MX-M350/M450 N/U  SIMULATION  9 - 33
Operation/Procedure
1) Open the paper feed tray 2 paper feed guide to the max. width
position.
2) Select MAX POSITION with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [SYSTEM SETTINGS] key.
5) Open the paper feed tray 3 paper feed guide to the min. width
position.
6) Select MIN POSITION with 10-key.
7) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
The operating conditions of sensors and detectors are displayed.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Open the document cover and select NO ORIGINAL with 10-
key without placing any document on the document table.
2) Press [START] key.
The sensor level is set without document on the document
table.
3) Place an A3 document on the document table, and select A3
ORIGINAL with 10-key.
4) Press [START] key.
The sensor level is set when detection the document.
If the above procedures are not completed normally, "ERROR" is
displayed. If completed normally, "COMPLETE" is displayed.
Operation/Procedure
The detection output level (A/D value) of the document sensors
(PD1 - PD7) is displayed in real time.
The value in [ ] on the side of each sensor name indicates the
threshold value.
The light receiving value (A/D value) and the threshold value (A/D
value) of PD1 - PD7 are in the range of 1 - 255. The default of
threshold value is 128.
40-12
Purpose
Adjustment/Setup
Function
(Purpose)
Used to adjust the multi-purpose tray width 
detection level.
Section
Paper feed
Item
Operation
Press [START] key.
Press [SYSTEM SETTINGS] key.
41
41-1
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The operation of 
the document size sensor can be monitored with 
the LCD display.)
Section
Other
Item
Operation
OCSW
Document cover 
status
Open: Normal display
Close: Highlighted
PD1 - 7
Document detection 
sensor status
No document: Normal display
Document present: Highlighted
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT. SELECT 1-2, AND PRESS
START.
1.MAX. POSITION
2.MIN. POSITION
1
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MAX. POSITION ··· COMPLETE (or "ERROR")
Press [SYSTEM SETTINGS] key.
Select 1 and press [START] key. 
SIMULATION 40-12
MULTI PURPOSE TRAY ADJUSTMENT.
MIN. POSITION ··· COMPLETE (or "ERROR")
SIMULATION 41-1
PD SENSOR CHECK..
OCSW  
PD1
  
PD2
  
PD3
  PD4  PD5  PD6  PD7
41-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the document size sensor sensing 
level.
Section
Other
Item
Operation
Select 2 and press [START] key. 
(Error)
Press [SYSTEM SETTINGS] 
key.
41-3
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the document size 
sensor and the related circuit. (The document size 
sensor output level can be monitored with the LCD 
display.)
Section
Other
Item
Operation
OCSW
Original cover status
Open: Normal display
Close: Highlighted
PD1 - 7
PD sensor detection level The value in [ ] indicates the 
adjustment threshold value (SIM41-2 adjustment 
value).
SIMULATION 41-2
PD SENSOR ADJUSTMENT. SELECT1-2, AND PRESS START.
(PLEASE OPEN THE ORIGINAL COVER.) 
1. NO ORIGINAL
2. A3 ORIGINAL
1
SIMULATION 41-2
Press [SYSTEM SETTINGS] key. 
Select 1 and 
press [START] key. 
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
A3 ORIGINAL ··· INCOMPLETE
SIMULATION 41-2
PD SENSOR ADJUSTMENT.
NO ORIGINAL ··· COMPLETE
A3 ORIGINAL ··· COMPLETE (or "ERROR at 
PD1 PD2
...")
MX-M350/M450 N/U  SIMULATION  9 - 34
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
Operation/Procedure
When bit =1, correction is made.
Operation/Procedure
1) Select the number corresponding to the setting mode with 10-
key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
*1: Only when this value is 0, control is made with the actual mea-
surement value of the process thermistor (temperature/humid-
ity). When it is not 0, control is made with the forcible setting
value.
43
43-1
Purpose
Setting
Function
(Purpose)
Used to set the fusing temperature in each 
operation mode.
Section
Fixing (Fusing)
Item
Operation
Item
Default
1
INSIDE NORMAL
Heater inside/normal
190
2
OUTSIDE NORMAL
Heater outside/normal
190
3
INSIDE PREHEAT
Heater inside/preheat
150
4
OUTSIDE PREHEAT
Heater outside/preheat
150
Press [START] key.
Press [SYSTEM SETTINGS] key.
44
44-1
Purpose
Setting
Function
(Purpose)
Used to set enable/disable of correction 
operations in the image forming (process) section.
Section
Image process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Operation
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
0
0
0
0
0
0
Vg4
Vb4
Ld4
Vbr
Vg3
Vb3
Ld3
Vb1
Vb2
Ld2
Vg2
Ld1
Vg1
SIMULATION 41-3
PD SENSOR DATA DISPLAY.
OCSW
PD1[128]: 200     PD2[128]: 200
PD3[128]:  50     PD4[128]:  52
PD5[128]:  51     PD6[128]:  50
PD7[128]:  52
SIMULATION 43-1
1
FUSER TEMPERATURE SET. SELECT 1-4, AND PRESS START.
1. INSIDE NORMAL 
190
2. OUTSIDE NORMAL 
190
3. INSIDE PREHEAT 
150
4. OUTSIDE PREHEAT 
150
SIMULATION 43-1
FUSER TEMPERATURE SET. INPUT VALUE, AND PRESS START.
1. INSIDE NORMAL
190
44-4
Purpose
Setup
Function
(Purpose)
Used to set the target image (reference) density 
level in the developing bias voltage correction.
Section
Process 
(Photoconductor/Developing/Transfer/Cleaning)
Item
Data
Item
1
TEMP. AREA *1
Process environment temperature 
forcible setting value 
(0 - 13 /normal: 0)
2
HUMIDITY AREA *1
Process environment humidity 
forcible setting value 
(0 - 14 /normal: 0)
3
S_WT
Vb rising correction standby time
(0 - 180 sec/default: 90)
4
Vb1
Vb correction amount (first rotation) 
(0 - 150V/default: 50)
5
Vb2
Vb correction amount (second 
rotation) (0-50V/default: 15)
Press [START] key.
Press [SYSTEM SETTINGS] key.
SIMULATION 44-1
PROCESS CORRECTION VALUE SETTING. INPUT VALUE 0-255
AND PRESS START.
BIT0:Vg1, BIT1:Ld1, BIT2:Vg2,  BIT3:Ld2
BIT4:Vb1, Vb2
BIT5:Vg3, Vb3, Ld3
BIT6:Vbr   
BIT7:Vg4, Vb4, Ld4
111
SIMULATION 44-4
3
PROCESS CONTROL VALUE SETTING. SELECT 1-5 AND PRESS
START.
1.TEMP. AREA     
0
2.HUMIDITY AREA  
0
3.S_WT   
90
4.Vb1    
50
5.Vb2    
15
SIMULATION 44-4
PROCESS CONTROL VALUE SETTING. INPUT VALUE, AND PRESS
START.
3.S_WT
 90
MX-M350/M450 N/U  SIMULATION  9 - 35
Operation/Procedure
Operation/Procedure
The output levels of the temperature thermistor and the humidity
thermistor in the developing unit are displayed.
Operation/Procedure
Operation/Procedure
1) Select the number corresponding to the copy mode to be
adjusted with 10-key. (Select one of 3 - 6.)
2) Press [START] key.
3) Enter the copy density level with 10-key.
4) Press P key or [START] key.
The adjustment value is set.
When [START] key is pressed, copying is performed and the
adjustment value is simultaneously set.
Check the density of the printed copy image.
NOTE: When the copy image density is adjusted with this simula-
tion, the copy image densities of all the copy modes are
changed to the copy image density level set with this simu-
lation.
That is, the copy image density of each copy mode set with
SIM 46-9, 10, 11 is changed to the copy image density
level adjusted with this simulation.
To select paper (paper feed tray), perform the following proce-
dures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed
tray selection mode.)
44-9
Purpose
Adjustment/Setup/Operation data output/Check 
(Display/Print)
Function
(Purpose)
Used to check the data related to the image 
forming section correction (process correction) 
result (corrected main charger grid voltage, the 
developing bias voltage, and the laser power 
voltage in each print mode). (This simulation 
allows to check that correction is performed 
normally or not.)
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Item
Data
Operation data (Machine condition)
DRUM ROTATION TIME
Drum rotation time (sec)
DEVE ROTATION TIME
Developer rotation time (sec)
Vg1 - Vg4
Grid voltage correction value
Vb1 - Vb4
Developing bias correction value
Ld1 - Ld4
Laser power correction value
DESTINATION 1
Machine CRUM destination (1-9)
DESTINATION 2
CRUM destination (1-9)
44-14
Purpose
Adjustment/Setup/Operation data output/Check 
(Display)
Function
(Purpose)
Used to check the output level of the temperature 
sensor and the humidity sensor.
Section
Image process (Photoconductor/Developing)
Item
Operation
TH-DV
Developing temperature thermistor
0 - 255
HUS-DV
Developing humidity thermistor
0 - 255
44-16
Purpose
Adjustment/Setup/Operation data output/Check 
(Display)
Function
(Purpose)
Used to check the toner concentration control 
data.
Section
Image process (Developing)
Item
Operation
HUMIDITY AREA
Humidity area
INT HUMIDITY AREA
Humidity area in development 
adjustment
TEMPERATURE AREA
Temperature area
INT TEMPERATURE AREA
Temperature area in 
development adjustment
TARGET LEVEL
Toner control reference value
SIMULATION 44-9
PROCESS CONTROL DATA DISPLAY.
DRUM ROTATION TIME:
01234567
(sec)
DEVE ROTATION TIME:
01234567
(sec)
Vg1:
30
(V) Vg2:
30
(V) Vg3:
30
(V) Vg4:
30
(V)
Vb1:
30
(V) Vb2:
10
(V) Vb3:
30
(V) Vb4:
10
(V)
Ld1: 
0
    Ld2: 
0
    Ld3: 
0
    Ld4: 
0
DESTINATION1:
1
DESTINATION2:
1
SIMULATION 44-14
SENSOR DATA DISPLAY MONITOR.
TH-DV:      
255
HUS-DV:     
255
DEV REF
Development adjustment 
registration value
HUM
Humidity correction value
(TARGET)
Target value of humidity 
correction
TMP
Temperature correction value
(TARGET)
Target value of temperature 
correction
LIFE
Environment correction value
(TARGET)
Target value of environment 
correction
46
46-2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density in all the copy 
modes (Auto, Text, Text/Photo, and Photo mode).
Item
Picture quality
Density
Item
Set 
range
Default
0
TRAY SELECT
Paper feed tray 
selection
1
COPY START
Copy START (Default)
2
EXP LEVEL
Exposure level selection
3
AE 3.0
AE mode
0 - 99
50
4
CH 3.0
Text mode 3.0
5
MIX 3.0
Text/Photo mode 3.0
6
PHOTO 3.0
Photo mode 3.0
Normal display
NOW COPYING.
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
SIMULATION 44-16
TONER CONTROL STANDARD LEVEL DISPLAY.
HUMIDITY AREA: 
11
INT HUMIDITY AREA: 
7
TEMPERATURE AREA: 
6
INT TEMPERATURE AREA: 
6
TARGET LEVEL=DEV REF+HUM(TARGET)+TMP(TARGET)+LIFE(TARGET)
        
133
 = 
118
   + 
10
(
10
)    +  
0
(
0
)     +   
5
(
5
)
MX-M350/M450 N/U  SIMULATION  9 - 36
3) Enter the number corresponding to the paper feed tray to be
used with 10-key.
4) Press [START] key. (The paper feed tray is selected.)
NOTE: When [P] key is pressed after entering an adjustment value
in this simulation, the adjustment value is set. When
START key is pressed, the adjustment value is set and
copying is performed.
Operation/Procedure
1) Select the number corresponding to the copy density adjust-
ment level with 10-key. (Select one of 3 - 11.) 
2) Press [START] key. 
3) Enter the copy density level with 10-key.
4) Press [P] key or [START] key. 
The adjustment value is set. 
When [START] key is pressed, copying is perfumed and the
adjustment value is set simultaneously.
Check the density of printed copy image.
To select paper (paper feed tray), perform the following proce-
dures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed
tray selection mode.)
3) Enter the number corresponding to the paper feed tray to be
used with 10-key.
4) Press [START] key. (The paper feed tray is selected.)
NOTE: When [P] key is pressed after entering an adjustment value
in this simulation, the adjustment value is set. When
START key is pressed, the adjustment value is set and
copying is performed.
1
TRAY1
TRAY1
2
TRAY2
TRAY2
3
TRAY3
TRAY3
4
TRAY4
TRAY4
5
BPT
Manual feed
Select 2, and press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
SIMULATION 46-2
Select other then 0 - 2, and 
press [START] key.
Press [SYSTEM SETTINGS] key. 
SIMULATION 46-2
EXP. LEVEL SETUP (2). INPUT VALUE 0-99, AND PRESS START.
3. AE 3.0
Press [START] key.
SIMULATION 46-2
EXP. LEVEL SETUP (2). NOW COPYING.
50
Press [SYSTEM SETTINGS] key, 
or terminate copying.
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 1-5, AND PRESS START.
(FEED TRAY)
  1. TRAY1  2. TRAY2  3. TRAY3  4. TRAY4
  5. BPT
Press [START] key, or 
press [SYSTEM SETTINGS] key.
1
Select 0, and 
press [START] key.
1
Select 1, 
and press 
[START] key. 
EXP. LEVEL SETUP (2). SELECT 0-6, AND PRESS START.
0. TRAY SELECT 
1
  1. COPY START
2. EXP LEVEL 
1
3. AE 3.0 
50
  4. CH 3.0 
50
5. MIX 3.0 
50
  6. PHOTO 3.0 
50
SIMULATION 46-2
EXP. LEVEL SETUP (2). SELECT 3-6, AND PRESS START.
(EXP. LEVEL SELECT)
  3. AE 3.0    4. CH 3.0
  5. MIX 3.0   6. PHOTO 3.0
1
46-9
Purpose
Adjustment
Function
(Purpose)
Used to adjust the print density for each density
level (display value) in the copy mode (binary -
Text mode). An optional print density can be set
for each density level (display value).
Item
Picture quality
Density
Item
Set 
range
Default
0
TRAY SELECT
Paper feed tray selection
1
COPY START
Copy START (Default)
2
EXP LEVEL
Exposure level selection
3
1.0
Exposure level 1.0
0 - 99
50
4
1.5
Exposure level 1.5
5
2.0
Exposure level 2.0
6
2.5
Exposure level 2.5
7
3.0
Exposure level 3.0
8
3.5
Exposure level 3.5
9
4.0
Exposure level 4.0
10 4.5
Exposure level 4.5
11 5.0
Exposure level 5.0
Normal display
NOW COPYING.
ERROR display
Door open
DOOR OPEN.
Jam
JAM
Paper empty
PAPER EMPTY.
1
TRAY1
TRAY1
2
TRAY2
TRAY2
3
TRAY3
TRAY3
4
TRAY4
TRAY4
5
BPT
Manual feed
Page of 87
Display

Click on the first or last page to see other MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) service manuals if exist.