DOWNLOAD Sony DSC-W300 (serv.man3) Service Manual ↓ Size: 800.98 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-W300 (serv.man3)
Pages
37
Size
800.98 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-w300-sm3.pdf
Date

Sony DSC-W300 (serv.man3) Service Manual ▷ View online

6-32
DSC-W300_ADJ
5.
Aging
On the AGING screen, various types of aging can be executed.
Select the type of aging to be executed with the Aging Mode Se-
lect buttons.
Supply the power not from an AC adapter but from the fully charged
battery and execute the aging until the battery end, so that its bat-
tery use time and how many pictures the camera can record/play
back can be checked.
During the execution of aging, the camera automatically repeats
recording/playback.
During the recording, if the recording memory capacity becomes
full, its memory is automatically formatted.
Accordingly, when executing the aging, insert the Memory Stick
into the camera.
[Preparation]
For the aging, set the camera as follows:
Switch Setting
1) Mode Dial .................................................... Auto Adjustment
Home Items
1) AF Mode
(Settings – Shooting Settings – Shooting Settings 1) .... Single
Menu Items
1) REC Mode ................................................................... Normal
(1) 10MODE
In the 10MODE, perform continuous recording in accordance with
the CIPA Standard. When the 10MODE starts, the following op-
eration is repeated until the battery end.
1) The zoom moves to the TELE end.
2) The camera records a still picture with a strobe light flashed at
the maximum level.
3) The camera stands by for the time (sec.) set to the “Rec Inter-
val”.
4) The zoom moves to the WIDE end.
5) The camera records a still picture without flashing a strobe
light.
6) The camera stands by for the time (sec.) set to the “Rec Inter-
val”.
7) Each time 10 still pictures are recorded, the power is turned
off, and after the time (min.) set to the “Power Off Interval”,
the power is turned on again.
At the start of 10MODE, the counter in the camera is initialized.
This counter counts the number of recording times during the ex-
ecution of 10MODE, and it holds the counts even during the power
off.
Aging Mode Select button
6-33
DSC-W300_ADJ
10MODE screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Rec Interval setting and display
The setting of recording interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
3
Power Off Interval setting and display
The setting of power off interval (min.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
4
[START] button
The settings of parameters specified by the Rec Interval and
Power Off Interval for execution of 10MODE are sent to the
camera.
The 10MODE starts when the camera power is turned off once
and then on again.
The settings for execution of 10MODE are held until the cam-
era detects the battery end. They cannot be reset by the power
off or RESET button. To interrupt the 10MODE, use the [STOP]
button.
5
[STOP] button
The settings for execution of 10MODE are reset.
6
[GET] button
After the 10MODE was executed, the number of recording
times is got from the counter in the camera. The result is dis-
played in the “Count” display field.
7
Count display
The number of recording times got by the [GET] button is dis-
played.
(2) AGING_REC
In the AGING_REC mode, still pictures are continuously recorded
at the interval (sec.) set to the “Rec Interval”.
At the start of AGING_REC, the counter in the camera is initial-
ized. This counter counts the number of recording times during
the execution of AGING_REC, and it holds the counts even dur-
ing the power off.
AGING_REC screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Rec Interval setting and display
The setting of recording interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
3
[START] button
The AGING_REC starts. In the AGING_REC mode, the ag-
ing starts immediately when the [START] button is clicked.
At the battery end, the AGING_REC stops. To interrupt the
AGING_REC, use the [STOP] button, though the AGING_REC
stops also by the power off or RESET button.
4
[STOP] button
The AGING_REC stops.
5
[GET] button
After the AGING_REC was executed, the number of record-
ing times is got from the counter in the camera. The result is
displayed in the “Count” display field.
6
Count display
The number of recording times got by the [GET] button is dis-
played.
6
4
5
1
7
2 3
5
3
4
1
6
2
6-34
DSC-W300_ADJ
(3) AGING_MREC
In the AGING_MREC mode, motion pictures are continuously
recorded for the time (sec.) set to the “Rec Time” at the interval
(sec.) set to the “Rec Interval”.
At the start of AGING_MREC, the counter in the camera is ini-
tialized. This counter counts the number of recording times dur-
ing the execution of AGING_MREC, and it holds the counts
even during the power off.
AGING_MREC screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Rec Time setting and display
The setting of recording time (sec.) is displayed. The setting
can be changed by entering a numeric value in this field.
3
Rec Interval setting and display
The setting of recording interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
4
[START] button
The AGING_MREC starts. In the AGING_MREC mode, the
aging starts immediately when the [START] button is clicked.
At the battery end, the AGING_MREC stops. To interrupt the
AGING_MREC, use the [STOP]  button, though the
AGING_MREC stops also by the power off or RESET button.
5
[STOP] button
The AGING_MREC stops.
6
[GET] button
After the AGING_MREC was executed, the number of record-
ing times is got from the counter in the camera. The result is
displayed in the “Count” display field.
7
Count display
The number of recording times got by the [GET] button is dis-
played.
(4) AGING_PB
In the AGING_PB mode, pictures are continuously played back at
the interval (sec.) set to the “Play Back Interval”.
At the start of AGING_PB, the counter in the camera is initial-
ized. This counter counts the number of play back times during
the execution of AGING_PB, and it holds the counts even during
the power off.
AGING_PB screen and functions of each item
1
[Preparation] button
Notes for aging is displayed.
2
Play Back Interval setting and display
The setting of play back interval (sec.) is displayed. The set-
ting can be changed by entering a numeric value in this field.
3
[START] button
The AGING_PB starts. In the AGING_PB mode, the aging
starts immediately when the [START] button is clicked.
At the battery end, the AGING_PB stops. To interrupt the
AGING_PB, use the [STOP] button, though the AGING_PB
stops also by the power off or RESET button.
4
[STOP] button
The AGING_PB stops.
5
[GET] button
After the AGING_PB was executed, the number of play back
times is got from the counter in the camera. The result is dis-
played in the “Count” display field.
6
Count display
The number of play back times got by the [GET]  button is
displayed.
6
4
5
1
7
2 3
5
3
4
1
6
2
6-35E
DSC-W300_ADJ
2-3.
DATA  BACKUP
With the “DATA BACKUP”, the adjustment data in the camera
can be backed up in the PC as a file.
The adjustment data that can be backed up are as follows.
System Control Section:
1) Video System Adjustments
2) LCD System Adjustments
Camera Control Section:
1) Camera System Adjustments
1.
Function of Each Button on Data Backup Screen
Click the [DATA BACKUP] button on the Main Menu screen, and
the “DATA BACKUP” screen in Fig. 6-2-3 will appear.
Fig. 6-2-3
1
[To Menu] button
Return to the main menu.
2
[Data Read and Save] button
Read the adjustment data from the camera and save them in
PC as a file.
Default file name is as follows:
3
[Data Load and Write] button
Load the adjustment data from the file saved in PC and write
them to the camera.
DSC-W300_ADJBAK_xxxxxxxx_yyyymmdd.dat
Date
USB serial number
Data name
1
2
3
Page of 37
Display

Click on the first or last page to see other DSC-W300 (serv.man3) service manuals if exist.