DOWNLOAD Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ↓ Size: 20.02 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M264N MX-M264NR MX-M264NV MX-M264U MX-M314N MX-M314NR MX-M314NV MX-M314U MX-M354N MX-M354NR MX-M354U (serv.man7)
Pages
127
Size
20.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised April 2016).
File
mx-m264n-mx-m264nr-mx-m264nv-mx-m264u-mx-m314n-mx-.pdf
Date

Sharp MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) Service Manual ▷ View online

MX-M264U  ADJUSTMENTS AND SETTINGS  5 – 31
3)
Make a normal copy and obtain the copy magnification ratio.
Go to the copy mode, and make a copy.
4)
Check that the copy magnification ratio is within the specified
range (100 
 1.0%).
If the copy magnification ratio is within the specified range (100
 1.0%), the adjustment is completed. If the copy magnification
ratio is not within the specified range, perform the following
procedure.
5)
Change the CCD (SUB) adjustment value of Simulation 48-1.
When the adjustment value is increased, the copy magnifica-
tion ratio in the sub scanning direction is increased.
When the adjustment value is changed by 1, the copy magnifi-
cation ratio is changed by about 0.1%.
Repeat the procedures 3) - 5) until the copy magnification ratio is
within the specified range (100 
 1.0%).
 
13-C
Scan image magnification ratio adjustment 
(main scanning direction) 
(Manual adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When U2 trouble occurs.
* When the copy magnification ratio of the RSPF mode copy
image in the main scanning direction is not proper.
* When the RSPF is disassembled.
a. Adjustment procedures
1)
Place the duplex adjustment chart shown below on the docu-
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both sides and
both surfaces of the paper at 10mm from each edge.
2)
Make a duplex copy at the normal ratio on A4 paper.
3)
Measure the images on the copy paper and the original
images.
4)
Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If the image magnification ratio is within the specified range
(100 
 0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5)
Enter the SIM 48-1 mode.
RSPF
6)
Select an adjustment item of SPF (MAIN)/SPFB (MAIN) with
the scroll key.
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
(Example 1)
Copy A
(Shorter than
the original)
(Example 2)
Copy B
(Longer than
the original)
Scale
(Original)
Copy magnifi-
cation ratio
(Original dimension - Copy dimension)
Original dimension
100%
A4 size
(Both the front surface
and the back surface)
10mm
10mm
Paper pass direction
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (MAIN)
Main scanning direction image magnification ratio 
(Front surface)
SPFB (MAIN) Main scanning direction image magnification ratio 
(Back surface)
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
MX-M264U  ADJUSTMENTS AND SETTINGS  5 – 32
7)
Enter an adjustment value with 10-key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased. When the adjustment value is changed
by 1, the image magnification ratio is changed by 0.02%.
8)
Make a normal copy and obtain the copy magnification ratio.
Repeat the procedures of 1) - 8) until a satisfactory result is
obtained.
 
13-D
Scan image magnification ratio adjustment 
(sub scanning direction) (Manual 
adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the SCAN CONTROL PWB is replaced.
* When the EEPROM on the SCAN CONTROL PWB is replaced.
* When U2 trouble occurs.
* When the copy magnification ratio of the RSPF mode copy
image in the sub scanning direction is not proper.
* When the RSPF is disassembled.
1)
Place the duplex adjustment chart shown below on the docu-
ment tray of the RSPF.
The adjustment chart is prepared by the following procedures.
Use A4 (11" x 8.5") paper, and put marks on both sides and
both surfaces of the paper at 10mm from each edge.
2)
Make a duplex copy at the normal ratio on A4 paper.
3)
Measure the images on the copy paper and the original
images.
4)
Obtain the image magnification ratio according to the following
formula:
Image magnification ratio = Original size / Original size x 100
(%)
Image magnification ratio = 99 / 100 x 100 = 99 (%)
If the image magnification ratio is within the specified range
(100 
 0.8%), there is no need to perform the adjustment.
If it is not within the specified range, perform the following pro-
cedures.
5)
Enter the SIM 48-1 mode.
6)
Select an adjustment item with the scroll key.
7)
Enter an image magnification ratio adjustment value with 10-
key, and press [OK] key.
When the adjustment value is increased, the image magnifica-
tion ratio is increased.
When the adjustment value is changed by 1, the image magni-
fication ratio is changed by 0.1%.
8)
Make a normal copy and obtain the copy magnification ratio.
Repeat the procedures of 1) - 8) until a satisfactory result is
obtained.
A4 size
10mm
10mm
Paper pass direction
original
copy
10
50
100
150
200
10
50
100
150
200
Item
Display
Content
Setting 
range
Default 
value
A
CCD(MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
B
CCD(SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
1 - 99
50
C
SPF(MAIN)
RSPF document front 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
D
SPF(SUB)
RSPF document front 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
E
SPFB(MAIN)
RSPF document back 
surface magnification ratio 
adjustment (Main scan)
1 - 99
50
F
SPFB(SUB)
RSPF document back 
surface magnification ratio 
adjustment (Sub scan)
1 - 99
50
SPF (SUB)
Sub scanning direction image magnification ratio 
(Front surface)
SPFB (SUB)
Sub scanning direction image magnification ratio 
(Back surface)
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
0$*1,),&$7,21$'-8670(17
˷̚˹
˖&&'0$,1
˖&&'68%
˖63)0$,1
˖63)68%
˖63)%0$,1
˖63)%68%
2.
MX-M264U  ADJUSTMENTS AND SETTINGS  5 – 33
 
ADJ 14
Scan image off-center 
adjustment 
(Manual adjustment)
NOTE: Normally if the adjustment is executed by ADJ 3 (automatic
adjustment), there is no need to execute this adjustment.
Only when the manual adjustment is required, execute this
adjustment.
In other words, this manual adjustment is executed when a
satisfactory result is not obtained from the automatic
adjustment (ADJ 3).
 
14-A
Scan image off-center adjustment (Manual 
adjustment) (Document table mode)
This adjustment must be performed in the following cases:
* When the scanner (reading) section is disassembled.
* When the scanner (reading) unit is replaced.
* When a U2 trouble occurs.
* When the scanner control PWB is replaced.
* When the EEPROM on the scanner control PWB is replaced.
1)
Make a copy of the adjustment chart (made by yourself) in the
adjustment mode (document table).
2)
Check the copy image center position.
If A - B = 
 1.0mm, the adjustment is not required.
If the above condition is not satisfied, perform the following
procedures.
3)
Enter the SIM 50-12 mode.
4)
Select the adjustment mode OC with the scroll key.
5)
Enter the adjustment value with 10-key, and press [OK] key.
The entered value is set.
When the set value is increased, the main scanning print posi-
tion is shifted to the front side by 0.1mm.
6)
Go to the copy mode, and make a copy.
Repeat the procedures of 1) - 6) until the above condition is satis-
fied.
 
14-B
Scan image off-center adjustment 
(Manual adjustment) (RSPF mode)
This adjustment must be performed in the following cases:
* When the scan control PWB is replaced.
* When the EEPROM on the scan control PWB is replaced.
* When the scanner (reading) section is disassembled.
* When the scanner (reading) section is replaced.
* When U2 trouble occurs.
* When the RSPF section is disassembled.
* When the RSPF unit is replaced.
CAUTION: To execute this adjustment, it is required that the ADJ
14A Scan image off-center adjustment (Document table
mode) must have been properly adjusted.
1)
Prepare the adjustment chart.
Draw a line at the center of the front surface and the back sur-
face of A4 (11" x 8.5") paper in parallel with the paper transport
direction.
B
A = B
A
B'
A' - B' =
1.0mm
A'
(100%)
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
25,*,1$/&(17(52))6(76(783
˷̚˹
˖2&
˖63)6,'(
˖63)6,'(
2.
Paper transport direction
Front surface
Back surface
Draw a line at the center of the
front surface and the back surface
of paper in parallel with the paper
transport direction.
MX-M264U  ADJUSTMENTS AND SETTINGS  5 – 34
2)
Set the adjustment chart to the RSPF.
3)
Make a duplex copy in the normal magnification ratio from the
manual paper feed tray, and check the image position on the
front surface and the back surface of the copy paper.
If the difference is within the range of 0 
 2.7mmm there is no
need to perform the adjustment.
If the adjustment is required, perform the following procedures.
4)
Enter the SIM 50-12 or 50-6 mode.
SIM50-12
A - C: When the adjustment value is increased, the image
position is shifted to the rear frame side.
1step = 0.1mm
SIM50-6
* Item A, B: When the adjustment value is increased, the scan
timing is delayed.
* Item C - H: When the adjustment value is increased, the
image loss is increased.
* Item A - H: 1 step = 0.1mm change
* The SPF rear edge image loss setting is provided for
countermeasures against the case when shades are
produced.
5)
Select an adjustment mode with the scroll key.
SIM50-12
SIM50-6
6)
Enter an adjustment value with 10-key, and press [OK] key.
(Change for change in the adjustment value: 0.1mm/step)
(When the adjustment value is increased, the print image is
shifted to the rear.)
Repeat the procedures of 2) - 6) until a satisfactory result is
obtained.
Item
Display
Content
Setting 
range
Default 
value
A
OC
Document table image off-
center adjustment
1 - 99
50
B
SPF(SIDE1)
SPF front surface image off-
center adjustment
1 - 99
50
C
SPF(SIDE2)
SPF back surface image off-
center adjustment
1 - 99
50
original
copy
a
b
ǂǂǂ6,08/$7,21ǂ 12
&/26(
7(67
25,*,1$/&(17(52))6(76(783
˷̚˹
˖2&
˖63)6,'(
˖63)6,'(
2.
SIM50-12
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
/($'('*($'-8670(179$/8(63)
˷̚˹
˖6,'(
˖6,'(
˖/($'B('*(6,'(
˖)5217B5($56,'(
˖/($'B('*(6,'(
˖75$,/B('*(6,'(
˖)5217B5($56,'(
˖75$,/B('*(6,'(
˖2))6(7B63)
˖2))6(7B63)
˖6&$1B63(('B63)
2.
SIM50-6
˖6&$1B63(('B63)
Item/Display
Content
Setting 
range
Default 
value
A
SIDE1
Front surface 
document scan 
position adjustment 
(CCD)
1 - 99
50
B
SIDE2
Back surface 
document scan 
position adjustment 
(CCD)
1 - 99
50
C
Image 
loss 
amount 
setting 
SIDE1
LEAD_EDGE 
(SIDE1)
Front surface lead 
edge image loss 
amount setting
0 - 99
20
D
FRONT_REAR 
(SIDE1)
Front surface side 
image loss amount 
setting
0 - 99
20
E
TRAIL_EDGE 
(SIDE1)
Front surface rear 
edge image loss 
amount setting
0 - 99
40
F
Image 
loss 
amount 
setting 
SIDE2
LEAD_EDGE 
(SIDE2)
Back surface lead 
edge image loss 
amount setting
0 - 99
20
G
FRONT_REAR 
(SIDE2)
Back surface side 
image loss amount 
setting
0 - 99
20
H
TRAIL_EDGE 
(SIDE2)
Back surface rear 
edge image loss 
amount setting
0 - 99
40
I
OFFSET_SPF1
RSPF front surface 
document off-center 
adjustment
1 - 99
50
J
OFFSET_SPF2
RSPF back surface 
document off-center 
adjustment
1 - 99
50
K
SCAN_SPEED_SPF1
RSPF document 
front surface 
magnification ratio 
adjustment (Sub 
scan)
1 - 99
50
L
SCAN_SPEED_SPF2
RSPF document 
back surface 
magnification ratio 
adjustment (Sub 
scan)
1 - 99
50
SPF(SIDE1)
Front surface mode
SPF(SIDE2)
Back surface mode
OFFSET SPF1
Front surface mode
OFFSET SPF2
Back surface mode
Page of 127
Display

Click on the first or last page to see other MX-M264N / MX-M264NR / MX-M264NV / MX-M264U / MX-M314N / MX-M314NR / MX-M314NV / MX-M314U / MX-M354N / MX-M354NR / MX-M354U (serv.man7) service manuals if exist.