DOWNLOAD Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ↓ Size: 20.02 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M264N MX-M264NR MX-M264NV MX-M264U MX-M314N MX-M314NR MX-M314NV MX-M314U MX-M354N MX-M354NR MX-M354U (serv.man7)
Pages
127
Size
20.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised April 2016).
File
mx-m264n-mx-m264nr-mx-m264nv-mx-m264u-mx-m314n-mx-.pdf
Date

Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ▷ View online

MX-M264U  SIMULATION  6 – 36
Code descriptions
List of destination groups
31cpm machine
T
HI_WARMUP_TIME
R, S applying time (Timer from 
completion of Ready)
0  -  255
0
0
0
0
0
0
0
0
U
HI_WU_FM_ON_TMP
FM prior rotation start TH_US 
when Warm-Up at alpha degree C 
or above
0  -  220
0
0
0
0
0
0
0
0
V
HI_WU_END_TIME
Warm-Up completion time when 
Warm-Up at alpha degree C or 
above
0 - 60
18
18
18
18
18
18
18
18
W
HI_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or above
30 - 220
130
175
175
175
175
175
175
175
X
HI_WARMUP_BORDER
Threshold value alpha to which U - 
W is applied
1  -  119
60
60
60
60
60
60
60
60
Y
LO_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or below
70 - 220
130
175
175
175
175
175
175
175
Z
JOBEND_FUMON_TIME
After rotating time when a job is 
completed
0  -  60
0
0
0
0
0
0
0
0
AA
HI_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or above
70 - 220
130
175
175
175
175
175
175
175
AB
LO_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or below
70 - 220
130
175
175
175
175
175
175
175
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
Group
Destination
Group  A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
Ready standby TH_UM set value
70 - 220
185
185
185
185
190
190
190
190
B
HL_US READY
Ready standby TH_US set value
70 - 220
180
180
180
180
185
185
185
185
C
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM 
set value
70 - 220
185
195
190
195
195
200
195
200
D
HL_US PLAIN PAPER BW
Black-White plain paper TH_US 
set value
70 - 220
185
195
190
195
195
200
195
200
E
WARMUP FUMON HL_UM T
Fusing motor pre-rotation start 
TH_US set value
0  -  200
0
0
0
0
0
0
0
0
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation 
complete time
0  -  60
0
0
0
0
0
0
0
0
G
WARMUP END TIME
Warm-up complete time
0 - 20
18
18
18
18
18
18
18
18
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 220
200
200
200
200
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 220
200
200
200
200
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 220
190
190
195
195
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 220
190
190
195
195
L
HL_UM E-STAR
Preheating TH_UM set value
70 - 220
95
95
95
95
95
95
95
95
M
HL_US E-STAR
Preheating TH_US set value
70 - 220
95
95
95
95
95
95
95
95
N
HL_UM PRE-JOB
TH_UM set value when recovery 
from Warm-Up
70 - 220
130
180
180
180
190
190
190
190
O
HL_UM WARMUP_120L
TH_UM set value when Warm-Up 
at 120 degree C or below
70 - 220
130
180
180
180
190
190
190
190
P
HL_US WARMUP_120L
TH_US set value when Warm-Up 
at 120 degree C or below
70 - 220
130
180
180
180
190
190
190
190
MX-M264U  SIMULATION  6 – 37
Code descriptions
List of destination groups
35cpm machine
Q
LO_WARMUP_TIME
O, P applying time (Timer from 
completion of Ready)
0  -  255
0
0
0
0
0
0
0
0
R
HL_UM WARMUP_120H
TH_LM set value when Warm-Up 
at 120 degree C or above
70 - 220
130
180
180
180
190
190
190
190
S
HL_US WARMUP_120H
TH_US set value when Warm-Up 
at 120 degree C or above
70 - 220
130
180
180
180
190
190
190
190
T
HI_WARMUP_TIME
R, S applying time (Timer from 
completion of Ready)
0  -  255
0
0
0
0
0
0
0
0
U
HI_WU_FM_ON_TMP
FM prior rotation start TH_US 
when Warm-Up at alpha degree C 
or above
0  -  220
0
0
0
0
0
0
0
0
V
HI_WU_END_TIME
Warm-Up completion time when 
Warm-Up at alpha degree C or 
above
0 - 60
18
18
18
18
18
18
18
18
W
HI_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or above
30 - 220
130
180
180
180
190
190
190
190
X
HI_WARMUP_BORDER
Threshold value alpha to which U - 
W is applied
1  -  119
60
60
60
60
60
60
60
60
Y
LO_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or below
70 - 220
130
180
180
180
190
190
190
190
Z
JOBEND_FUMON_TIME
After rotating time when a job is 
completed
0  -  60
0
0
0
0
0
0
0
0
AA
HI_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or above
70 - 220
130
180
180
180
190
190
190
190
AB
LO_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or below
70 - 220
130
180
180
180
190
190
190
190
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
Group
Destination
Group  A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
Ready standby TH_UM set value
70 - 220
185
185
185
185
190
190
190
190
B
HL_US READY
Ready standby TH_US set value
70 - 220
180
180
180
180
185
185
185
185
C
HL_UM PLAIN PAPER BW
Black-White plain paper TH_UM 
set value
70 - 220
195
200
195
200
195
200
195
200
D
HL_US PLAIN PAPER BW
Black-White plain paper TH_US 
set value
70 - 220
195
200
195
200
195
200
195
200
E
WARMUP FUMON HL_UM T
Fusing motor pre-rotation start 
TH_US set value
0  -  200
0
0
0
0
0
0
0
0
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation 
complete time
0  -  60
0
0
0
0
0
0
0
0
G
WARMUP END TIME
Warm-up complete time
0 - 20
18
18
18
18
18
18
18
18
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 220
200
200
200
200
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 220
200
200
200
200
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 220
195
195
195
195
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 220
195
195
195
195
L
HL_UM E-STAR
Preheating TH_UM set value
70 - 220
95
95
95
95
95
95
95
95
M
HL_US E-STAR
Preheating TH_US set value
70 - 220
95
95
95
95
95
95
95
95
MX-M264U  SIMULATION  6 – 38
Code descriptions
List of destination groups
N
HL_UM PRE-JOB
TH_UM set value when recovery 
from Warm-Up
70 - 220
130
180
180
180
190
190
190
190
O
HL_UM WARMUP_120L
TH_UM set value when Warm-Up 
at 120 degree C or below
70 - 220
130
180
180
180
190
190
190
190
P
HL_US WARMUP_120L
TH_US set value when Warm-Up 
at 120 degree C or below
70 - 220
130
180
180
180
190
190
190
190
Q
LO_WARMUP_TIME
O, P applying time (Timer from 
completion of Ready)
0  -  255
0
0
0
0
0
0
0
0
R
HL_UM WARMUP_120H
TH_LM set value when Warm-Up 
at 120 degree C or above
70 - 220
130
180
180
180
190
190
190
190
S
HL_US WARMUP_120H
TH_US set value when Warm-Up 
at 120 degree C or above
70 - 220
130
180
180
180
190
190
190
190
T
HI_WARMUP_TIME
R, S applying time (Timer from 
completion of Ready)
0  -  255
0
0
0
0
0
0
0
0
U
HI_WU_FM_ON_TMP
FM prior rotation start TH_US 
when Warm-Up at alpha degree C 
or above
0  -  220
0
0
0
0
0
0
0
0
V
HI_WU_END_TIME
Warm-Up completion time when 
Warm-Up at alpha degree C or 
above
0 - 60
18
18
18
18
18
18
18
18
W
HI_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or above
30 - 220
130
180
180
180
190
190
190
190
X
HI_WARMUP_BORDER
Threshold value alpha to which U - 
W is applied
1  -  119
60
60
60
60
60
60
60
60
Y
LO_WU_JOB_SET_TMP 1
Job enable TH_UM temperature 1 
when Warm-Up at alpha degree C 
or below
70 - 220
130
180
180
180
190
190
190
190
Z
JOBEND_FUMON_TIME
After rotating time when a job is 
completed
0  -  60
0
0
0
0
0
0
0
0
AA
HI_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or above
70 - 220
130
180
180
180
190
190
190
190
AB
LO_WU_JOB_SET_TMP 2
Job enable TH_UM temperature 2 
when Warm-Up at alpha degree C 
or below
70 - 220
130
180
180
180
190
190
190
190
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
Group D
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
Group
Destination
Group  A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
MX-M264U  SIMULATION  6 – 39
 
43-4
Purpose
Setting
Function (Purpose)
Used to set the fusing temperature 2 in
each mode.
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
26cpm machine
Code descriptions
List of destination groups
31cpm machine
Item
Display
Content
Setting 
range
Default value (SW-A)
Default value (SW-B)
Group 
A
Group 
B
Group 
C
Group 
D
Group 
A
Group 
B
Group 
C
Group 
D
A
HL_UM PLAIN PAPER BW 
DUP
Black and white plain paper 
duplex TH_UM set value
70 - 220
175
175
185
185
175
175
185
185
B
HL_US PLAIN PAPER BW 
DUP
Black and white plain paper 
duplex TH_US set value
70 - 220
175
175
185
185
175
175
185
185
C
PLAIN PAPER BW DUP 
APP CNT
Black and white plain paper 
duplex applying number of sheets
0  -  255
0
0
0
0
0
0
0
0
D
HL_UM HEAVY PAPER BW 
DUP
Black and white heavy paper 
duplex TH_UM set value
70 - 220
175
175
185
185
175
175
185
185
E
HL_US HEAVY PAPER BW 
DUP
Black and white heavy paper 
duplex TH_US set value
70 - 220
175
175
185
185
175
175
185
185
F
HEAVY PAPER BW DUP 
APP CNT
Black and white heavy paper 
duplex applying number of sheets
0  -  255
0
0
0
0
0
0
0
0
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing 
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
Group
Destination
Group  A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
Item
Display
Content
Setting 
range
Default value (SW-A)
Default value (SW-B)
Group 
A
Group 
B
Group 
C
Group 
D
Group 
A
Group 
B
Group 
C
Group 
D
A
HL_UM PLAIN PAPER BW 
DUP
Black and white plain paper 
duplex TH_UM set value
70 - 220
185
190
195
195
185
190
195
195
B
HL_US PLAIN PAPER BW 
DUP
Black and white plain paper 
duplex TH_US set value
70 - 220
185
190
195
195
185
190
195
195
C
PLAIN PAPER BW DUP 
APP CNT
Black and white plain paper 
duplex applying number of sheets
0  -  255
0
0
0
0
0
0
0
0
D
HL_UM HEAVY PAPER BW 
DUP
Black and white heavy paper 
duplex TH_UM set value
70 - 220
185
190
195
195
185
190
195
195
E
HL_US HEAVY PAPER BW 
DUP
Black and white heavy paper 
duplex TH_US set value
70 - 220
185
190
195
195
185
190
195
195
F
HEAVY PAPER BW DUP 
APP CNT
Black and white heavy paper 
duplex applying number of sheets
0  -  255
0
0
0
0
0
0
0
0
Page of 127
Display