DOWNLOAD Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ↓ Size: 20.02 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M264N MX-M264NR MX-M264NV MX-M264U MX-M314N MX-M314NR MX-M314NV MX-M314U MX-M354N MX-M354NR MX-M354U (serv.man7)
Pages
127
Size
20.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised April 2016).
File
mx-m264n-mx-m264nr-mx-m264nv-mx-m264u-mx-m314n-mx-.pdf
Date

Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ▷ View online

MX-M264U  SIMULATION  6 – 20
 
23
 
23-2
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to output the trouble history list of
paper jam and misfeed. (If the number of
troubles of misfeed is considerably great,
the judgment is made that repair is
required.)
Section
Operation/Procedure
Press [EXECUTE] key to execute print.
The trouble history of paper jams and misfeed is printed.
 
23-80
Purpose
Operation test/check
Function (Purpose)
Used to check the operation of paper feed
and paper transport in the paper feed sec-
tion and the paper transport section. Used
to output the list of the operation status of
the sensor and the detectors in the paper
feed section and the paper transport sec-
tion.
Section
Paper feed, Paper transport
Operation/Procedure
When [EXECUTE] key is pressed, the timing list of paper feed and
paper transport is outputted.
Used to print the operations timing list of the sensors and detectors
in the paper feed and transport section.
The timing list of paper feed and paper transport operations of the
latest job (copy or print) on the final paper is printed.
Since the paper feed and paper transport routes differ depending
on the used paper feed tray and the print operation mode, the sen-
sor and the detectors and the operation timing also differ.
*1: The value without unit on the left side of each item on the list
has no relation to the operation timing. It is not used in the market.
 
24
 
24-1
Purpose
Data clear
Function (Purpose)
Used to clear the jam counter, and the trou-
ble counter. (After completion of mainte-
nance, clear the counters.)
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-2
Purpose
Data clear
Function (Purpose)
Used to clear the number of use (the num-
ber of prints) of each paper feed section.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-3
Purpose
Data clear
Function (Purpose)
Used to clear the finisher, RSPF, and the
scan (reading) unit counter.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
SECTION
Operation content (Trigger name - Detection operation 
or load operation name)
STANDARD
Reference value (ms)
CURRENT (*1)
Operation timing (ms) of the latest job on the final 
paper
PREVIOUS (*1)
Operation timing (ms) of the second latest job on the 
final paper
MAXIMUM (*1)
Max. operation timing (ms) of all the jobs
MINIMUM (*1)
Min. operation timing (ms) of all the jobs
MACHINE
Machine JAM counter
SPF
RSPF JAM counter
TROUBLE
Trouble counter
TRAY1
Tray 1 paper feed counter
TRAY2
Tray 2 paper feed counter
TRAY3
Tray 3 paper feed counter
TRAY4
Tray 4 paper feed counter
MFT TOTAL
Manual paper feed counter (Total)
MFT HEAVY
Manual paper feed counter (Heavy paper)
MFT OHP
Manual paper feed counter (OHP)
MFT ENV
Manual paper feed counter (Envelope)
ADU
ADU paper feed counter
SPF
RSPF document feed counter 
(No. of discharged sheets)
SCAN
Scan counter
STAPLER
Staple counter
STAMP
Stamp counter
COVER
Document cover open/close counter
HP_ON
Number of scanner HP detection
OC LAMP TIME
Total lighting time of the scanner lamp
MX-M264U  SIMULATION  6 – 21
 
24-4
Purpose
Data clear
Function (Purpose)
Used to clear the maintenance counter, the
printer counters of the transport unit and
the fusing unit. (After completion of mainte-
nance, clear the counters.)
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-5
Purpose
Data clear
Function (Purpose)
Used to clear the developer counter. (After
replacement of developer, clear the coun-
ter.)
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
NOTE: The "Developer cartridge life meter" counter displayed in
SIM22-13 is not displayed in this simulation, but it is
cleared in conjunction with this simulation.
 
24-6
Purpose
Data clear
Function (Purpose)
Used to clear the copy counter.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-9
Purpose
Data clear
Function (Purpose)
Used clear the printer mode print counter
and the self print mode print counter.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-10
Purpose
Data clear
Function (Purpose)
Used to clear the FAX counter. 
(Only when FAX is installed)
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
Item/Display
Content
Maintenance
MAINTENANCE 
ALL
Maintenance counter (Total) (Counter)
Maintenance counter (Total) 
(Number of use days)
Fusing
FUSING 
ROLLER
Fusing roller (Counter)
Fusing roller (Number of use days)
Fusing roller 
(Accumulated number of rotations)
PRESS 
ROLLER
Pressure roller (Counter)
Pressure roller (Number of use days)
Pressure roller 
(Accumulated number of rotations)
Separation
SEPARATE 
PAWL
Separation pawl (Counter)
Separation pawl (Number of use days)
Separation pawl 
(Accumulated number of rotations)
CLEAN 
ROLLER
Cleaning roller (Counter)
Cleaning roller (Number of use days)
Cleaning roller 
(Accumulated number of rotations)
Transfer
TC ROLLER
Transfer roller (Counter)
Transfer roller (Number of use days)
Transfer roller 
(Accumulated number of rotations)
Drum
DRUM CTRG K
Drum cartridge (K) (Counter)
Drum cartridge (K) (Number of use 
days)
Drum cartridge (K) (Accumulated 
number of rotations)
Main 
charger
MAIN 
CHARGER K
Main charger (K) (Counter)
Main charger (K) (Number of use days)
Main charger (K) (Accumulated number 
of rotations)
Drum blade
DRUM BLADE 
K
Drum blade K (Counter)
Drum blade K (Number of use days)
Drum blade K (Accumulated number of 
rotations)
Other
OZONE FILTER
Ozone filter (Counter)
Ozone filter (Number of use days)
K
Developer cartridge print counter (K)
Accumulated number of rotations of the developer cartridge (K)
Number of day that used developer (Day) K
COPY BW
Copy counter (B/W)
PRINT BW
Print counter (B/W)
OTHER BW
Other counter (B/W)
FAX OUTPUT
FAX Print quantity counter
FAX SEND
FAX send counter
FAX RECEIVED
FAX receive counter
SEND IMAGES
FAX send quantity counter
SEND TIME
FAX send time
RECEIVED TIME
FAX receive time
MX-M264U  SIMULATION  6 – 22
 
24-12
Purpose
Data clear
Function (Purpose)
Used to clear the document filing counter
value.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-15
Purpose
Data clear
Function (Purpose)
Used to clear the counters related to the
scan mode and the image send.
Section
Operation/Procedure
1)
Select the item to be cleared with the touch panel key.
2)
Press [EXECUTE] key.
3)
Press [YES] key.
The target counter is cleared.
 
24-30
Purpose
Data clear
Function (Purpose)
Used to initialize the administrator (Admin)
password.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The administrator password is initialized.
 
24-31
Purpose
Data clear
Function (Purpose)
Used to initialize the service mode pass-
word.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
Used to initialize the service mode password.
 
24-35
Purpose
Data clear
Function (Purpose)
Used to clear the toner cartridge use status
data.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The toner cartridge use status data (SIM22-14) are cleared.
 
25
 
25-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the devel-
oping section.
Section
Process (Developing section)
Operation/Procedure
1)
Press [EXECUTE] key.
The developing motor and the OPC drum motor rotate for 3
minutes and the output level of the toner density sensor is dis-
played.
DOC FIL (BW)
Black-white document filing print counter
Division
Item/Display
Content
Network 
scanner
NET SCN ORG_B/W
Network scanner document read 
quantity counter (B/W scan job)
NET SCN ORG_CL
Network scanner document read 
quantity counter (COLOR scan job)
Internet 
Fax
INTERNET FAX 
OUTPUT
Number of internet FAX output
INTERNET FAX 
SEND OUTPUT
Number of internet FAX sending 
page
INTERNET FAX 
RECEIVE
Number of internet FAX receive
INTERNET FAX 
SEND
Number of internet FAX send
E-mail
MAIL COUNTER
Number of times of E-MAIL send
FTP
FTP COUNTER
Number of FTP send
Other
SMB SEND
Number of SMB send
USB CNT
Number of times of USB storage
TRIAL MODE_B&C
Trial mode counter (B/W & COLOR 
scan job)
SCAN TO HDD_B/W
SCAN TO HDD record quantity (B/W)
SCAN TO HDD_CL
SCAN TO HDD record quantity 
(COLOR)
Sensor name (Display)
Sensor name
TCS_K
Toner sensor output value (K)
MX-M264U  SIMULATION  6 – 23
 
25-2
Purpose
Setting
Function (Purpose)
Used to make the initial setting of toner
density when replacing developer. (Auto-
matic adjustment)
Section
Image process (Photoconductor/Develop-
ing)
Operation/Procedure
1)
Press [EXECUTE] key.
The developing motor rotates and the toner density sensor makes
sampling of the toner density, displaying the detected level.
After stopping the developing motor, it is set as the reference toner
density control level.
CAUTION: When the above operation is interrupted on the way, the
reference toner concentration level is not set. Also when
error code of EE-EL or EE-EU is displayed, the refer-
ence toner density level is not set normally.
CAUTION: Do not execute this simulation except when new devel-
oper is supplied. If it is executed in other cases, under-
toner or overtone may occur, causing a trouble.
Display during execution of the simulation
Error content
 
25-4
Purpose
Adjustment/Setting/Operation data check
Function (Purpose)
Used to display the operation data of the
toner correction quantity. (Not used in the
market.)
Section
Process
Operation/Procedure
The operation data of the toner supply quantity are displayed.
 
26
 
26-1
Purpose
Setting
Function (Purpose)
Used to set Yes/No of installation of the Job
separator.
Section
Paper exit
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
This setting is required to use the Job separator.
 
26-2
Purpose
Setting
Function (Purpose)
Used to set the paper size of the paper feed
tray. (When the paper size is changed, this
simulation must be executed to change the
paper size in software.)
Section
Paper feed
Operation/Procedure
Select a paper size and a weight system to be changed.
Item/Display
Content
Display 
range
Default 
value
AT DEVE ADJ
Automatic development 
adjustment value
1 - 255
128
Item/Display
Content
TCS
Toner sensor output value
Display
Error name
Error content
EE-EL
EL abnormality
The sensor output level is less than 78.
EE-EU
EU abnormality
The sensor output level exceeds 178. 
Item/Display
Content
Display 
range
TONER DEN_LT
Current toner density sensor output 
value (final value)
1 - 255
TONER DEN_ST
Current toner density reference 
value display (the value including all 
the correction values)
1 - 255
AUTO DEVE
Automatic development adjustment 
value
1 - 255
ALL
All correction reference value
1 - 255
LIFE
Life correction value
-128 - 127
ENV
Environment correction value
-128 - 127
DUPLEX
Duplex correction value
-128 - 127
PRINT RATE
Print ratio correction value
-128 - 127
AREA
Area correction value
-128 - 127
AUTO DEVE AREA
Area in the auto development 
adjustment
-128 - 127
CURRENT AREA
Current area
-128 - 127
Item/Display
Content
A
0
YES
Job separator provided
1
NO
Job separator not provided
Item
Setting value
Content
LEGAL SET
0
8.5 x 14
1
8.5 x 13.4
2
8.5 x 13.5
G/LBS SET
0
GRAM
1
LBS
Destination 
Setting value
LEGAL SET
G/LBS SET
U.S.A
8.5 x 14
LBS
CANADA
8.5 x 14
LBS
INCH
8.5 x 14
LBS
JAPAN
8.5 x 14
GRAM
AB_B
8.5 x 14
GRAM
EUROPE
8.5 x 14
GRAM
U.K.
8.5 x 14
GRAM
AUS.
8.5 x 14
GRAM
AB_A
8.5 x 14
GRAM
CHINA
8.5 x 14
GRAM
Page of 127
Display

Click on the first or last page to see other MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) service manuals if exist.