Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ▷ View online

MX-M264U  SIMULATION  6 – 12
 
8
 
8-1
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operations of
the developing voltage in each print mode
and the control circuit.
Section
Process (Developing)
Operation/Procedure
1)
Select a mode with [TS_OFF] and [TS_ON] keys on the touch
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the setting value with 10-key. (The value specified on the
label of the high voltage PWB must be entered.)
* When the 
   key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
 
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
Section
Process (Charging)
Operation/Procedure
1)
Select a mode with [TS_OFF] and [TS_ON] keys on the touch
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the adjustment value with 10-key. (The value specified
on the label of the high voltage PWB must be entered.)
* When the 
   key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display (Mode)
Content
Adjustment 
range
Default 
value
TS_OFF
A
COPY 
DVB
Developing bias 
set value in a 
copy job (Toner 
save mode OFF)
0 - 650
450
B
PRINTER 
FAX DVB
Developing bias 
set value in a 
PRINT/FAX job 
(Toner save 
mode OFF)
0 - 650
450
TS_ON
A
COPY 
DVB
Developing bias 
set value in a 
copy job (Toner 
save mode ON)
0 - 650
320
B
PRINTER 
DVB
Developing bias 
set value in a 
print job (Toner 
save mode ON)
0 - 650
250
Item/Display (Mode)
Content
Adjustment 
range
Default 
value
TS_OFF
A
COPY 
GB
Charging/grid 
bias set value in 
a copy job (Toner 
save mode OFF)
0 - 750
590
B
PRINTER 
FAX GB
Charging/grid 
bias set value in 
a PRINT/FAX job 
(Toner save 
mode OFF)
0 - 750
590
TS_ON
A
COPY 
GB
Charging/grid 
bias set value in 
a copy job (Toner 
save mode ON)
0 - 750
460
B
PRINTER 
GB
Charging/grid 
bias set value in 
a print job (Toner 
save mode ON)
0 - 750
390
MX-M264U  SIMULATION  6 – 13
 
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check the output of the transfer
charger output voltage.
Section
Process (Transport)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec. 
When [EXECUTE] key is pressed, the output is terminated.
Item/Display
Content
Setting 
range
Default value
26cpm 
machine
31cpm 
machine
35cpm 
machine
A
+V1  F
Transfer 
bias 
reference 
value
Standard 
paper
W
Between 
papers
Single
A-1: W, +V1 F (Between 
papers), Standard paper 
front surface 
(Single/Duplex)
0 - 255
5
5
5
B
+V1 R
Duplex
A-2: W, +V1 R (Between 
papers), Standard paper 
back surface (Duplex)
0 - 255
5
5
5
C
+V2 F
Paper
Single
A-3: W, +V2 F, Standard 
paper front surface 
(Single/Duplex)
0 - 255
14
18
20
D
+V2 R
Duplex
A-4: W, +V2 R, Standard 
paper back surface 
(Duplex)
0 - 255
12
16
14
E
+V1 S-F
Standard 
paper
N1jp
Between 
papers
Single
B-1: N1jp, +V1 S-F 
(Between papers), 
Standard paper front 
surface (Single/Duplex)
0 - 255
5
5
5
F
+V1 S-R
Duplex
B-2: N1jp, +V1 S-R 
(Between papers), 
Standard paper back 
surface (Duplex)
0 - 255
5
5
5
G
+V2 S-F
Paper
Single
B-3: N1jp, +V2 S-F, 
Standard paper front 
surface (Single/Duplex)
0 - 255
14
18
20
H
+V2 S-F
Duplex
B-4: N1jp, +V2 S-F, 
Standard paper back 
surface (Duplex)
0 - 255
14
18
20
I
+V1 XS-F
Standard 
paper
N2jp
Between 
papers
Single
C-1: N2jp, +V1 XS-F 
(Between papers), 
Standard paper front 
surface (Single/Duplex)
0 - 255
5
5
5
J
+V1 XS-R
Duplex
C-2: N2jp, +V1 XS-R 
(Between papers), 
Standard paper back 
surface (Duplex)
0 - 255
5
5
5
K
+V2 XS-F
Paper
Single
C-3: N2jp, +V2 XS-F, 
Standard paper front 
surface (Single/Duplex)
0 - 255
14
18
20
L
+V2 XS-R
Duplex
C-4: N2jp, +V2 XS-R, 
Standard paper back 
surface (Duplex)
0 - 255
14
18
20
M
+V1 THICK
Heavy 
paper
>LTR
Between papers
D-1: > LTR, +V1 THICK 
(Between papers), 
Heavy paper
0 - 255
5
5
5
N
+V2 THICK
Paper
D-2: > LTR, +V2 THICK, 
Heavy paper
0 - 255
10
14
16
O
+V1 THICK S
<_LTR
Between papers
E-1: <_ LTR, +V1 THICK 
S (Between papers), 
Heavy paper
0 - 255
5
5
5
P
+V2 THICK S
Paper
E-2: <_ LTR, +V2 THICK 
S, Heavy paper
0 - 255
12
14
16
MX-M264U  SIMULATION  6 – 14
 
9
 
9-2
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the sen-
sors and detectors in the paper reverse
section (duplex section) and its control cir-
cuit.
Section
Duplex
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
The code names of the sensors and the detectors which are active
are highlighted.
 
9-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the load in
the paper reverse section (duplex section)
and its control circuit.
Section
Duplex
Operation/Procedure
1)
Select the item to be operation checked with the touch panel
key.
2)
Press [EXECUTE] key.
The selected load performs the operation.
When [EXECUTE] key is pressed, the operation is terminated.
Q
+V1 THIN
Transfer 
bias 
reference 
value
Thin 
paper
>LTR
Between papers
D-7: > LTR, +V1 THIN 
(Between papers), 
Thin paper
0 - 255
5
5
5
R
+V2 THIN
Paper
D-8: > LTR, +V2 THIN, 
Thin paper
0 - 255
12
18
20
S
+V1 THIN S
<_LTR
Between papers
E-7: <_ LTR, +V1 THIN S 
(Between papers), 
Thin paper
0 - 255
5
5
5
T
+V2 THIN S
Paper
E-8: <_ LTR, +V2 THIN 
S, Thin paper
0 - 255
12
18
20
U
+V1 LABEL
Label 
sheet
>LTR
Between papers
D-3: <_ LTR, +V1 LABEL 
(Between papers), 
Label sheet
0 - 255
5
5
5
V
+V2 LABEL
Paper
D-4: > LTR, +V2 LABEL, 
Label sheet
0 - 255
12
18
20
W
+V1 LABEL S
<_LTR
Between papers
E-3: <_ LTR, +V1 LABEL 
S (Between papers), 
Label sheet
0 - 255
5
5
5
X
+V2 LABEL S
Paper
E-4: <_ LTR, +V2 LABEL 
S, Label sheet
0 - 255
12
14
16
Y
+V1 OHP
OHP
>LTR
Between papers
D-5: > LTR, +V1 OHP 
(Between papers), OHP
0 - 255
5
5
5
Z
+V2 OHP
Paper
D-6: > LTR, +V2 OHP, 
OHP
0 - 255
8
14
16
AA
+V1 OHP S
<_LTR
Between papers
E-5: <_ LTR, +V1 OHP S 
(Between papers), OHP
0 - 255
5
5
5
AB
+V2 OHP S
Paper
E-6: <_ LTR, +V2 OHP 
S, OHP
0 - 255
12
18
20
AC
+V1 POSTCARD
Postcard/
Envelope
>100mm
Between papers
D-9: > 100mm, +V1 
POSTCARD (Between 
papers), 
Postcard/Envelope
0 - 255
5
5
5
AD
+V2 POSTCARD
Paper
D-10: > 100mm, +V2 
POSTCARD, 
Postcard/Envelope
0 - 255
16
26
26
AE
+V1 POSTCARD S
<_100m
m
Between papers
E-9: <_ 100mm, +V1 
POSTCARD S (Between 
papers), 
Postcard/Envelope
0 - 255
5
5
5
AF
+V2 POSTCARD S
Paper
E-10: <_ 100mm, +V2 
POSTCARD S, 
Postcard/Envelope
0 - 255
16
26
26
Item/Display
Content
Setting 
range
Default value
26cpm 
machine
31cpm 
machine
35cpm 
machine
Display
Content
APPD1
ADU paper transport detector 1
Display
Content
ADUM
ADU motor
MX-M264U  SIMULATION  6 – 15
 
10
 
10-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the toner
supply mechanism (toner motor) and the
related circuit.
Section
Process (Developing)
Operation/Procedure
1)
Select a target of the operation check with the touch panel key.
2)
Press [EXECUTE] key.
The selected load operation is performed for 10 sec.
When [EXECUTE] key is pressed, the operation is terminated.
CAUTION: This simulation must be executed without installing the
toner cartridges.
If this simulation is executed with the toner cartridges
installed, toner will be forcibly supplied to the develop-
ing unit, resulting in overtoner.
If this simulation is erroneously executed with the toner
cartridges installed, overtoner state may be deleted by
making a few black background copy in the copy mode.
 
13
 
13--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U1" trouble.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
 
14
 
14--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag H3, H4, H5
troubles.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
 
16
 
16--
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U2" trouble.
Section
MFP PWB / PCU PWB / SCU PWB
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
 
17
 
17--
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "PF" trouble.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
 
21
 
21-1
Purpose
Setting
Function (Purpose)
Used to set the maintenance cycle.
Section
Operation/Procedure
* Do not change the default setting value of the maintenance
counter on SIM21-1. The replacement timing of the fusing clean-
ing roller, the filter and PS paper dust removal cleaner may not
clarify.
1)
Select a target item of setting with scroll key on the touch
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Display
Content
TNM
Toner motor
Item/Display
Content
Setting 
range
Default 
value
A
MAINTENANCE 
COUNTER 
(TOTAL)
Maintenance 
counter (Total)
0:
Default
1 - 300: 
1K - 300K
999: Free
26CPM: 75K
31/35CPM: 
100K