5-8
DSC-P71/P71M
3.
A Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the A Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of A Page Data”)
Address
Initial value
Remark
00, 01
Fixed data-1 (Initialized data)
02
00
Test mode
03 to 61
Fixed data-1 (Initialized data)
62
63
Fixed data-2
64 to 7F
Fixed data-1 (Initialized data)
80
8E
Backlight current adj. (BL L)
81
36
Backlight current adj. (BL H)
82
5E
VCO adj. (NTSC)
83
7C
VCO adj. (PAL)
84
A9
V-COM DC adj.
85
9B
D Range adj.
86
0A
Black limit adj.
87
3A
Psig Gray adj./V-COM adj.
88
90
89
83
White balance adj.
8A
4C
Contrast adj.
8B
48
Center voltage adj.
8C
8D
8E
Fixed data-2
8F
90 to 9F
Fixed data-1 (Initialized data)
A0
80
Composite video level adj.
A1, A2
Fixed data-1 (Initialized data)
A3
A4
Fixed data-2
A5 to A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
4.
D Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the D Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of D Page Data”)
Address
Initial value
Remark
10 to1F
Fixed data-1 (Initialized data)
20
Not used
21
00
Test mode
22 to 36
Fixed data-1 (Initialized data)
37 to 3F
Not used
40 to 5A
Fixed data-1 (Initialized data)
5B
Not used
5C to 73
Fixed data-1 (Initialized data)
1-2.
INITIALIZATION OF A, B, D, E, F, 7, 9 PAGE
DATA
1-2-1.
Initialization of A, D Page Data
1.
Initializing A, D Page Data
Note:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, D page data
2) Video system adjustments
3) LCD system adjustments
4) System control system adjustments
Adjsuting page
A
Adjsuting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 73
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
4
03
06
3
4
00
2D
4
4
01
2D
Press PAUSE button.
5
4
02
Check the data changes to “01”.
6
Perform “Modification of
A, D page Data”.
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of A, D Page Data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
5-9
DSC-P71/P71M
1-2-2.
Initialization of B, E, F, 7, 9 Page Data
1.
Initializing B, E, F, 7, 9 Page Data
Note:
If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Camera system adjustments
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
6
03
06
3
6
00
2D
4
6
01
2D
Press PAUSE button.
5
6
02
Check the data changes to “01”.
6
Perform “Modification of B,
E, F, 7, 9 page Data”.
2.
Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
5-10
DSC-P71/P71M
Address
Initial value
Remark
3E
FF
Flange back adj.
3F to 51
Fixed data-1 (Initialized data)
52
00
53
00
Flange back adj.
54 to 5D
Fixed data-1 (Initialized data)
5E
00
5F
00
60
00
61
00
F No. compensation
62
00
63
00
64
00
65
30
66
FE
Light value adj.
67
6D
68 to 6D
Fixed data-1 (Initialized data)
6E
00
Mixed color calcel adj.
6F
00
70
32
71
B2
72
23
73
64
74
32
AWB 3200K standard data input
75
6C
76
23
77
88
78 to 87
Fixed data-1 (Initialized data)
88
20
89
F5
8A
33
8B
14
8C
20
AWB 5800K standard data input
8D
E2
8E
33
8F
89
90 to 9F
Fixed data-1 (Initialized data)
A0
29
A1
D8
A2
6D
AWB 5800K standard data input
A3
08
A4
03
A5
E9
A6
63
A7
83
Color reproduction adj.
A8
D5
A9
FE
AA
73
5. F Page Table
Note 1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data. (Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
FF
11
FF
12
FF
13
FF
14
FF
AF Illumination check.
15
FF
16
FF
17
FF
18
00
19
00
1A
50
1B
00
1C
11
1D
B1
1E
09
1F
0F
20
00
21
00
22
00
23
00
24
20
25
20
26
35
27
44
28
0A
29
00
Flange back adj.
2A
00
2B
00
2C
00
2D
00
2E
00
2F
00
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
5-11
DSC-P71/P71M
Address
Initial value
Remark
AB
45
AC
63
AD
83
Color reproduction adj.
AE
03
AF
E9
B0
00
AWB 3200K standard data input
B1
00
AWB 5800K standard data input
B2
00
AWB 3200K standard data input
B3
00
AWB 5800K standard data input
B4
00
AWB 3200K standard data input
B5
Fixed data-1 (Initialized data)
B6
28
Strobe white balance adj.
B7
70
B8
0C
B9
C1
BA
0C
BB
C1
BC
00
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
00
C4
00
C5
00
C6
00
Mechanical shutter adj.
C7
33
C8
33
C9
33
CA
33
CB
33
CC
8A
CD
98
CE
90
CF
8A
D0
8A
D1
00
D2
00
D3
00
D4
00
D5
00
D6
00
Mechanical shutter adj.
D7
14
D8 to DA
Fixed data-1 (Initialized data)
DB
00
DC
00
Strobe white balance adj.
DD
00
Address
Initial value
Remark
DE
00
DF
00
E0
00
E1
00
E2
00
E3
00
E4
00
E5
00
E6
00
Strobe white balance adj.
E7
00
E8
00
E9
00
EA
00
EB
00
EC
00
ED
00
EE
00
EF
00
F0 to FF
Fixed data-1 (Initialized data)
6.
7 Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
7.
9 Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
Page of 127
Display

Click on the first or last page to see other DSC-P71 / DSC-P71M (serv.man2) service manuals if exist.