ZA SSM II)
4-8-3. MR Waveforms Inspection/Adjustment
1. Adjustment/Checking procedure
1)  Click [Adjust & Check MR]. 
2)  The frequency input window is displayed, input the number (upper three digits) written on the SSM flexible wire.  
Example: In case the number written in the flexible wire is  180076 .
180076
 Fig. 
4-8-3
3)  When no problem is found in [Adjust & Check MR],  OK  appears.
 
 Fig. 
4-8-4
4)  If the [NG] button is displayed, perform the  2. Position Adjustment of MR Sensor .
2.  Position Adjustment of MR Sensor 
If [Adjust & Check MR] is not good, perform the following procedures for position adjustment of MR sensor. 
1)  Click [MR Waves Check (manual)] on the window and display the MR waveform screen.
2)  Check waveform changes by operating the focus linkage ring.
 Fig. 
4-8-5
3)  Confirm that the waveform is larger than the inner circle, and then click [OK].
Note:
  The waveform is not necessarily displayed at the center of the window.
 
There is no problem when the waveform is larger than the inner circle even if the waveform is not positioned at the center of the window.
4)  In case that  OK  does not appear on both the Amp and Mean columns in all ranges while rotating the focus in the MR wave check, 
adjust by moving the position of the MR sensor.
5)  After adjustment, apply the adhesive bond (B-10) to the head of screw.
MR Block Assy
Apply the adhesive 
bond (B-10).
Adjustment procedure: Loosen two screws and adjust by moving 
                                     the position of the MR sensor (MR Block Assy)
 Fig. 
4-8-6
4-14
SAL1635Z2 (Vario-Sonnar 2.8/16-35 ZA SSM II) (Vario-Sonnar T* 16-35mm F2.8 ZA SSM II)
4-8-4. Focus Brush Position Check/Adjustment
1. Preparations
1)  Disassemble or assemble the inspecting lens to the state shown in Fig.4-8-7.
 
Brush
Screw
 Fig. 
4-8-7
2)   Make up as shown in Fig. 4-7-2 referring (Refer to  4-7-2. Connection of Finished Inspection JIG
/Half Completion JIG and Starting 
of Lens Adjustment Program (ACSSM-S-VerXXX) .).
2. Adjustment/Inspection Method
1)  Click [START [Ent]] or [Adjust Focus Brush]. 
2)  Operate as instructed in the menu.
3)  Set the focus to infinity end.
 
 Fig. 
4-8-8
4)  When the focus locates on the focus adjustment end, the pop-up window shown below appears.At this position, tighten the screw to fix 
the brush.
 
 Fig. 
4-8-9
5)  Apply the adhesive bond (B-10) to the head of screw as shown in Fig. 4-8-10.
 
Apply the 
adhesive bond (B-10)
Brush
 Fig. 
4-8-10
6)  Rotate the focus from 
 (infinity) end to near end and then from near end to 
 (infinity) end to confirm the focus brush position once 
again.
4-8-5. Focus pattern (Motor) inspection
1. Preparations
Set the 1.Preparation of  4-8-4. Focus Brush Position Check/Adjustment .
2. Checking procedure
1)  Click [Focus pattern (Motor)].
Note: 
When the Multi Serial window opens, take the following actions.
Process No.
You need not enter process number.
Serial No.
When the mount block assy is replaced, enter a serial number.
 Table 
4-8-1
 
 Fig. 
4-8-11
4-15
SAL1635Z2 (Vario-Sonnar 2.8/16-35 ZA SSM II) (Vario-Sonnar T* 16-35mm F2.8 ZA SSM II)
2)  SSM frequency input screen is displayed. Make sure that the number (upper three digits) written in the flexible wire of the ultrasonic 
motor (stator) is displayed.
 
 Fig. 
4-8-12
 
180083
 Fig. 
4-8-13
3
 After inputting  the number, the following window is displayed.
 
 Fig. 
4-8-14
4)  When the inspection finishes normally,  OK  is displayed. Then, press the ENTER key to return to the initial menu.
 
 Fig. 
4-8-15
4-8-6. Focus drive trial run
1. Preparations
Set the 1.Preparation of  4-8-4. Focus Brush Position Check/Adjustment .
2. Checking procedure
1)  Click [Focus drive trial run].
Note: 
When the Multi Serial window opens, take the following actions.
Process No.
You need not enter process number.
Serial No.
When the mount block assy is replaced, enter a serial number.
 Table 
4-8-2
 
 Fig. 
4-8-16
2)   SSM frequency input screen is displayed. Make sure that the number (upper three digits) written in the flexible wire of the ultrasonic 
motor (stator) is displayed.
 
 Fig. 
4-8-17
 
180083
 Fig. 
4-8-18
3)  When the focus locates on the focus adjustment end, the pop-up window shown below appears. At this position, tighten the screw to 
fix the brush.
 
 Fig. 
4-8-19
4)  When the inspection finishes normally,  OK  is displayed. Then, press the ENTER key to return to the initial menu.
 
 Fig. 
4-8-20
Page of 60
Display