Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) Service Manual ▷ View online
MX-M350/M450 N/U SIMULATION 9 - 13
*1: Displayed when OPTION of multi-purpose only.
*2: Displayed when manual feed OPTION is added.
Operation/Procedure
1) Select the number corresponding to the target of operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1 operates.
Press [SYSTEM SETTINGS] key to stop the operation.
Operation/Procedure
1) Select the number corresponding to the operating condition of
aging with 10-key.
The combined mode of 0 - 6 mode and 10, 20, or 30 mode can
be set.
be set.
In that case, the number corresponding to one of 0 - 6 mode
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
and the number corresponding to one of 10, 10, and 30 mode
are added and the sum number is entered.
2) Press [START] key.
The condition selected in procedure 1) is set.
The setting of this simulation is kept valid until the power is turned
off.
off.
18*1
MCLUM
MP tray lift-up motor signal
19*2
MPFS
Manual paper feed solenoid signal
20*2
MPFC
Manual paper feed clutch signal
21*2
MSS
Manual paper feed gate solenoid
Press [START] key, and the
operation is started.
operation is started.
Press [SYSTEM SETTINGS] key, and the
operation is stopped immediately or after
repeating the operation several times.
operation is stopped immediately or after
repeating the operation several times.
6-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of each fan motor
and its control circuit.
and its control circuit.
Section
Other
Item
Operation
1
Fan motor high speed
2
Fan motor low speed
3
Cooling fan motor (Controller/HDD)
Press [START] key, and the operation
is started.
is started.
Press [SYSTEM SETTINGS] key, and
the operation is stopped.
the operation is stopped.
SIMULATION 6-1
FEED OUTPUT CHECK. SELECT 1-22, AND PRESS START.
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20. MPFC 21.MSS 22.MSWS
2
SIMULATION 6-1
FEED OUTPUT CHECK. EXECUTING....
1.MSWPR 2.HLPR 3.DCPR 4.MM 5.DM 6.DSB_FW
7.DSB_RV 8.CPFC 9.RRC 10.TRC 11.FGS_FIN
12.LUM 13.TRC_DSK 14.PSPS
15.MCM 16.MCPCL 17.MCFCL 18.MCLUM
19.MPFS 20.MPFC 21.MSS 22.MSWS
2
SIMULATION 6-2
FAN MOTOR CHECK. SELECT 1-3, AND PRESS START.
1.FMHi
2.FMLo
3.CFM-ICU/HDD
2
SIMULATION 6-2
FAN MOTOR CHECK..
2.FMLo
2
7
7-1
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the operating conditions of aging.
Section
Item
Operation
0
NO MISS FEED DETECTION No jam detection
1
AGING
Aging mode
2
AGING/NO MISS FEED
DETECTION.
DETECTION.
No jam detection, aging
mode
mode
3
AGING/NO MISS FEED
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
DETECTION/NO WARM UP/
NO TEMPERATURE
CONTROL.
No jam detection/ no warm-
up/ no fusing temperature
control, aging mode
up/ no fusing temperature
control, aging mode
4
NO WARM UP.
No warm-up
5
AGING/INTERVAL.
Intermittent aging mode
6
AGING/INTERVAL/NO MISS
FEED DETECTION.
FEED DETECTION.
No jam detection
intermittent aging mode
intermittent aging mode
+10 NO PROCESS UNIT CHECK. Above +10: No process unit
(including the developing
unit) detection
unit) detection
+20 NO SHADING.
Above +20: No shading
+30 NO PROCESS UNIT CHECK/
NO SHADING.
Above +30: No process unit
detection /no shading
detection /no shading
Press [START] key to start registration and operation.
The operation mode is kept until the power is turned off or setting is made again.
The operation mode is kept until the power is turned off or setting is made again.
SIMULATION 7-1
AGING TEST SETTING. SELECT 0-36, AND PRESS START.
0.NO MISS FEED DETECTION
1.AGING
2.AGING/NO MISS FEED DETECTION.
3.AGING/NO MISS FEED DETECTION/
NO WARM UP/NO TEMPERATURE CONTROL.
4.NO WARM UP.
5.AGING/INTERVAL.
6.AGING/INTERVAL/NO MISS FEED DETECTION.
+10:NO PROCESS UNIT CHECK.
+20:NO SHADING.
+30:NO PROCESS UNIT CHECK/NO SHADING.
2
MX-M350/M450 N/U SIMULATION 9 - 14
Operation/Procedure
1) Enter the intermittent aging cycle (unit: sec) with 10-key.
2) Press [START] key.
The time entered in procedure 1) is set.
∗
Set range of interval time: 1 - 999 (sec)
Set the intermittent aging mode cycle of 7-1 with 10-key. (Unit:
sec)
sec)
Operation/Procedure
1) Select the number corresponding to the warm-up time display
YES/NO.
2) Press [START] key, and the number selected in procedure 1)
is set.
∗
The setting of this simulation is kept valid until the power is
turned off.
turned off.
The warm-up time is displayed in the unit of second.
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The developing bias output voltage adjustment and output check
can be made in each print mode.)
can be made in each print mode.)
7-6
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the intermittent aging cycle.
Section
Item
Operation
7-8
Purpose
Setting
Function
(Purpose)
(Purpose)
Used to set the warm-up time display YES/NO.
Item
Operation
Warm-up is completed.
Press [SYSTEM SETTINGS] key.
SIMULATION 7-6
INTERVAL AGING CYCLE SETUP. INPUT TIME AND PRESS START.
(1-999, UNIT: sec)
10
SIMULATION 7-8
WARM UP TIME DISPLAY.
ARE YOU SURE?
1. YES
2. NO
1
Press [START] key,
and time count is started.
and time count is started.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARMING UP,PLEASE WAIT.
(UNIT:sec)
30
Press [SYSTEM SETTINGS] key,
and time count is stopped.
and time count is stopped.
SIMULATION 7-8
WARM UP TIME DISPLAY. WARM UP COMPLETED.
(UNIT:sec)
60
8
8-1
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operations of the
developing voltage of each color and the control
circuit.
developing voltage of each color and the control
circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Transfer/Cleaning)
Item
Set
range
Default
MX-
M350
MX-
M450
1
AUTO
Auto mode
0 - 745
455
485
2
CHARACTER Text mode
485
485
3
MIX
Text/Photo mode
4
PHOTO
Photo mode
5
PRINTER
Printer mode
6
FAX
FAX mode
7
PLUS
Reverse developing
bias voltage
bias voltage
0 - 255
150
150
Press [START] key.
Press [SYSTEM SETTINGS] key.
Press [START] key.
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
Or after 30sec output.
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO
485
2.CHARACTER
485
3.MIX
485
4.PHOTO
485
5.PRINTER
485
6.FAX
485
7.PLUS
150
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-745)
485
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
485
MX-M350/M450 N/U SIMULATION 9 - 15
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the
set value is outputted for 30sec.)
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The main charger grid output voltage adjustment and output
check can be made in each print mode.)
check can be made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in each print mode.)
made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with
10-key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the
set value is outputted for 30sec.)
set value is outputted for 30sec.)
Press [SYSTEM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be
made in the transfer belt cleaning mode.)
made in the transfer belt cleaning mode.)
8-2
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the
main charger grid voltage in each printer mode
and the control circuit.
main charger grid voltage in each printer mode
and the control circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Transfer/Cleaning)
Item
Set
range
Default
MX-
M350
MX-
M450
1 AUTO
Auto mode
200 - 900
615
645
2 CHARACTER Text mode
645
645
3 MIX
Text/Photo mode
4 PHOTO
Photo mode
5 PRINTER
Printer mode
6 FAX
FAX mode
Press [START] key.
Press [SYSTEM SETTINGS] key.
Press [START] key.
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
Or after 30sec output.
8-6
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the
transfer voltage and the control circuit.
transfer voltage and the control circuit.
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)/Transfer
Transfer/Cleaning)/Transfer
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO
645
2.CHARACTER
645
3.MIX
645
4.PHOTO
645
5.PRINTER
645
6.FAX
645
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-900)
645
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
645
Item
Set
range
Default
MX-
M350
MX-
M450
1
FRONT
Long side print mode
0 - 620
220
267
2
BACK
Back side print mode
267
310
Press [START] key.
Press [SYSTEM SETTINGS] key.
Press [START] key.
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
Or after 30sec output.
8-17
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the
transfer voltage and the related circuit. (Transfer
belt cleaning mode)
transfer voltage and the related circuit. (Transfer
belt cleaning mode)
Section
Image process (Photoconductor/Developing/
Transfer/Cleaning)
Transfer/Cleaning)
Item
Operation
Item
Set
range
Default
MX-
M350
MX-
M450
1
SHF FRONT
AC component
0 - 240
120
160
2
SHV BACK
AC component
0 - 240
120
160
3
THV-
DC component
0 - 1250
780
780
SIMULATION 8-6
1
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT
267
2.BACK
310
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-620)
267
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
267
MX-M350/M450 N/U SIMULATION 9 - 16
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated.
Press [SYSTEM SETTINGS] key to stop the operation.
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
played.
The active sensors and detectors are highlighted.
Operation/Procedure
1) Select the number corresponding to the target of the operation
check with 10-key.
2) Press [START] key.
The load selected in procedure 1) is operated for 10sec.
Press [SYSTEM SETTINGS] key to stop the operation.
NOTE: Never execute this simulation with toner in the toner hop-
per.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
If executed, excessive toner will enter the developing sec-
tion. Be sure to remove the toner motor from the toner hop-
per before execution.
Press [START] key.
Press [SYSTEM SETTINGS] key.
Press [START] key.
Press [SYSTEM SETTINGS] key.
Or after 30sec output.
Or after 30sec output.
9
9-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the load
(clutch/solenoid) in the duplex section and the
control circuit.
(clutch/solenoid) in the duplex section and the
control circuit.
Section
Duplex
Item
Operation
1
ADMEN1
ADU motor 1 control signal
2
ADMEN2
ADU motor 2 control signal
3
DGS
ADU gate solenoid
Press [START] key.
Press [SYSTEM SETTINGS] key to
stop the operations.
stop the operations.
SIMULATION 8-17
1
TRANSFER ROLLER SETTING. SELECT 1-3, AND PRESS START.
1.SHV FRONT
160
2.SHV BACK
160
3.THV-
780
SIMULATION 8-17
TRANSFER ROLLER SETTING. INPUT VALUE, AND PRESS START.
1.FRONT (0-240)
160
SIMULATION 8-17
TRANSFER ROLLER SETTING. EXECUTING···.
1.FRONT(0-240)
160
SIMULATION 9-1
ADU OUTPUT CHECK. SELECT 1-3, AND PRESS START.
1.ADMEN1
2.ADMEN2
3.DGS
1
SIMULATION 9-1
ADU OUTPUT CHECK. EXECUTING···.
1.ADMEN1
2.ADMEN2
3.DGS
1
9-2
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the sensors and
detectors in the duplex section and its control
circuit.
detectors in the duplex section and its control
circuit.
Section
Duplex
Item
Operation
ADUSET
ADU installation detection
DSW_D
ADU cabinet open detection
AINPD
ADU paper entry detection
APOD
ADU paper exit detection
APPD1
ADU paper detection 1
APPD2
ADU paper detection 2
10
10-1
Purpose
Operation test/Check
Function
(Purpose)
(Purpose)
Used to check the operations of the toner motor
and the related circuit.
and the related circuit.
Section
Process (Developing)
Item
Operation
1
Toner motor rotation start
2
Cancel (The display returns to the main code entry menu.)
Press [START] key.
Press [SYSTEM SETTINGS] key to
stop the operations. Or after 10sec.
stop the operations. Or after 10sec.
SIMULATION 9-2
ADU SENSOR CHECK.
ADUSET
DSW_D
AINPD APOD APPD1 APPD2
SIMULATION 10-1
TONER MOTOR ACTIVATION.
ARE YOU SURE?
1.YES
2.NO
2
SIMULATION 10-1
TONER MOTOR ACTIVATION. EXECUTING···.
1
Click on the first or last page to see other MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) service manuals if exist.