DOWNLOAD Sony DSC-W300 (serv.man3) Service Manual ↓ Size: 800.98 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-W300 (serv.man3)
Pages
37
Size
800.98 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-w300-sm3.pdf
Date

Sony DSC-W300 (serv.man3) Service Manual ▷ View online

6-28
DSC-W300_ADJ
5.
Data Save Error
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
• Data writing to the flash memory failed.
• Connection is faulty.
• Power supply is not installed correctly.
Remedy
• On the SeusEX Operation screen, [Set] the
data to the pages and addresses displayed in
the message, and [Save] them. (Cancel manu-
ally the data setting during adjustment.)
• Check the connection.
• Install the power supply correctly.
1-8-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not op-
erate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown figures below. Click the [Release Data Set-
ting]  button to cancel the data setting. When the data setting is
cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred, the [Release Data Set-
ting] button is displayed in “white”.
To cancel the data setting, perform it on the SeusEX Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Video System Adjustment screen
Camera System Adjustment screen
How to cancel the data setting during 
adjustment is display here.
6-29
DSC-W300_ADJ
6-2. SERVICE  MODE
2-1.
APPLICATION  FOR  ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coeffi-
cients of signal processing, EVR data, etc. same as the adjustment
remote commander. The SeusEX performs two-way communica-
tion between PC and camera using the USB terminal. The two-
way communication result data can be written in the nonvolatile
memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camera with the USB cable.
3) Start the SeusEX on the PC.
4) Click  [Connect]  on the SeusEX screen. If the connection is
normal, the SeusEX screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note:
The SeusEX will go in “disconnect” state, if the cam-
era is turned off (for instance, by resetting the set). In
such a case, click [Connect] on the SeusEX screen to
restore the “connected” state.
Fig. 6-2-1
2.
Operation
• Block change
To  change the block, click [Block]  on the SeusEX screen and
enter the block to be changed. The block is displayed in hexa-
decimal notation.
• Page change
To change the page, click [Page] on the SeusEX screen and en-
ter the page to be changed. The page is displayed in hexadeci-
mal notation.
• Address change
To  change the address, click [Address]  on the SeusEX screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click [Set] on the SeusEX screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the EEPROM, click [Write] on the SeusEX
screen and enter the data value to be written.
To  write the data to the flash memory, change the data value
using the [Set] on the SeusEX screen and then click [Save] to
save the data.
• Data reading
The data displayed on the SeusEX screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SeusEX screen and update the displayed data.
6-30
DSC-W300_ADJ
2.
Switch Check
Click the [Switch Check] button on the SERVICE MODE screen,
and the “SWITCH CHECK” screen will appear.
Using method:
Click the [Start] button, and the switch check will start.
During execution of switch check, the pressed switch is displayed
in orange. Also, once the switch was pressed, its name characters
change to blue in color.
2-2.
SERVICE  MODE
1.
Function of Each Button on Service Mode Screen
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-2-2 will appear.
Fig. 6-2-2
1
[To Menu] button
Return to the main menu.
2
[Switch Check] button
“SWITCH CHECK” screen appears.
3
[LED Check] button
“LED CHECK” screen appears.
4
[Record Data] button
“RECORD DATA” screen appears.
5
[Aging] button
“AGING” screen appears.
1
4
5
2
3
6-31
DSC-W300_ADJ
4.
Record Data
Click the [Record Data] button on the SERVICE MODE screen,
and the “RECORD DATA” screen will appear.
The record data such as Lifetime counter is displayed.
Initializing method:
Click the [Clear Shot Count] button on the screen, and the Lifetime
Count data will be initialized.
3.
LED Check
Click the [LED Check] button on the SERVICE MODE screen, and
the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
Page of 37
Display

Click on the first or last page to see other DSC-W300 (serv.man3) service manuals if exist.