Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ▷ View online
MX-M264U SIMULATION 6 – 40
Code descriptions
List of destination groups
35cpm machine
Code descriptions
List of destination groups
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group
Destination
Group A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
Item
Display
Content
Setting
range
Default value (SW-A)
Default value (SW-B)
Group
A
Group
B
Group
C
Group
D
Group
A
Group
B
Group
C
Group
D
A
HL_UM PLAIN PAPER BW
DUP
DUP
Black and white plain paper
duplex TH_UM set value
duplex TH_UM set value
70 - 220
195
195
195
195
195
195
195
195
B
HL_US PLAIN PAPER BW
DUP
DUP
Black and white plain paper
duplex TH_US set value
duplex TH_US set value
70 - 220
195
195
195
195
195
195
195
195
C
PLAIN PAPER BW DUP
APP CNT
APP CNT
Black and white plain paper
duplex applying number of sheets
duplex applying number of sheets
0 - 255
0
0
0
0
0
0
0
0
D
HL_UM HEAVY PAPER BW
DUP
DUP
Black and white heavy paper
duplex TH_UM set value
duplex TH_UM set value
70 - 220
195
195
195
195
195
195
195
195
E
HL_US HEAVY PAPER BW
DUP
DUP
Black and white heavy paper
duplex TH_US set value
duplex TH_US set value
70 - 220
195
195
195
195
195
195
195
195
F
HEAVY PAPER BW DUP
APP CNT
APP CNT
Black and white heavy paper
duplex applying number of sheets
duplex applying number of sheets
0 - 255
0
0
0
0
0
0
0
0
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
SW-A
Setting value when plain paper is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when heavy paper is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
The set value displayed in this simulation differs depending on plain paper or heavy paper which is selected in the system setting/device setting/fusing
control setting.
(Example) When plain paper is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group
Destination
Group A
JAPAN
-
-
-
-
Group B
U. S. A
CANADA
INCH
-
-
Group C
AB_B
EUROPE
U. K
AUS.
AB_A
Group D
CHINA
-
-
-
-
MX-M264U SIMULATION 6 – 41
43-10
Purpose
Setting
Function (Purpose)
Used to set the postcard feed cycle
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key. (The set value is saved.)
43-20
Purpose
Function (Purpose)
Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
* WARMUP END TIME LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
* Items C/D: Correction of "-5" is made for item C and Item D in the case of B5 size
Item
Display
Content
Setting
range
Default
value
A
POSTCARD CYCLE
Postcard feed cycle
1 - 99
50
Item
Display
Content
Setting
range
Default
value
A
HL_UM READY LL
Correction value for TH_UM set value in ready standby under LL environment
1 - 99
55
B
HL_US READY LL
Correction value for TH_US set value in ready standby under LL environment
1 - 99
55
C
HL_UM PLAIN BW LL
Correction value for black and white plain paper TH_UM set value under LL environment
1 - 99
55
D
HL_US PLAIN BW LL
Correction value for black and white plain paper TH_US set value under LL environment
1 - 99
55
E
WARMUP FUMON HL_US T
LL
LL
Correction value for fusing motor previous rotation start TH_UM set value under LL environment
1 - 99
50
F
WARMUP FUMOFF LL
Fusing motor prior rotation completion time under LL environment
1 - 99
50
G
WARMUP END TIME LL
Correction value for warm-up complete time under LL environment
1 - 99
50
H
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value under LL environment
1 - 99
55
I
HL_US HEAVY LL
Correction value for heavy paper TH_US set value under LL environment
1 - 99
55
J
HL_UM OHP LL
Correction value for OHP-TH_UM set value under LL environment
1 - 99
55
K
HL_US OHP LL
Correction value for OHP-TH_US set value under LL environment
1 - 99
55
L
HL_UM E-STAR LL
Correction value for preheating TH_UM set value under LL environment
1 - 99
55
M
HL_US E-STAR LL
Correction value for preheating TH_US set value under LL environment
1 - 99
55
N
HL_UM PRE-JOB LL
Correction value for the set value of TH_UM when restoring from preheating under LL environment
1 - 99
50
O
HL_UM WARMUP_120L LL
Correction value for TH_UM set value in Warm-Up at 120 degree Cor below under LL environment
1 - 99
55
P
HL_US WARMUP_120L LL
Correction value for TH_US set value in Warm-Up at 120 degree C or below under LL environment
1 - 99
55
Q
LO_WARMUP_TIME_LL
Correction value for O, P applying time (timer from Ready complete) under LL environment
1 - 99
50
R
HL_UM WARMUP_120H LL
Correction value for TH_UM set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
S
HL_US WARMUP_120H LL
Correction value for TH_US set value in Warm-Up at 120 degree C or above under LL environment
1 - 99
55
T
HI_WU_TIME_LL
Correction value for R, S applying time (timer from Ready complete) under LL environment
1 - 99
50
U
HI_WU_FM_ON_TMP_LL
Correction value for FM prior rotation start TH_UM in Warm-Up at alpha degree C or above under LL
environment
environment
1 - 99
50
V
HI_WU_END_TIME_LL
Correction value for Warm-Up completion time in Warm-Up at alpha degree C or above under LL
environment
environment
1 - 99
50
W
HI_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or above
under LL environment
under LL environment
1 - 99
50
X
HI_WARMUP_BORDER_LL
Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment
1 - 99
50
Y
LO_WU_JOB_SET_TMP_LL
Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or below
under LL environment
under LL environment
1 - 99
50
Z
JOBEND_FUMON_TIME LL
Correction value for the after rotation time when completing a job under LL environment
1 - 99
50
AA
HI_WU_JOB_SET_TMP 2
LL
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or above
under LL environment
under LL environment
1 - 99
50
AB
LO_WU_JOB_SET_TMP 2
LL
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or below
under LL environment
under LL environment
1 - 99
50
MX-M264U SIMULATION 6 – 42
Code descriptions
- Correction value: (-49 - +49), Input value: Actual input value (1 - 99)
43-22
Purpose
Function (Purpose)
Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-04).
Section
Operation/Procedure
1)
Select an item to be set with the scroll key.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
* PLAIN BW DUP APP CNT LL: 1 count = 1s change
Other correction values: 1 count = 1 degree C change
Code descriptions
- Setting value: Target value (-49 - +49), Input value: (Actual input value) 1 - 99
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display
Content
Setting
range
Default
value
A
HL_UM PLAIN BW DUP LL
Correction value for the upper TH_UM black and white plain paper duplex under the LL
environment
environment
1 - 99
55
B
HL_US PLAIN BW DUP LL
Correction value for the upper TH_US black and white plain paper duplex under the LL
environment
environment
1 - 99
55
C
PLAIN BW DUP APP CNT LL
Correction value for applying number of sheets in black and white plain paper duplex under LL
environment
environment
1 - 99
50
D
HL_UM HEAVY BW DUP LL
Correction value for the upper TH_UM set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
E
HL_US HEAVY BW DUP LL
Correction value for the upper TH_US set value of black and white heavy paper duplex under the
LL environment
LL environment
1 - 99
55
F
HEAVY BW DUP APP CNT LL
Correction value for applying number of sheets in black and white heavy paper duplex under LL
environment
environment
1 - 99
50
TH_UM
Fusing thermistor main (Front surface of paper)
HL_UM
Heater lamp main (Heat roller for front surface of paper)
TH_US
Fusing thermistor sub (Front surface of paper)
HL_US
Heater lamp sub (Heat roller for front surface of paper)
Setting value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
MX-M264U SIMULATION 6 – 43
44
44-1
Purpose
Setting
Function (Purpose)
Used to set each correction operation func-
tion in the image forming (process) section.
tion in the image forming (process) section.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1)
Select an item to be set with the touch panel.
(The selected item is highlighted.)
(The selected item is highlighted.)
2)
Press [EXECUTE] key. (The set value is saved.)
CAUTION: Set the items to the default values unless a change is
specially required.
44-9
Purpose
Operation data display
Function (Purpose)
Used to display the result data of the high
density process control operation.
density process control operation.
Section
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
Select a target display mode with [CPY/PRN], [OTHER] keys.
Item/Display
Content
Setting range
Default value
NOTE
MD_VG
Membrane decrease (GB) Enable/Disable setting
Black text on
white
background
(Inhibit: 0=NO)
White text on
black
background
(Allow: 1=YES)
white
background
(Inhibit: 0=NO)
White text on
black
background
(Allow: 1=YES)
Enable
MD_DV_LIFE
DV life correction (GB, DVD) Enable/Disable setting
Enable
MD_ENV
Environment correction (GB, DVD) Enable/Disable setting
Enable
MD_DUPLEX
Duplex print correction (GB, DVD) Enable/Disable setting
Enable
MD_LD
Membrane decrease life correction (laser power) Enable/Disable setting
Enable
MD_LD_ENV
Environment correction (laser power) Enable/Disable setting
Enable
TN_LIFE
Enable/Disable setting of the toner density life correction
Enable
TN_ENV
Enable/Disable setting of the toner density environment correction
Enable
TN_DUPLEX
Toner density duplex print correction Enable/Disable setting
Enable
TN_COV
Enable/Disable setting of the toner density print ratio correction
Enable
TN_AREA
Enable/Disable setting of the toner density area correction
Enable
TN_DRIP
Enable/Disable setting of the toner density correction unconditional supply
Enable
TC
Enable/Disable setting of the transfer output correction
Enable
Mode
Page number
Item/Display
(*: Correction
value)
Content
Display range
Default
value
CPY/
PRN*
PRN*
1
1/2 (PROCESS)
REF (TS_OFF)
Left
GB ***
GB/DVB default value when TS is OFF
0 - 750
590
Right
DVB ***
0 - 650
450
ALL (TS_OFF)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when TS is OFF
subtraction of the correction amount
when TS is OFF
0 - 750
590
Right
DVB ***
0 - 650
450
REF (TS_ON_C)
Left
GB ***
Copy GB/DVB default value when TS is
ON
ON
0 - 750
460
Right
DVB ***
0 - 650
320
ALL(TS_ON_C)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Copy TS is ON.
subtraction of the correction amount
when Copy TS is ON.
0 - 750
460
Right
DVB ***
0 - 650
320
REF (TS_ON_P)
Left
GB ***
Printer GB/DVB default value when TS is
ON
ON
0 - 750
390
Right
DVB ***
0 - 650
250
ALL (TS_ON_P)
Left
GB ***
GB/DVB value after addition or
subtraction of the correction amount
when Printer TS is ON
subtraction of the correction amount
when Printer TS is ON
0 - 750
390
Right
DVB ***
0 - 650
250
MD_VG
Left
GB ***
Drum membrane decrease correction
amount GB value
amount GB value
0 - 255
0
MD_DV_LIFE
Left
GB ***
Process developer life correction amount
GB/DVB value
GB/DVB value
-127 - +127
0
Right
DVB ***
-127 - +127
0
MD_ENV
Left
GB ***
Environment correction amount GB/DVB
value
value
-127 - +127
0
Right
DVB ***
-127 - +127
0
MD_DUPLEX
Left
GB ***
Duplex print correction amount GB/DVB
value
value
0 - 255
0
Right
DVB ***
0 - 255
0
Click on the first or last page to see other MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) service manuals if exist.