DOWNLOAD Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) Service Manual ↓ Size: 1.03 MB | Pages: 87 in PDF or view online for FREE

Model
MX-M350N MX-M350U MX-M450N MX-M450U (serv.man10)
Pages
87
Size
1.03 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Simulations
File
mx-m350n-mx-m350u-mx-m450n-mx-m450u-sm10.pdf
Date

Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) Service Manual ▷ View online

MX-M350/M450 N/U  SIMULATION  9 - 45
Operation/Procedure
(Toner save operation YES/NO setting in the auto mode)
1) Select "1. AE MODE" with 1-key.
2) Press [START] key.
3) Select the number corresponding to the operation specifica-
tions with 10-key.
4) Press [START] key.
When [START] key is pressed, the adjustment value is set.
(Operation setting in the auto copy mode)
1) Select the number corresponding to the mode with 10-key.
(Select one of 2 - 4.)
2) Press [START] key.
3) Select the number corresponding to the operation mode with
10-key.
4) Press [START] key.
Select 2, and 
press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
46-19
Purpose
Adjustment
Function
(Purpose)
Used to set the auto mode operation specifications 
in each mode (copy, scan, FAX).
Item
Picture quality
Density
64
1
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 0-18, AND PRESS START.
0.TRAY SELECT  
1
   1.PRINT START     2.EXP LEVEL  
1
3.OC_AE       
64
   4.OC_CHARA        5.OC_MIX    
64
6.OC_PHOTO    
64
7.SPF1_AE     
64
   8.SPF1_CHARA  
64
  9.SPF1_MIX  
64
10.SPF1_PHOTO 
64
11.SPF2_AE    
64
   12.SPF2_CHARA 
64
  13.SPF2_MIX 
64
14.SPF2_PHOTO 
64
15.CIS_AE     
64
   16.CIS_CHARA  
64
  17.CIS_MIX  
64
18.CIS_PHOTO  
64
SIMULATION 46-18
GAMMA SETUP. INPUT VALUE 0-127, AND PRESS START.
3.OC_AE
SIMULATION 46-18
GAMMA SETUP. NOW PRINTING.
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 1-5, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT
Select other than 0 - 2, 
and press [START] key.
Press [SYSTEM SETTINGS] key.
Press [START] key.
Press [SYSTEM SETTINGS] key, 
or terminate copying.
Select 1, 
and press 
[START] key. 
Select 0, and press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
1
SIMULATION 46-18
GAMMA SETUP(COPIER). SELECT 3-14, AND PRESS
START.
(EXP.LEVEL SELECT)
3.AUTO     4.1.0     5.2.0
6.3.0      7.4.0     8.5.0
9.AUTO(H)    10.1.0(H)     11.2.0(H)
12.3.0(H)    13.4.0(H)     14.5.0(H)
1
AE MODE
AE mode
2
AE STOP MODE (COPIER)
AE fixed mode (Copier)
3
AE STOP MODE (SCANNER)
AE fixed mode (Scanner)
4
AE STOP MODE (FAX)
AE fixed mode (FAX)
Mode
Set 
value
Item
Default
AE 
mode
1
Image quality priority mode 
(Normal mode)
Gamma is sharp to provide
high contrast images.
2
2
Toner consumption priority mode
Gamma is mild to provide low
contrast images.
AE 
fixed 
mode
0
AE fixed OFF
1 (COPIER)
(SCANNER/
FAX)
1
AE fixed ON
AE fixed OFF: The automatic density (exposure) control is per-
formed in real time. (The density level is changed
in real time according to the document pattern.)
AE fixed ON:
The density at the lead edge of the document is
scanned, and the overall density (exposure) level is
determined according to the scanned density level.
(Overall density level fixed)
Select 2, 3, or 4 and 
press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
2
Select 1, and 
press [START] key. 
Press [SYSTEM SETTINGS] key.
SIMULATION 46-19
EXP.MODE SETUP. SELECT 1-4, AND PRESS START.
1.AE MODE         
2
2.AE STOP MODE(COPIER) 
1
3.AE STOP MODE(SCANNER)
0
4.AE STOP MODE(FAX)    
0
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 1-2, AND PRESS START.
1.AE MODE
1
SIMULATION 46-19
EXP.MODE SETUP. INPUT VALUE 0-1, AND PRESS START.
2.AE STOP MODE(COPIER)
MX-M350/M450 N/U  SIMULATION  9 - 46
Operation/Procedure
(Adjustment mode selection)
1) Select the number corresponding to the copy mode to be
adjusted with 10-key.
SPF odd pixel (Front surface copy), SPF even pixel (Front sur-
face copy), SPF (Back surface copy) (Select one of 3 - 5.)
2) Press [SATART] key.
(Copy density level adjustment)
1) Enter the density correction value with 10-key.
2) Press [P] key or [START] key.
(Copy condition setting in this simulation)
To select paper (paper feed tray), perform the following proce-
dures.
1) Enter 0 with 10-key. 
2) Press [START] key. (The mode is changed to the paper feed
tray selection mode.)
3) Enter the number corresponding to the paper feed tray to be
used with 10-key.
4) Press [START] key. (The paper feed tray is selected.)
NOTE: When [P] key is pressed after entering an adjustment value
in this simulation, the adjustment value is set. When
START key is pressed, the adjustment value is set and
copying is performed.
• "Set value - 128" is added to the shading adjustment value (SIM
46-17).
Operation/Procedure
1) Select "SCANNER EXP. LEVEL" with 10-key.
2) Press [START] key.
3) Enter the image density adjustment value.
4) Press [P] key or [START] key.
NOTE: When this simulation is performed to adjust the scan image
densities, all the image densities in all the scan modes are
changed to the image density level set with this simulation.
That is, the image densities set with SIM 46-22, 23, 24, 25,
and 45 are changed to the image density level set with this
simulation.
NOTE: Only the set value is changed and no printing is performed.
46-20
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy density correction in the 
SPF copy mode for the document table copy 
mode. The adjustment is made so that the copy 
density becomes the same as that of the 
document table copy mode. 
Section
SPF
Item
Picture quality
Density
Item
Content
Set 
range
Default
0 TRAY SELECT Paper feed tray selection
1: TRAY1
2: TRAY2
3: TRAY3
4: TRAY4
5: Manual feed
1 PRINT START
Print start (Default)
2 EXP LEVEL
Exposure level selection
3: Exposure level 1.0
4: Exposure level 1.5
5: Exposure level 2.0
6: Exposure level 2.5
7: Exposure level 3.0
8: Exposure level 3.5
9: Exposure level 4.0
10: Exposure level 4.5
11: Exposure level 5.0
3 SPF (ODD)
SPF (front) (odd pixel)
0 - 255
128
4 SPF (EVEN)
SPF (front) (even pixel)
5 DSPF
DSPF (Back surface) 
46-21
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner exposure level in all 
the scanner modes.
Item
Picture quality
Density
Item
Set 
range
Default
0 SCANNER EXP. LEVEL Image density level 0 - 99
50
SIMULATION 46-20
1
Press [SYSTEM SETTINGS] key. 
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT. INPUT VALUE 0-255, AND PRESS
START.
3.SPF(ODD)
128
Press [START] key. 
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT.  NOW PRINTING.
Press [SYSTEM SETTINGS] key, 
or terminate copying.
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT. SELECT 1-5, AND PRESS START.
(FEED TRAY)
  1.TRAY1  2.TRAY2  3.TRAY3  4.TRAY4
  5.BPT
Press [START] key or 
press [SYSTEM SETTINGS] key.
1
Select 0, and 
press [START] key.
Select 1, 
and press 
[START] key. 
SIMULATION 46-20
OC/SPF EXP. ADJUSTMENT. SELECT 3-8, AND PRESS START.
(EXP. LEVEL SELECT)
3.1.0     4.1.5     5.2.0
6.2.5     7.3.0     8.3.5
9.4.0     10.4.5    11.5.0
1
Press [START] key or 
press [SYSTEM SETTINGS] key.
Select 2, and 
press [START] key.
OC/SPF EXP. ADJUSTMENT. SELECT 0-5, AND PRESS START.
0.TRAY SELECT  
1
  1.PRINT START
2.EXP LEVEL    
1
3.SPF(ODD)   
128
4.SPF(EVEN)  
128
5.DSPF       
128
Select other than 0 - 2, and press [START] key.
MX-M350/M450 N/U  SIMULATION  9 - 47
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 5.)
Normal mode (Image density adjustment level)
Auto mode
2) Press [START] key.
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
NOTE: Only the set value is changed and no printing is performed.
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
Normal mode (Image density adjustment level)
Normal mode (Image density adjustment level) (Half-tone
mode)
Auto mode
Auto mode (Half-tone mode)
2) Press [START] key. 
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
NOTE: Only the set value is changed and no printing is performed.
Press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
46-22
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner exposure level in the 
normal text mode.
Item
Picture quality
Density
Item
Set 
range
Default
0
AUTO
Auto
0 - 99
50
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
Select other than 0 - 5, and 
press [START] key.
Press [START] key, or press 
[SYSTEM SETTINGS] key.
0
SIMULATION 46-21
EXP.LEVEL SETUP SCANNER(AUTO SET), PRESS START.
0.SCANNER EXP.LEVEL 
50
50
SIMULATION 46-21
EXP.LEVEL SETUP SCANNER(AUTO SET), INPUT VALUE 0-99,
AND PRESS START.
0.SCANNER EXP.LEVEL
1
SIMULATION 46-22
EXP.LEVEL SETUP SCANNER(NORMAL). SELECT 0-5, AND PRESS
START.
0.AUTO 
50
 1.1.0 
50
    2.2.0 
50
3.3.0 
50
  4.4.0 
50
    5.5.0 
50
50
SIMULATION 46-22
EXP.LEVEL SETUP SCANNER(NORMAL), INPUT VALUE 0-99, AND
PRESS START.
0.AUTO
46-23
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner exposure level in the 
fine text mode.
Item
Picture quality
Density
Item
Set 
range
Default
0
AUTO
Auto
0 - 99
50
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
6
AUTO (H)
Auto (Half-tone)
7
1.0 (H)
Exposure level 1 (Half-tone)
8
2.0 (H)
Exposure level 2 (Half-tone)
9
3.0 (H)
Exposure level 3 (Half-tone)
10
4.0 (H)
Exposure level 4 (Half-tone)
11
5.0 (H)
Exposure level 5 (Half-tone)
Select other than 0 - 11, and 
press [START] key. 
Press [START] key, or 
press [SYSTEM SETTINGS] key.
1
SIMULATION 46-23
EXP.LEVEL SETUP SCANNER(FINE). SELECT 0-11,AND PRESS
START.
0.AUTO 
50
  1.1.0 
50   
  2.2.0 
50
3.3.0 
50
   4.4.0 
50
     5.5.0 
50
6.AUTO(H) 
50
   7.1.0(H) 
50
    8.2.0(H) 
50
9.3.0(H) 
50
   10.4.0(H) 
50
   11.5.0(H) 
50
 
50
SIMULATION 46-23
EXP.LEVEL SETUP SCANNER(FINE). INPUT VALUE 0-99, AND
PRESS START.
0.AUTO
MX-M350/M450 N/U  SIMULATION  9 - 48
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
Normal mode (Image density adjustment level)
Normal mode (Image density adjustment level) (Half-tone
mode)
Auto mode
Auto mode (Half-tone mode)
2) Press [START] key.
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
NOTE: Only the set value is changed and no printing is performed.
Operation/Procedure
1) Select the number corresponding to one of the following
adjustment items with 10-key. (Select one of 0 - 11.)
Normal mode (Image density adjustment level)
Normal mode (Image density adjustment level) (Half-tone
mode)
Auto mode
Auto mode (Half-tone mode)
2) Press [START] key.
3) Enter the image density adjustment value with 10-key.
4) Press [START] key or press [P] key.
The adjustment value is set.
NOTE: Only the set value is changed and no printing is performed.
46-24
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner exposure level in the 
super fine text mode.
Item
Picture quality
Density
Item
Set 
range
Default
0
AUTO
Auto
0 - 99
50
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
6
AUTO (H)
Auto (Half-tone)
7
1.0 (H)
Exposure level 1 (Half-tone)
8
2.0 (H)
Exposure level 2 (Half-tone)
9
3.0 (H)
Exposure level 3 (Half-tone)
10 4.0 (H)
Exposure level 4 (Half-tone)
11 5.0 (H)
Exposure level 5 (Half-tone)
Select other than 0 - 11, and 
press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
1
SIMULATION 46-24
EXP.LEVEL SETUP SCANNER(SUPER FINE). SELECT 0-11,AND
PRESS START.
0.AUTO 
50
  1.1.0 
50   
  2.2.0 
50
3.3.0 
50
     4.4.0 
50
       5.5.0 
50
6.AUTO(H) 
50
 7.1.0(H) 
50
    8.2.0(H) 
50
9.3.0(H) 
50
 10.4.0(H) 
50
   11.5.0(H) 
50
 
50
SIMULATION 46-24
EXP.LEVEL SETUP SCANNER(SUPER FINE). INPUT VALUE 0-99,
AND PRESS START.
0.AUTO
46-25
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner exposure level in the 
ultra fine text mode. 
Item
Picture quality
Density
Item
Set 
range
Default
0
AUTO
Auto
0 - 99
50
1
1.0
Exposure level 1
2
2.0
Exposure level 2
3
3.0
Exposure level 3
4
4.0
Exposure level 4
5
5.0
Exposure level 5
6
AUTO (H)
Auto (Half-tone)
7
1.0 (H)
Exposure level 1 (Half-tone)
8
2.0 (H)
Exposure level 2 (Half-tone)
9
3.0 (H)
Exposure level 3 (Half-tone)
10 4.0 (H)
Exposure level 4 (Half-tone)
11 5.0 (H)
Exposure level 5 (Half-tone)
Select other than 0 - 11, and 
press [START] key.
Press [START] key, or 
press [SYSTEM SETTINGS] key.
SIMULATION 46-25
EXP.LEVEL SETUP SCANNER(ULTRA FINE). SELECT 0-11,AND
PRESS START.
0.AUTO 
50
  1.1.0 
50   
  2.2.0 
50
3.3.0 
50
   4.4.0 
50
     5.5.0 
50
6.AUTO(H) 
50
   7.1.0(H) 
50
    8.2.0(H) 
50
9.3.0(H) 
50
   10.4.0(H) 
50
    11.5.0(H) 
50
 
50
SIMULATION 46-25
EXP.LEVEL SETUP SCANNER(ULTRA FINE). INPUT VALUE 0-99,
AND PRESS START.
0.AUTO
Page of 87
Display

Click on the first or last page to see other MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man10) service manuals if exist.