5-16
DSC-P71/P71M
2.
Flange Back Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
(Using the flange back adjustment chart and
Subject More than 500 m Away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
2-1. Flange Back Adjustment (1)
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
 Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 52, 53
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
6
01
13
Press PAUSE button.
3
6
01
15
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
F
3E
Check the data.
00: Normal
01 to FF: Defective
6
F
24
Check the data.
0A to 7F: Normal
00 to 09, 80 to FF: Defective
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
3
Perform “Flange Back
Adjustment (2)”.
2-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Mode
CAMERA
Subject
Subject more than 500 m away
(Subject with clear contrast such
as buildings, etc.)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
18 to 3E, 52, 53
Adjusting method:
Order Page Address Data
Procedure
1
Set the zoom lens to the
TELE end and expose a
subject that is more than 500
m away. (Note 1)
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
3
6
01
13
Press PAUSE button.
4
Place ND filter on the lens so
that the optimum image is
obtain.
5
6
01
29
Press PAUSE button.
(Note 2)
6
6
02
Check the data changes to
“01”.
7
F
3E
Check the data.
00: Normal
01 to FF: Defective
8
F
24
Check the data.
0A to 7F: Normal
00 to 09, 80 to FF: Defective
Note 1:
Subject with clear contrast such as building, etc.
Nearby subjects less than 500 m away should not be in
the screen.
Note 2:
The adjustment data will be automatically input to page:
F, address: 18 to 3E, 52 and 53.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-13)
3
Perform “Flange Back
Check”.
5-17
DSC-P71/P71M
3.
Flange Back Check
Mode
CAMERA
Subject
Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
2
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
4
B
3D
Note down the data.
5
B
3D
50
Press PAUSE button.
6
Shoot the Siemens star with
the zoom TELE end.
7
Turn on the auto focus.
8
Check that the lens is
focused.
9
6
2C
01
10
While observe the TV
monitor, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
B
3D
Set data noted down at step
4, and press PAUSE button.
3
Release the data setting
performed at step 3.
(Refer to page 5-13)
5-18
DSC-P71/P71M
4.
F No. Compensation
RadarW
RadarW
RadarW
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
5E to 64
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
01
BB
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 5E to 64.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
5.
Mechanical Shutter Adjustment
RadarW
RadarW
RadarW
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
B8 to D7
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
01
AD
Press PAUSE button.
(Note 2)
4
6
02
Check the data changes to
“01”.
5
6
AB
Check the data is “00”.
Note 2:
The adjustment data will be automatically input to page:
F, address: B8 to D7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-13)
5-19
DSC-P71/P71M
6.
Light Value  Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 1 (Note
2) and page: F, address: 65
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
65 to 67
Specified Value
AE level 1: 0FE0 to 1020
AE level 2: 29 to 3C
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
6
01
0D
Press PAUSE button.
(Note 4)
4
6
02
Check the data changes to
“01”.
5
0
03
06
6
1
Check that the displayed data
(Note 2) satisfies the AE
level 1 specified value.
7
F
65
Check that the displayed data
satisfies the AE level 2
specified value.
Note 3:
The adjustment data will be automatically input to page:
F, address: 65 to 67.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
Release the data setting
performed at step 1.
(Refer to page 5-13)
7.
Mixed Color Cancel Adjustment
RadarW
RadarW
RadarW
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
6E and 6F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
2
Perform “Picture Frame
setting”.
(Refer to page 5-14)
3
7
22
Note down the data.
4
7
22
00
Press PAUSE button.
5
6
01
D7
Press PAUSE button.
6
6
01
D5
Press PAUSE button.
(Note 2)
7
6
02
Check the data changes to
“01”.
Note 2:
The adjustment data will be automatically input to page:
F, address: 6E and 6F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
22
Set the data noted down at
step 3, and press PAUSE
button.
3
Release the data setting
performed at step 1.
(Refer to page 5-13)
Page of 127