Sharp MX-FXX3 Service Manual ▷ View online
MXFXX3 SIMULATIONS, FAX SOFTWARE SWITCH 3 – 27
• 4.3 Inch LCD model
• 7.0/8.5 Inch LCD model
66-61
Purpose
Setting
Function (Purpose) Used to display the FAX-related soft SW
(100 - 170) on the LCD to allow changing
the soft SW while checking with the LCD.
the soft SW while checking with the LCD.
Section
FAX
Operation/Procedure
1)
1)
Enter the [SW NO] with 10-key.
* When [C] key is pressed, the entered value of [SW NO] is
* When [C] key is pressed, the entered value of [SW NO] is
cleared.
2)
Press [DATA] button.
The soft SW data entered in procedure 1) is displayed.
* When [SW NO] button is pressed, the display returns to the
The soft SW data entered in procedure 1) is displayed.
* When [SW NO] button is pressed, the display returns to the
initial screen.
3)
Enter the number corresponding to the bit to be changed with
10-key.
[1]
10-key.
[1]
[0]
[0]
[1]
* When [SW NO] button is pressed, the display returns to the
initial screen.
4)
When [EXECUTE] button is pressed, it is highlighted and the
setting is saved.
After saving the setting, [EXECUTE] button returns to the nor-
mal display.
setting is saved.
After saving the setting, [EXECUTE] button returns to the nor-
mal display.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
• 4.3 Inch LCD model
• 7.0/8.5 Inch LCD model
1
Thru Num.20
Through number 20
0840
Max. 4
Though Number20
Thru Num.21
Through number 21
090
Max. 4
Though Number21
Thru Num.22
Through number 22
0990
Max. 4
Though Number22
Res. Thru Num.1
Reserve Through number 1
Null
Max. 4
Reserve Though Number
Res. Thru Num.2
Reserve Through number 2
Null
Max. 4
Reserve Though Number2
Res. Thru Num.3
Reserve Through number 3
Null
Max. 4
Reserve Though Number3
2
Res. Thru Num.4
Reserve Through number 4
Null
Max. 4
Reserve Though Number4
Res. Thru Num.5
Reserve Through number 5
Null
Max. 4
Reserve Though Number5
Res. Thru Num.6
Reserve Through number 6
Null
Max. 4
Reserve Though Number6
Res. Thru Num.7
Reserve Through number 7
Null
Max. 4
Reserve Though Number7
Res. Thru Num.8
Reserve Through number 8
Null
Max. 4
Reserve Though Number8
Item
Key display
Data kind
Default
Number of digits
Title line display when entering number
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
$&56(77,1*/RFDO&DUULHU1XPEHU
7(67
/RFDO&DU1XP
6(7
/RQJ&DU1XP
2YHU&DU1XP
%\SDVV1XP
8VHU$UHD&G
0DFKLQH&RGH
9HUVLRQ
7KUX1XP
35(6(17
1(:
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
$&56(77,1*/RFDO&DUULHU1XPEHU
(;(&87(
35(6(17˖
ǂǂ1(:˖
ǂǂ1(:˖
6(7
/RFDO&DUULHU1XP
/RQJ&DUULHU1XP
%\SDVV1XP
2YHU&DUULHU1XP
8VHU$UHD&RGH
0DFKLQH&RGH
7KUX1XP
9HUVLRQ
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
7KUX1XP
5HV7KUX1XP
5HV7KUX1XP
5HV7KUX1XP
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)$;62)76:6(77,1*
7(67
6:12
'$7$
6:1R
(;(&87(
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)$;62)76:6(77,1*
(;(&87(
6:1R
'$7$
䋺
䋺
6:1R
MXFXX3 SIMULATIONS, FAX SOFTWARE SWITCH 3 – 28
2. FAX software switch
A. FAX Soft SW List
Lines
SW
No.
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings
1
1-8
Country code
Control is performed according to the set country code.
The destination setting that is set in SIM66-2 as the image
send function is reflected.
The country code setting cannot be directly made from this
SW.
The destination setting that is set in SIM66-2 as the image
send function is reflected.
The country code setting cannot be directly made from this
SW.
1
North America
* For codes of the other
* For codes of the other
countries, refer to the
page of SIM 66-2
setting.
page of SIM 66-2
setting.
0
1
1
0
1
0
1
1
1
0
1
0
1
SW
No.
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings
2
1-4
Calling
Make time (10PPS)
setting
setting
Setting of make time when dialling at 10PPS.
Make time can be set from 29 to 44ms in 1ms increments by
binary inputting N over the range of 0 to 15 (N + 29ms).
Make time can be set from 29 to 44ms in 1ms increments by
binary inputting N over the range of 0 to 15 (N + 29ms).
1
"1011": 40ms
(Other country)
"0100": 33ms (Malaysia/
Taiwan/South Africa/
Brazil)
"0110": 35ms
(New Zealand/India/
Hong Kong)
"1000": 37ms (Australia)
"1001": 38ms
(China/Singapore/
Thailand)
(Other country)
"0100": 33ms (Malaysia/
Taiwan/South Africa/
Brazil)
"0110": 35ms
(New Zealand/India/
Hong Kong)
"1000": 37ms (Australia)
"1001": 38ms
(China/Singapore/
Thailand)
Adjustment
value
value
0
1
1
5-8
Calling
Break time setting
(10PPS)
(10PPS)
Setting of break time when dialling at 10PPS.
Break time can be set from 56 to 71ms by in 1ms increments
binary inputting N over the range of 0 to 15 (N + 56ms).
Break time can be set from 56 to 71ms by in 1ms increments
binary inputting N over the range of 0 to 15 (N + 56ms).
0
"0100": 60ms
(Other country)
"0110": 62ms
(China/Singapore/
Thailand/Hong Kong)
"0111": 63ms (Australia)
"1001": 65ms
(New Zealand/India/
Hong Kong)
"1011": 67ms
(Malaysia/Taiwan/
South Africa/Brazil)
(Other country)
"0110": 62ms
(China/Singapore/
Thailand/Hong Kong)
"0111": 63ms (Australia)
"1001": 65ms
(New Zealand/India/
Hong Kong)
"1011": 67ms
(Malaysia/Taiwan/
South Africa/Brazil)
Adjustment
value
value
1
0
0
3
1-4
Calling
Minimum pause time
(10PPS) setting
(10PPS) setting
Setting of minimum pause time when dialling at 10PPS.
Minimum pause time can be set from 800 to 950ms in 10ms
increments by binary inputting N over the range of 0 to 15 (N
x 10ms + 800ms).
Minimum pause time can be set from 800 to 950ms in 10ms
increments by binary inputting N over the range of 0 to 15 (N
x 10ms + 800ms).
0
"0000": 800ms
(Other country)
"0001": 810ms (France)
(Other country)
"0001": 810ms (France)
Adjustment
value
value
0
0
0
0
0
5-8
Calling
Minimum pause time
(20PPS) setting
(20PPS) setting
Setting of minimum pause time when dialling at 20PPS.
Minimum pause time can be set from 450 to 600ms in 10ms
increments by binary inputting N over the range of 0 to 15 (N
x 10ms + 450ms).
Functions only in China and Thailand.
Minimum pause time can be set from 450 to 600ms in 10ms
increments by binary inputting N over the range of 0 to 15 (N
x 10ms + 450ms).
Functions only in China and Thailand.
0
450ms
Adjustment
value
value
0
0
0
0
0
4
1-4
Calling
Make time (20PPS)
setting
setting
Setting of make time when dialing at 20PPS.
Make time can be set from 9 to 24ms by binary inputting N
over the range of 0 to 15 (N + 9ms).
Functions only in China and Thailand.
Make time can be set from 9 to 24ms by binary inputting N
over the range of 0 to 15 (N + 9ms).
Functions only in China and Thailand.
1
"1000": (Other country)
"1010": 19ms (China/
Thailand/Hong Kong)
"1010": 19ms (China/
Thailand/Hong Kong)
Adjustment
value
value
0
0
0
0
0
5-8
Calling
Break time setting
(20PPS)
(20PPS)
Setting of break time when dialing at 20PPS.
Break time can be set from 26 to 41ms by binary inputting N
over the range of 0 to 15 (N + 26ms).
Functions only in China and Thailand.
Break time can be set from 26 to 41ms by binary inputting N
over the range of 0 to 15 (N + 26ms).
Functions only in China and Thailand.
0
"0111": (Other country)
"0101": 31ms (China/
Thailand/Hong Kong)
"0101": 31ms (China/
Thailand/Hong Kong)
Adjustment
value
value
1
1
1
1
1
5
1-4
Calling
Setting of DTMF send
level (high group)
level (high group)
This sets the send level of high area and low area DTMF
signals in units of 1dB.
Setting can be made over the range of 0dB to 15dB in 1dB
increments by binary inputting.
signals in units of 1dB.
Setting can be made over the range of 0dB to 15dB in 1dB
increments by binary inputting.
0
"0101": 5dB (North
America/Singapore)
"0011": 3dB
(Other3/Russia)
"0110": 6dB
(Other country)
"0111": 7dB (Australia/
Malaysia/Philippine/
Hong Kong/Middle East)
"1000": 8dB (Indonesia/
South Africa/Brazil)
"1001": 9dB (India)
America/Singapore)
"0011": 3dB
(Other3/Russia)
"0110": 6dB
(Other country)
"0111": 7dB (Australia/
Malaysia/Philippine/
Hong Kong/Middle East)
"1000": 8dB (Indonesia/
South Africa/Brazil)
"1001": 9dB (India)
Adjustment
value
value
1
0
1
5-8
Not used
0
0
0
0
0
0
0
MXFXX3 SIMULATIONS, FAX SOFTWARE SWITCH 3 – 29
6
1-4
Calling
Setting of DTMF send
level (low group)
High group - Low
group: level difference
level (low group)
High group - Low
group: level difference
This sets the difference between the DTMF signal high area
level and low area level in units of 0.5dB.
Setting can be made over the range of -2.0dB to 5.5dB in
0.5dB increments by binary inputting.
High group - Low group
"0 0 0 0": -2.0dB
level and low area level in units of 0.5dB.
Setting can be made over the range of -2.0dB to 5.5dB in
0.5dB increments by binary inputting.
High group - Low group
"0 0 0 0": -2.0dB
"1 0 0 0": 2.0dB
"0 0 0 1": -1.5dB
"1 0 0 1": 2.5dB
"0 0 1 0": -1.0dB
"1 0 1 0": 3.0dB
"0 0 1 1": -0.5dB
"1 0 1 1": 3.5dB
"0 1 0 0": 0.0dB
"1 1 0 0": 4.0dB
"0 1 0 1": 0.5dB
"1 1 0 1": 4.5dB
"0 1 1 0": 1.0dB
"1 1 1 0": 5.0dB
"0 1 1 1": 1.5dB
"1 1 1 1": 5.5dB
1
"1000": 2.0dB
(Other country)
"0100": 0.0dB
(New Zealand)
"1010": 3.0dB (Australia)
(Other country)
"0100": 0.0dB
(New Zealand)
"1010": 3.0dB (Australia)
Adjustment
value
value
0
0
0
5-8
Not used
0
0
0
0
0
0
0
7
1-8
Calling
Setting of DTMF
minimum pause time
minimum pause time
This sets the minimum pause time between DTMF signals
when sending DTMF signals.
Minimum pause time can be set by binary inputting N over the
range of 0 to 255 (1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms
increments by binary inputting.
When SW15-3,4 are set to other than "MODEM fixed," the set
value less than 54ms is considered as 54ms.
The initial value is reverted to if a value outside of the setting
range is set.
when sending DTMF signals.
Minimum pause time can be set by binary inputting N over the
range of 0 to 255 (1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms
increments by binary inputting.
When SW15-3,4 are set to other than "MODEM fixed," the set
value less than 54ms is considered as 54ms.
The initial value is reverted to if a value outside of the setting
range is set.
0
120ms
Adjustment
value
value
1
1
1
1
0
0
0
1
1
1
0
0
0
8
1-5
Calling
DTMF signal send time
This sets the time that DTMF signals are sent when sending
DTMF signals.
Send time can be set over the rage of 70 to 310ms in 10ms
increments by binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting
range is set.
DTMF signals.
Send time can be set over the rage of 70 to 310ms in 10ms
increments by binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting
range is set.
0
110ms
Adjustment
value
value
1
0
1
1
0
1
1
6, 7
Calling
Dial call waiting time
This sets the waiting time from the end of line connection to
the start of dial call at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
the start of dial call at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
0
"00": 3.5 seconds
(Other country)
"01": 4 seconds (U.K./
Finland/Norway/Denmark/
Netherlands/Italy/New
Zealand/Slovakia/South
Africa/Spain/Portuguese/
Luxemburg/Belgium/
Czech/Hungary/Greece/
Poland)
(Other country)
"01": 4 seconds (U.K./
Finland/Norway/Denmark/
Netherlands/Italy/New
Zealand/Slovakia/South
Africa/Spain/Portuguese/
Luxemburg/Belgium/
Czech/Hungary/Greece/
Poland)
Adjustment
value
value
0
8
Calling
Line current detection
at times of dial calling
at times of dial calling
Setting to determine whether or not to call dial following
detection of line current during line connection at times of
automatic dial calling.
"1": No
"0": Yes
In cases where the setting is "Yes" but no line current can be
detected, dial is not called but the busy re-call procedure is
followed.
detection of line current during line connection at times of
automatic dial calling.
"1": No
"0": Yes
In cases where the setting is "Yes" but no line current can be
detected, dial is not called but the busy re-call procedure is
followed.
1
"1": No (North America/
Taiwan/Middle East/
Other3/Russia)
"0": Yes (Other country)
Taiwan/Middle East/
Other3/Russia)
"0": Yes (Other country)
Setting
9
1
Calling
Manual calibration
setting when sending
setting when sending
Setting to execute the manual calibration or not when
sending.
In case of an abnormal current waveform, the auto calibration
fails and the DTFM signal is deformed. This setting provides
the countermeasure against that problem.
"0": Execute
"1": Not execute
sending.
In case of an abnormal current waveform, the auto calibration
fails and the DTFM signal is deformed. This setting provides
the countermeasure against that problem.
"0": Execute
"1": Not execute
0
Execute
Setting
2
Call
arrival
arrival
Manual calibration
setting when a signal
arrives
setting when a signal
arrives
Setting to execute the manual calibration or not when a signal
arrives.
In case of an abnormal current waveform, the auto calibration
fails and the transmission is affected. This setting provides
the countermeasure against that problem.
"0": Execute
"1": Not execute
arrives.
In case of an abnormal current waveform, the auto calibration
fails and the transmission is affected. This setting provides
the countermeasure against that problem.
"0": Execute
"1": Not execute
0
Execute
Setting
3, 4
Not used
1
1
1
5
Calling
SDT signal detection
Setting to determine whether or not to detect the SDT signal,
which is the second dial tone when transmitting to the F-net.
When the SDT signal is not detected, ordinary dialling is
conducted even after 16X dialling.
"0": Do not detect
"1": Detect
which is the second dial tone when transmitting to the F-net.
When the SDT signal is not detected, ordinary dialling is
conducted even after 16X dialling.
"0": Do not detect
"1": Detect
0
Do not detect
Setting
6
Calling
No. 2 dial tone
detection
detection
Setting of ON/OFF of No.2 dial tone detection function.
"0": OFF (No. 2 dial tone detection is not performed.)
"1": ON (No. 2 dial tone detection is performed.)
"0": OFF (No. 2 dial tone detection is not performed.)
"1": ON (No. 2 dial tone detection is performed.)
0
Detection is not performed
Setting
SW
No.
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings
MXFXX3 SIMULATIONS, FAX SOFTWARE SWITCH 3 – 30
9
7
Calling
Dial tone detection
When the setting is "Yes," the dial is sent following
confirmation of detection of the dial tone when the line is
captured; and when the setting is "No," dial is sent without a
dial tone because no confirmation of dial tone detection is
carried out after line capture.
"0": No
"1": Yes
confirmation of detection of the dial tone when the line is
captured; and when the setting is "No," dial is sent without a
dial tone because no confirmation of dial tone detection is
carried out after line capture.
"0": No
"1": Yes
1
"1": Yes (Other country)
"0": No (Australia/New
Zealand/China/Indonesia/
Thailand/Malaysia/India/
Philippine/Hong Kong/
Taiwan/Middle East/
Other3/Russia)
"0": No (Australia/New
Zealand/China/Indonesia/
Thailand/Malaysia/India/
Philippine/Hong Kong/
Taiwan/Middle East/
Other3/Russia)
Setting
8
Calling
Dial tone ON detection
time (during
continuous detection)
time (during
continuous detection)
This sets the waiting time from the end of line connection to
the start of dial call at times of automatic dial calling.
"0": 1.5 seconds
"1": 1 seconds
the start of dial call at times of automatic dial calling.
"0": 1.5 seconds
"1": 1 seconds
0
1.5 seconds
Adjustment
value
value
10
1-4
Calling
Lower limit of dial tone
ON/OFF detection time
(during intermittent
detection)
ON/OFF detection time
(during intermittent
detection)
This sets the lower limit time for detection of dial tone ON/
OFF time.
Setting can be made over the range of 40ms to 490ms in
30ms increments by binary inputting.
(N x 30ms) + 40ms
This is only valid during intermittent DT detection.
OFF time.
Setting can be made over the range of 40ms to 490ms in
30ms increments by binary inputting.
(N x 30ms) + 40ms
This is only valid during intermittent DT detection.
0
"0010": 100ms (North
America/Australia/New
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/Brazil)
"0001": 70ms
(Other country)
America/Australia/New
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/Brazil)
"0001": 70ms
(Other country)
Adjustment
value
value
0
1
0
5-8
Calling
Upper limit of dial tone
ON/OFF detection time
(during intermittent
detection)
ON/OFF detection time
(during intermittent
detection)
This sets the upper limit time for detection of dial tone ON/
OFF time.
Setting can be made over the range of 400ms to 1900ms in
100ms increments by binary inputting.
(N x 100ms) + 400ms
This is only valid during intermittent DT detection.
OFF time.
Setting can be made over the range of 400ms to 1900ms in
100ms increments by binary inputting.
(N x 100ms) + 400ms
This is only valid during intermittent DT detection.
0
"0011": 700ms (North
America/Australia/New
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/Brazil)
"1000": 1200ms
(Other country)
America/Australia/New
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle
East/Other3/Brazil)
"1000": 1200ms
(Other country)
Adjustment
value
value
0
1
1
11
1-4
Calling
External line
connection number
setting 1 <First digit>
connection number
setting 1 <First digit>
When No. 2 dial tone is detected, this area is compared with
the external in connection number. If they match, the units
waits for No. 2 dial tone.
Up to two external line connection numbers (max. 4 digits)
can be registered as options.
The first digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
the external in connection number. If they match, the units
waits for No. 2 dial tone.
Up to two external line connection numbers (max. 4 digits)
can be registered as options.
The first digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
5-8
Calling
External line
connection number
setting 1 <Second
digit>
connection number
setting 1 <Second
digit>
The second digit of the external line connection number 1 is
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
12
1-4
Calling
External line
connection number
setting 1 <Third digit>
connection number
setting 1 <Third digit>
The third digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
0
5-8
Calling
External line
connection number
setting 1 <Fourth digit>
connection number
setting 1 <Fourth digit>
The fourth digit of the external line connection number 1 is
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
0
13
1-4
Calling
External line
connection number
setting 2 <First digit>
connection number
setting 2 <First digit>
The first digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
0
5-8
Calling
External line
connection number
setting 2 <Second
digit>
connection number
setting 2 <Second
digit>
The second digit of the external line connection number 2 is
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
set.
The numbers and codes which can be registered are as
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) /
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
0
SW
No.
No.
Bit
No.
Item
SW selection and function
Initial value
System
settings