STR-ZA1000ES/ZA2000ES/ZA3000ES
29
HISTORY  MODE
The state that the set is used is memorized.
Note: Even if “MEMORY CLEAR MODE” is performed, the backup data 
of “HISTORY MODE” is not cleared.
 
  Initialize by performing “SHIPMENT MODE”.
Procedure:
1.  While pressing the [SPEAKERS] and [DISPLAY] buttons, 
press the [
?/1
] button to turn on the power and “HISTORY” is 
displayed.
2.  Each time the [
V] or [v] buttons is pressed, the item is switched 
in order as follows.
Protector genaration total 
count
Operating time until generating 
first time protector (active 
standby is contained)
Main on time until generating 
first time protector
Factor of generating first time 
protector
Sound field in first time 
protector
Function in first time protector
Input mode in first time 
protector
Input under lock in first time 
protector
Stream under input in first time 
protector
Channel information in first 
time protector
State of headphone in first 
time protector
Volume in first time 
protector
Muting in first time protector
EQ setting value in first time 
protector (front bass)
EQ setting value in first time 
protector (front treble)
EQ setting value in first time 
protector (center bass)
EQ setting value in first time 
protector (center treble)
EQ setting value in first time 
protector (surround bass)
EQ setting value in first time 
protector (surround treble)
EQ setting value in first time 
protector (front high bass)
EQ setting value in first time 
protector (front high treble)
Level collection value each c
hannel in first time protector
(front L/front R)
Level collection value each 
channel in first time protector
(center/subwoofer)
Level collection value each 
channel in first time protector
(surround L/surround R)
Level collection value each 
channel in first time protector
(surround back L/
surround back R)
Level collection value each 
channel in first time protector
(front high L/front high R)
Temperature status
Total operation time after the 
shipment
Main zone power on time after 
the shipment
Number of times of the power 
on after the shipment
Releasing method:
Press the [
?/1
] button to turn off the main power.
STR-ZA1000ES/ZA2000ES/ZA3000ES
30
SOFTWARE  VERSION  MODE
The software version is displayed.
Procedure:
1.  Press the [
?/1
] button to turn off the main power.
2.  Press three buttons of the [PING], [A.F.D.] and [DISPLAY] si-
multaneously.
3.  The system software version appears.
 
(Displayed characters/values in the following fi gure are ex-
ample)
Releasing method:
Press the [
?/1
] button to turn off the main power.
PROTECTOR  AUTO  OFF  MODE
The auto off function after protection generating can be disabled.
Procedure:
1.  While pressing the [SPEAKERS] and [AMP MENU] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “PROTEVER” appears and the auto off function 
after protection generating is disabled.
Releasing method:
Press the [
?/1
] button to turn off the main power.
SHIPMENT  MODE
Initialize backup of EEPROM and network and return to state of 
the shipment.
Procedure:
1.  While pressing the [AMP MENU] and [ENTER] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “MEMORY CLEARING” appears and return to 
state of the shipment.
3.  When done, the message “MEMORY CLEARED!” appears  
and turn off the main power.
FACTORY  PRESET  MODE
The specifi c preset values are set.
Procedure:
1.  While pressing the [ZONE CONTROL] and [ENTER] but-
tons, press the [
?/1
] button to turn on the main power.
2.  The message “FACTORY” appears and specifi c preset values 
are set.
KEY  CHECK  TEST  MODE
Each buttons can be checked.
Procedure:
1.  While pressing the [SPEAKERS] and the [TONE−] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “REST 41” appears.
 
Every pressing of any button other than the [
?/1
] counts down 
the buttons.
 
(The buttons which are already counted once are not counted 
again)
3.  When all buttons are pressed “REST 00” appears.
Releasing method:
Pull out the power cord, or do not perform operation for 10 sec-
onds.
FLUORESCENT  PATTERN  CHECK  MODE
All fl uorescent segments are tested. When this test is activated, all 
segments turn on at the same time, then each segment turns on one 
after another.
Procedure:
1.  While pressing the [SPEAKERS] and the [TONE+] buttons, 
press the [
?/1
] button to turn on the main power.
2.  All segments turn on.
IN-CEILING
BT
DSEE
3.  Each time the [DISPLAY] button is pressed, the screen display 
is changed in order as follows.
All segments turn on
Test pattern 1
Test pattern 2
All segments turn off
IN-CEILING
BT
DSEE
IN-CEILING
BT
DSEE
Releasing method:
Press the [
?/1
] button to turn off the main power.
STR-ZA1000ES/ZA2000ES/ZA3000ES
31
SPECIAL  MODE
Various version displays of system, test, etc. can be performed.
Setting method:
1.  Press the [
?/1
] button to turn on the main power.
2.  While pressing the [DISPLAY] button, press the [A.F.D.], [MOVIE], [MULTI ST.] button in order, the message “SPECIAL MENU 
ON” appears.
3.  Press the [
V] or [v] button, the message “<<< SPECIAL  >>>” appears.
4.  Press the [ENTER] button, the “SPECIAL MENU” is appears.
5.  Each time the [
V] or [v] buttons is pressed, the item is switched in the order of the following table.
 
Some items can change the content. Display the cursor by pressing the [
b
] button, and change the content by pressing the [
V] or [v]. 
buttons, and fi x the content by pressing the [
B
] button when you want to change the content of the item.
Releasing method:
To release from this mode, while pressing the [DISPLAY] button, press the [A.F.D.], [MOVIE], [MULTI ST.] button in order again, the 
message “SPECIAL MENU OFF” appears, and this mode is released.
Display of special mode:
Items
Display
Remark
Model setting (display)
MODEL    XX UCA
XX: Model
System version
SYSTEM    VX.XXX
X.XXX: System software version
Main version
MAIN      VX.XX
X.XX: System controller software version
Video version
VIDEO     VX.XX
X.XX: Video system controller software version
ADV version
ADV       VX.XX
X.XX: Video processor software version
DSP SFLASH1 version
DSP S.FLASH VX.XX
X.XX: DSP serial fl ash software version
Network version
NETWORK    VX.XX
XXXX: Network system controller software version
DSP debug mode menu
<DSP DEBUG MENU>
Not used for the servicing.
Line check for update
LC FOR UPDATE >>
When [b] button is pressed, the message “CHECK START ?” 
is appears. When the [ENTER] button is pressed, the check of 
whether the path used for software update has connected is 
started.
When the checking results are OK, “UPDATE CHECK OK” is 
appears.
When the checking results are NG, “UPDATE CHECK NG” is 
appears.
HDCP key read mode
HDCP KEY    XXX
Not used for the servicing.
MIC check
SPK OUT  XXXXXX
XXXXXX: Output setting from the speaker
SOURCE: normal mode
MIC: mode that output audio to the speaker from microphone 
input
ARC check
ARC CHECK   XXX
XXX: “ON” or “OFF”
SPDIF signal reception on/off switched.
Zone A/D D/A check
ZONE ADDA  XXX
Not used for the servicing.
Hub test mode
HUB TEST  XXXXX
Not used for the servicing.
DCAC  MIC  TEST  MODE
The auto calibration microphone input can be outputted from the 
speaker.
Note: It is necessary to connect speakers to this unit.
Procedure:
1.  While pressing the [OPTIONS] and [TONE MODE] buttons, 
press the [
?/1
] button to turn on the main power.
2.  The message “MIC” appears.
3.  Check that sound which is inputted from microphone is out-
putted from the speaker.
Releasing method:
Press the [
?/1
] button to turn off the main power.
– Continued on next page –
STR-ZA1000ES/ZA2000ES/ZA3000ES
32
Items
Display
Remark
USB test mode
USB TEST XXXXXX
Display the cursor by pressing the [b] button, and select the 
“RUN” by pressing the [V] or [v] buttons.
When USB memory (FAT16 or FAT32 formatted) is inserted to 
the front USB connector of this unit and the [ENTER] button is 
pressed, reading and writing operate experimentally and the 
check of whether the front USB connector functions is started.
When the checking results are OK, “OK” is appears.
When the checking results are NG, “NG” is appears.
SRAM check
NET SRAM CHECK>>
When [b] button is pressed, the message “CHECK START ?” 
is appears. When the [ENTER] button is pressed, the check of 
whether the path used for software update has connected is 
started.
When the checking results are OK, “SRAM CHECK   OK” is 
appears.
When the checking results are NG, “SRAM CHECK   NG” is 
appears.
FL font check
FL FONT  0x**=X
**: 20 to FE, X: character
FL all light check
(All segments turn on)
Each time [DISPLAY] button to change as follows all segments 
on t test pattern 1 t test pattern 2 t all segments off t all  
segments on
FL duty check
FL DUTY    XXX%
Not used for the servicing.
EEPROM R/W check
EEPROM CHECK  >>
Not used for the servicing.
EEPROM super reset
EEPROM RESET  >>
Not used for the servicing.
Note: Never execute this mode, because deleting the important unit’s 
peculiar information including MAC address etc.
When EEPROM initialization is required, perform the “SHIP-
MENT MODE” on page 30
Auto standby debug menu
<AUTO.STBY DEBUG>
Not used for the servicing.
Protector debug mode
PROTECT DEBG.XXX
Not used for the servicing.
VACS control
VACS CTRL   XXX
Not used for the servicing.
VACS setting menu
<VACS SETTING  >
Not used for the servicing.
Pass through auto debug mode
P.THRU AT. DEBUG
Not used for the servicing.
DSP swap mode
DSP SWAP MODE
Not used for the servicing.
Fan control
FAN CTRL   XXXX
Not used for the servicing.
Page of 126