DOWNLOAD Sony DSC-P71 / DSC-P71M (serv.man2) Service Manual ↓ Size: 6.79 MB | Pages: 127 in PDF or view online for FREE

Model
DSC-P71 DSC-P71M (serv.man2)
Pages
127
Size
6.79 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-p71-dsc-p71m-sm2.pdf
Date

Sony DSC-P71 / DSC-P71M (serv.man2) Service Manual ▷ View online

5-24
DSC-P71/P71M
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
91
00
4
6
B6
00
5
Release the data setting
performed at step 2.
(Refer to page 5-13)
6
Remove the C14 filter on the
lens.
12. Auto White Balance 5800K Check 1
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Video terminal of
Page: 1
VIDEO OUT jack
(75 
Ω terminated)
Specified Value
Y level data: 20 to C0
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
Perform “Picture Frame
setting”.
(Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
04
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to
“01”.
11
6
01
00
Press PAUSE button.
12
6
16
04
13
6
B6
03
14
6
37
0E
15
6
01
C1
Press PAUSE button.
16
6
02
Check the data changes to
“01”.
17
0
03
33
18
1
Check that the Y level data
satisfied the specified value.
19
Perform “ Auto White
Balance 5800K check 2”.
5-25
DSC-P71/P71M
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
16
00
3
6
37
00
4
6
2C
00
5
6
91
00
6
0
03
00
7
Release the data setting
performed at step 3. (Refer to
page 5-13)
8
Remove the C14 filter on the
lens.
13. Auto White Balance 5800K Check 2
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at TELE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
VIDEO OUT jack
(Note 3)
(75 
Ω terminated)
Specified Value
R ratio: 28F8 to 2A38
B ratio: 6068 to 61A8
Note 1:
Perform this check after “Auto White Balance 5800K
Check 1” without a break.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
“Auto White Balance 5800K
Check 1” is complete.
2
Place the C14 filter on the
lens.
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
4
Perform “Picture Frame
setting”.
(Refer to page 5-14)
5
6
2C
01
6
6
90
00
7
6
91
04
8
6
92
00
9
6
93
00
10
6
01
79
Press PAUSE button.
11
6
07
Check the data changes to
“01”.
12
6
01
00
Press PAUSE button.
13
6
01
3F
Press PAUSE button.
14
6
02
Check the data changes to
“01”.
15
0
03
04
16
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
17
0
03
05
18
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
5-26
DSC-P71/P71M
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Fig. 5-1-16
14. Color Reproduction Adjustment
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Video terminal of VIDEO OUT
jack (75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
A4 to AF
Specified Value
All color luminance points
should settle within each color
reproduction frame.
Menu setting:
1)
VIDEO OUT of SET UP menu
................................
NTSC (NTSC mode)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Color Reproduction Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
Setting”.
(Refer to page 5-14)
3
6
01
AB
Press PAUSE button.
4
6
01
A9
Press PAUSE button.
(Note 3)
5
6
02
Check the data changes to
“01”.
6
Check the each color
luminance point is in each
color reproduction frame.
Note 3:
The adjustment data will be automatically input to page:
F, address: A4 to AF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
5-27
DSC-P71/P71M
15. CCD White Defect Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The“CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
E
64
Note down the data.
3
E
64
1E
Press PAUSE button.
4
E
69
Note down the data.
5
E
69
0A
Press PAUSE button.
6
6
01
8B
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
9
6
01
00
Press PAUSE button.
10
E
64
0F
Press PAUSE button.
11
E
69
60
Press PAUSE button.
12
6
01
87
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
6
55
Check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
E
64
Set data noted down at step
2, and press PAUSE button.
3
E
69
Set data noted down at step
4, and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 5-13)
Page of 127
Display

Click on the first or last page to see other DSC-P71 / DSC-P71M (serv.man2) service manuals if exist.