MX-M356NV  MX-FN26 N (FINISHER)  7 – 5
21) Fix the connection plate from the front with the M3 screw which
are packed with the finisher.
22) Install the finisher connection cabinet from the left. And, install
the finisher front cabinet lower with screw. 
23) Fix the FIN transmission harness with the bundled hexagonal
screws. 
24) Fix the clamp of the FIN transmission harness to the frame and
fix the earth cable with the bundled screw.
25) Remove the dummy connector and connect the harness of the
FIN transmission harness. Then, connect the other harness to
the PWB.
MX-M356NV  MX-FN26 N (FINISHER)  7 – 6
26) Install the rear cabinet to the original position, and fix it with
screw.
27) Install the left cabinet to the original position.
28) Cut the part shown in the figure for the connector from the fin-
isher.
29) Install the front cabinet left to the original position.
30) Install the finisher front cover from the left side by sliding, and
close the finisher front cover and the machine front cover.
31) Install the paper holding arm.
32) Connect the machine connection connector.
33) Attach the staple position label to the document feed unit.
MX-M356NV  MX-TR17 N (EXIT TRAY UNIT)  8 – 1
MX-M356NV
Service Manual
 
[8] MX-TR17 N (EXIT TRAY UNIT)
1.  Parts included
2.  Installation
NOTE: Turn off the main switch of the machine and then remove
the power plug of the machine from the outlet.
1)
Remove two EPE cushions.
2)
Remove the mylar. (Other than the North America)
3)
Remove five screws and remove the rear cabinet.
4)
Remove screws and remove the right cabinet middle.
5)
Insert the harness of the right paper exit unit to the hole of the
second paper exit.
NOTE: Wire the harness to the upper of the rib. 
If wiring it to the under of the rib, the harness may
come into contact with the gear.
6)
Insert the pawl of the right paper exit unit to the oval hole of the
frame of the main unit.
Insert the positioning boss of the main unit to the round hole in
lower side.
7)
When tightening the screw, tighten in the sequence of (A), (B),
(C) and (D).
Harness cover OP
Screw (M3 x 4)
Paper exit
right cover
Right paper
exit actuator
Screw (M4 x 10)
Screw (M3 x 8)
Right delivery harness (Not use)
MX-M356NV  MX-TR17 N (EXIT TRAY UNIT)  8 – 2
8)
Fix the harness to the wire saddles and connect the connector
of the harness to the PCU PWB (CN 1). 
9)
Install the paper exit right cover sub and tightening the screw.
10) Install the right paper exit actuator and the paper holding arm.
A
B
C
D
Insert the actuator to 
the holes of righjt paper 
exit part (R/F side).  
Paper holing arm
Right paper exit 
actuator
Right paper exit paper 
full detection point
Paper insert 
direction