MX-M264U SIMULATION 6 – 12
8
8-1
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operations of
the developing voltage in each print mode
and the control circuit.
the developing voltage in each print mode
and the control circuit.
Section
Process (Developing)
Operation/Procedure
1)
Select a mode with [TS_OFF] and [TS_ON] keys on the touch
panel.
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the setting value with 10-key. (The value specified on the
label of the high voltage PWB must be entered.)
label of the high voltage PWB must be entered.)
* When the
key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
8-2
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check and adjust the operation of
the main charger grid voltage in each
printer mode and the control circuit.
the main charger grid voltage in each
printer mode and the control circuit.
Section
Process (Charging)
Operation/Procedure
1)
Select a mode with [TS_OFF] and [TS_ON] keys on the touch
panel.
panel.
2)
Select a target item to be adjusted with scroll keys.
3)
Enter the adjustment value with 10-key. (The value specified
on the label of the high voltage PWB must be entered.)
on the label of the high voltage PWB must be entered.)
* When the
key is pressed, the setting value of each
item can be changed with 1up (1down) collectively.
4)
Press [EXECUTE] key.
The set value is saved and the voltage entered with step 3) is
output for 30 sec.
output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display (Mode)
Content
Adjustment
range
Default
value
TS_OFF
A
COPY
DVB
DVB
Developing bias
set value in a
copy job (Toner
save mode OFF)
set value in a
copy job (Toner
save mode OFF)
0 - 650
450
B
PRINTER
FAX DVB
FAX DVB
Developing bias
set value in a
PRINT/FAX job
(Toner save
mode OFF)
set value in a
PRINT/FAX job
(Toner save
mode OFF)
0 - 650
450
TS_ON
A
COPY
DVB
DVB
Developing bias
set value in a
copy job (Toner
save mode ON)
set value in a
copy job (Toner
save mode ON)
0 - 650
320
B
PRINTER
DVB
DVB
Developing bias
set value in a
print job (Toner
save mode ON)
set value in a
print job (Toner
save mode ON)
0 - 650
250
Item/Display (Mode)
Content
Adjustment
range
Default
value
TS_OFF
A
COPY
GB
GB
Charging/grid
bias set value in
a copy job (Toner
save mode OFF)
bias set value in
a copy job (Toner
save mode OFF)
0 - 750
590
B
PRINTER
FAX GB
FAX GB
Charging/grid
bias set value in
a PRINT/FAX job
(Toner save
mode OFF)
bias set value in
a PRINT/FAX job
(Toner save
mode OFF)
0 - 750
590
TS_ON
A
COPY
GB
GB
Charging/grid
bias set value in
a copy job (Toner
save mode ON)
bias set value in
a copy job (Toner
save mode ON)
0 - 750
460
B
PRINTER
GB
GB
Charging/grid
bias set value in
a print job (Toner
save mode ON)
bias set value in
a print job (Toner
save mode ON)
0 - 750
390
MX-M264U SIMULATION 6 – 13
8-6
Purpose
Operation test/check/adjustment
Function (Purpose)
Used to check the output of the transfer
charger output voltage.
charger output voltage.
Section
Process (Transport)
Operation/Procedure
1)
Select a target item to be adjusted with scroll keys.
2)
Enter the set value with 10-key.
3)
Press [EXECUTE] key.
The set value is saved and the voltage corresponding to the
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
set value is output for 30 sec.
When [EXECUTE] key is pressed, the output is terminated.
Item/Display
Content
Setting
range
Default value
26cpm
machine
31cpm
machine
35cpm
machine
A
+V1 F
Transfer
bias
reference
value
bias
reference
value
Standard
paper
W
Between
papers
Single
A-1: W, +V1 F (Between
papers), Standard paper
front surface
(Single/Duplex)
papers), Standard paper
front surface
(Single/Duplex)
0 - 255
5
5
5
B
+V1 R
Duplex
A-2: W, +V1 R (Between
papers), Standard paper
back surface (Duplex)
papers), Standard paper
back surface (Duplex)
0 - 255
5
5
5
C
+V2 F
Paper
Single
A-3: W, +V2 F, Standard
paper front surface
(Single/Duplex)
paper front surface
(Single/Duplex)
0 - 255
14
18
20
D
+V2 R
Duplex
A-4: W, +V2 R, Standard
paper back surface
(Duplex)
paper back surface
(Duplex)
0 - 255
12
16
14
E
+V1 S-F
Standard
paper
N1jp
Between
papers
Single
B-1: N1jp, +V1 S-F
(Between papers),
Standard paper front
surface (Single/Duplex)
(Between papers),
Standard paper front
surface (Single/Duplex)
0 - 255
5
5
5
F
+V1 S-R
Duplex
B-2: N1jp, +V1 S-R
(Between papers),
Standard paper back
surface (Duplex)
(Between papers),
Standard paper back
surface (Duplex)
0 - 255
5
5
5
G
+V2 S-F
Paper
Single
B-3: N1jp, +V2 S-F,
Standard paper front
surface (Single/Duplex)
Standard paper front
surface (Single/Duplex)
0 - 255
14
18
20
H
+V2 S-F
Duplex
B-4: N1jp, +V2 S-F,
Standard paper back
surface (Duplex)
Standard paper back
surface (Duplex)
0 - 255
14
18
20
I
+V1 XS-F
Standard
paper
N2jp
Between
papers
Single
C-1: N2jp, +V1 XS-F
(Between papers),
Standard paper front
surface (Single/Duplex)
(Between papers),
Standard paper front
surface (Single/Duplex)
0 - 255
5
5
5
J
+V1 XS-R
Duplex
C-2: N2jp, +V1 XS-R
(Between papers),
Standard paper back
surface (Duplex)
(Between papers),
Standard paper back
surface (Duplex)
0 - 255
5
5
5
K
+V2 XS-F
Paper
Single
C-3: N2jp, +V2 XS-F,
Standard paper front
surface (Single/Duplex)
Standard paper front
surface (Single/Duplex)
0 - 255
14
18
20
L
+V2 XS-R
Duplex
C-4: N2jp, +V2 XS-R,
Standard paper back
surface (Duplex)
Standard paper back
surface (Duplex)
0 - 255
14
18
20
M
+V1 THICK
Heavy
paper
>LTR
Between papers
D-1: > LTR, +V1 THICK
(Between papers),
Heavy paper
(Between papers),
Heavy paper
0 - 255
5
5
5
N
+V2 THICK
Paper
D-2: > LTR, +V2 THICK,
Heavy paper
Heavy paper
0 - 255
10
14
16
O
+V1 THICK S
<_LTR
Between papers
E-1: <_ LTR, +V1 THICK
S (Between papers),
Heavy paper
S (Between papers),
Heavy paper
0 - 255
5
5
5
P
+V2 THICK S
Paper
E-2: <_ LTR, +V2 THICK
S, Heavy paper
S, Heavy paper
0 - 255
12
14
16
MX-M264U SIMULATION 6 – 14
9
9-2
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the sen-
sors and detectors in the paper reverse
section (duplex section) and its control cir-
cuit.
sors and detectors in the paper reverse
section (duplex section) and its control cir-
cuit.
Section
Duplex
Operation/Procedure
The operating conditions of the sensors and detectors are dis-
played.
played.
The code names of the sensors and the detectors which are active
are highlighted.
are highlighted.
9-3
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the load in
the paper reverse section (duplex section)
and its control circuit.
the paper reverse section (duplex section)
and its control circuit.
Section
Duplex
Operation/Procedure
1)
Select the item to be operation checked with the touch panel
key.
key.
2)
Press [EXECUTE] key.
The selected load performs the operation.
When [EXECUTE] key is pressed, the operation is terminated.
Q
+V1 THIN
Transfer
bias
reference
value
bias
reference
value
Thin
paper
>LTR
Between papers
D-7: > LTR, +V1 THIN
(Between papers),
Thin paper
(Between papers),
Thin paper
0 - 255
5
5
5
R
+V2 THIN
Paper
D-8: > LTR, +V2 THIN,
Thin paper
Thin paper
0 - 255
12
18
20
S
+V1 THIN S
<_LTR
Between papers
E-7: <_ LTR, +V1 THIN S
(Between papers),
Thin paper
(Between papers),
Thin paper
0 - 255
5
5
5
T
+V2 THIN S
Paper
E-8: <_ LTR, +V2 THIN
S, Thin paper
S, Thin paper
0 - 255
12
18
20
U
+V1 LABEL
Label
sheet
sheet
>LTR
Between papers
D-3: <_ LTR, +V1 LABEL
(Between papers),
Label sheet
(Between papers),
Label sheet
0 - 255
5
5
5
V
+V2 LABEL
Paper
D-4: > LTR, +V2 LABEL,
Label sheet
Label sheet
0 - 255
12
18
20
W
+V1 LABEL S
<_LTR
Between papers
E-3: <_ LTR, +V1 LABEL
S (Between papers),
Label sheet
S (Between papers),
Label sheet
0 - 255
5
5
5
X
+V2 LABEL S
Paper
E-4: <_ LTR, +V2 LABEL
S, Label sheet
S, Label sheet
0 - 255
12
14
16
Y
+V1 OHP
OHP
>LTR
Between papers
D-5: > LTR, +V1 OHP
(Between papers), OHP
(Between papers), OHP
0 - 255
5
5
5
Z
+V2 OHP
Paper
D-6: > LTR, +V2 OHP,
OHP
OHP
0 - 255
8
14
16
AA
+V1 OHP S
<_LTR
Between papers
E-5: <_ LTR, +V1 OHP S
(Between papers), OHP
(Between papers), OHP
0 - 255
5
5
5
AB
+V2 OHP S
Paper
E-6: <_ LTR, +V2 OHP
S, OHP
S, OHP
0 - 255
12
18
20
AC
+V1 POSTCARD
Postcard/
Envelope
Envelope
>100mm
Between papers
D-9: > 100mm, +V1
POSTCARD (Between
papers),
Postcard/Envelope
POSTCARD (Between
papers),
Postcard/Envelope
0 - 255
5
5
5
AD
+V2 POSTCARD
Paper
D-10: > 100mm, +V2
POSTCARD,
Postcard/Envelope
POSTCARD,
Postcard/Envelope
0 - 255
16
26
26
AE
+V1 POSTCARD S
<_100m
m
Between papers
E-9: <_ 100mm, +V1
POSTCARD S (Between
papers),
Postcard/Envelope
POSTCARD S (Between
papers),
Postcard/Envelope
0 - 255
5
5
5
AF
+V2 POSTCARD S
Paper
E-10: <_ 100mm, +V2
POSTCARD S,
Postcard/Envelope
POSTCARD S,
Postcard/Envelope
0 - 255
16
26
26
Item/Display
Content
Setting
range
Default value
26cpm
machine
31cpm
machine
35cpm
machine
Display
Content
APPD1
ADU paper transport detector 1
Display
Content
ADUM
ADU motor
MX-M264U SIMULATION 6 – 15
10
10-1
Purpose
Operation test/check
Function (Purpose)
Used to check the operations of the toner
supply mechanism (toner motor) and the
related circuit.
supply mechanism (toner motor) and the
related circuit.
Section
Process (Developing)
Operation/Procedure
1)
Select a target of the operation check with the touch panel key.
2)
Press [EXECUTE] key.
The selected load operation is performed for 10 sec.
When [EXECUTE] key is pressed, the operation is terminated.
CAUTION: This simulation must be executed without installing the
toner cartridges.
If this simulation is executed with the toner cartridges
installed, toner will be forcibly supplied to the develop-
ing unit, resulting in overtoner.
installed, toner will be forcibly supplied to the develop-
ing unit, resulting in overtoner.
If this simulation is erroneously executed with the toner
cartridges installed, overtoner state may be deleted by
making a few black background copy in the copy mode.
cartridges installed, overtoner state may be deleted by
making a few black background copy in the copy mode.
13
13--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U1" trouble.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
14
14--
Purpose
Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag H3, H4, H5
troubles.
troubles.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
16
16--
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "U2" trouble.
Section
MFP PWB / PCU PWB / SCU PWB
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
17
17--
Purpose
Clear/Cancel (Trouble etc.)
Function (Purpose)
Used to cancel the self-diag "PF" trouble.
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key to execute cancellation of the trouble.
21
21-1
Purpose
Setting
Function (Purpose)
Used to set the maintenance cycle.
Section
Operation/Procedure
* Do not change the default setting value of the maintenance
counter on SIM21-1. The replacement timing of the fusing clean-
ing roller, the filter and PS paper dust removal cleaner may not
clarify.
ing roller, the filter and PS paper dust removal cleaner may not
clarify.
1)
Select a target item of setting with scroll key on the touch
panel.
panel.
2)
Enter the set value with 10-key.
3)
Press [OK] key. (The set value is saved.)
Display
Content
TNM
Toner motor
Item/Display
Content
Setting
range
Default
value
A
MAINTENANCE
COUNTER
(TOTAL)
COUNTER
(TOTAL)
Maintenance
counter (Total)
counter (Total)
0:
Default
1 - 300:
1K - 300K
999: Free
Default
1 - 300:
1K - 300K
999: Free
26CPM: 75K
31/35CPM:
100K
31/35CPM:
100K
Click on the first or last page to see other MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) service manuals if exist.