5-20
DSC-P71/P71M
8.
Auto White Balance 3200K Standard Data Input 
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Adjustment Page
F
Adjustment Address
70 to 77, B0, B2, B4
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
04
6
6
92
00
7
6
93
00
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to
“01”.
10
6
01
00
Press PAUSE button.
11
6
B6
03
12
6
37
02
13
6
01
0B
Press PAUSE button.
(Note 3)
14
6
02
Check the data changes to
“01”.
15
6
01
00
Press PAUSE button.
16
6
37
01
17
6
01
C1
Press PAUSE button.
(Note 3)
18
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F,  address: 70 to 77, B0, B2 and B4.”
RadarW
RadarW
RadarW
RadarW
RadarW
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
37
00
4
6
91
00
5
6
B6
00
6
Release the data setting
performed at step 1.
(Refer to page 5-13)
5-21
DSC-P71/P71M
9.
Auto White Balance 3200K Check 1
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 2)
(75 
Ω terminated)
Specified Value
R-Y level data:
FFFE to FFFF or 0000 to 0002
B-Y level data:
FFFE to FFFF or 0000 to 0002
Y level data: 40 to C0
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
04
6
6
92
00
7
6
93
00
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to
“01”.
10
6
01
00
11
6
16
04
12
6
B6
03
13
6
37
0D
14
6
01
C1
Press PAUSE button.
15
6
02
Check the data changes to
“01”.
16
0
03
2C
17
1
Check that the R-Y level data
(Note 2) satisfied the
specified value.
18
0
03
2D
19
1
Check that the B-Y level data
(Note 2) satisfied the
specified value.
20
0
03
33
21
1
Check that the Y level data
(Note 2) satisfied the
specified value.
22
Perform “Auto White
Balance 3200K Check 2”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
91
00
4
6
B6
00
5
Release the data setting
performed at step 1.
(Refer to page 5-13)
5-22
DSC-P71/P71M
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
16
00
3
6
37
00
4
6
2C
00
5
6
91
00
6
0
03
00
7
Release the data setting
performed at step 2.
(Refer to page 5-13)
10. Auto White Balance 3200K Check 2
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 3)
(75 
Ω terminated)
Specified Value
R ratio: 3F60 to 40A0
B ratio: 3F60 to 40A0
Note 1:
Perform this check after “Auto white Balance 3200K
Check 1” without a break.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Auto White Balance 3200K
check 1 is completed.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
Perform “Picture Frame
setting”. (Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to
“01”.
11
6
01
00
Press PAUSE button.
12
6
01
0F
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
0
03
04
15
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
16
0
03
05
17
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
5-23
DSC-P71/P71M
11. Auto White Balance 5800K Standard Data Input
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Adjustment Page
F
Adjustment Address
88 to 8F, A0 to A3, B1, B3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 5800K Standard Data Input” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
Perform “Picture Frame
setting”. (Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to
“01”.
11
6
01
00
Press PAUSE button.
12
F
A0
29
Press PAUSE button.
13
F
A1
98
Press PAUSE button.
14
F
A2
61
Press PAUSE button.
15
F
A3
08
Press PAUSE button.
16
6
B6
03
17
6
37
08
18
6
01
A5
Press PAUSE button.
(Note 2)
19
6
02
Check the data changes to
“01”.
20
6
01
00
Press PAUSE button.
21
6
37
07
22
6
01
C3
Press PAUSE button.
(Note 2)
23
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 88 to 8F, A0 to A3, B1 and B3.
RadarW
RadarW
RadarW
RadarW
RadarW
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
00
4
6
2C
00
5
6
91
00
6
Release the data setting
performed at step 2.
(Refer to page 5-13)
7
Remove the C14 filter on the
lens.
Page of 127