Copying Equipment / NOV 10-REVISED MX-FXX3 SERVICE MANUAL
File
mx-fxx3.pdf
Date

Sharp MX-FXX3 Service Manual ▷ View online

MXFXX3  SIMULATIONS, FAX SOFTWARE SWITCH  3 – 31
14
1-4
Calling
External line 
connection number 
setting 2 <Third digit>
The third digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as 
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / 
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
5-8
Calling
External line 
connection number 
setting 2 <Fourth digit>
The fourth digit of the external line connection number 2 is 
set.
The numbers and codes which can be registered are as 
follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / 
Not used for this digit and after (d) / Any is OK (f)
When set to [e], it is considered as setting to [0].
0
0
Setting
0
0
0
15
1, 2
Calling
DT/BT detection level
This sets the minimum detection level for determining that 
dial tone and busy tone have been detected. Signal levels not 
larger than this setting are ignored.
"00": -43dB
"01": -35dB
"10": -33dB
"11": -30dB
DT, BT common
0
-43dB
Adjustment 
value
0
3, 4
Calling
DT/BT detection 
frequency range 
setting
This sets the detection frequency range when detecting dial 
tone and busy tone.
Change the setting if dial tone and busy tone are erroneously 
detected.
"00": MODEM fixed (about 308Hz - 517Hz)
"01": 420Hz - 680Hz
"10": 360Hz - 440Hz
"11": 245Hz - 650Hz
For CTR21: 245Hz - 650Hz
1
"11": 245Hz - 650Hz 
(Other country)
"00": MODEM fixed 
(Thailand/India)
"01": 420Hz - 680Hz 
(China)
"10": 360Hz - 440Hz 
(Indonesia/Malaysia/
Middle East/Other3/
Russia)
Adjustment 
value
1
5
Calling
Busy tone detection
Setting to determine whether or not to detect the busy tone 
signal during automatic dial calling and when the external 
telephone simulated call sound is ringing.
"0": Detect
"1": Do not detect
0
Detect
Setting
6
Calling
Busy tone OFF non-
detection time
This sets the non-detection time on the busy tone OFF 
section.
Change the setting in cases where noise, etc. on the busy 
tone ON section adversely affects the ON section.
"0": 100ms
"1": 300ms
* Make shorter than the "busy tone OFF detection time."
0
100ms
Adjustment 
value
7, 8
Calling
Lower limit of busy 
tone ON detection time
This sets the lower limit time of the ON section when 
detecting frequency of the busy tone signal.
If busy tone signals are not detected in excess of this time, do 
not count as 1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
0
"00": 250ms (North 
America/Australia/New 
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle 
East/Other3/South Africa)
"01": 140ms 
(Other country)
Adjustment 
value
0
16
1, 2
Calling
Upper limit of busy 
tone ON detection time
This sets the upper limit time of the ON section when 
detecting frequency of the busy tone signal.
If busy tone signal is detected in excess of this time, do not 
count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
0
"00": 750ms 
(Other country)
"10": 1000ms 
(Australia/India)
"11": 2850ms 
(Singapore/South Africa)
Adjustment 
value
0
3, 4
Calling
Lower limit of busy 
tone OFF detection 
time
This sets the lower limit time of the OFF section when 
detecting frequency of the busy tone signal.
If busy tone OFF signals are not detected in excess of this 
time, do not count as 1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
0
"00": 250ms (North 
America/Australia/New 
Zealand/China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle 
East/Other3/South Africa)
"01": 140ms 
(Other country)
Adjustment 
value
0
5, 6
Calling
Upper limit of busy 
tone OFF detection 
time
This sets the upper limit time of the OFF section when 
detecting frequency of the busy tone signal.
If busy tone signal is detected in excess of this time, do not 
count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
0
"00": 750ms 
(Other country)
"10": 1000ms (Singapore/
India/South Africa)
Adjustment 
value
0
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
MXFXX3  SIMULATIONS, FAX SOFTWARE SWITCH  3 – 32
16
7, 8
Not used
0
0
17
1-4
Call 
arrival
Call signal OFF non-
detection time
This sets the time for ignoring OFF signals and regarding ON 
time to be continuous following ON detection of the call signal 
(CI).
This is intended to treat the PBX call signal "ring-ring" as a 
single call signal.
Setting can be made over the range of 0ms to 1500ms in 
100ms increments by binary inputting.
0
"0110": 600ms (North 
America/Australia/Taiwan/
Middle East/Other3/
Russia)
"0100": 400ms 
(Other country)
"1010": 1000ms 
(New Zealand)
Adjustment 
value
1
1
0
5-8
Call 
arrival
Lower limit of call 
signal ON time
This sets the minimum ON time for detecting call signal (CI) 
pulses (number of pulses). 1 pulse is counted if the CI signal 
remains ON for the set ON time or longer.
Setting can be made over the range of 150ms to 300ms in 
10ms increments by binary inputting.
0
"0000": 150ms 
(Other country)
"0010": 170ms (Australia)
Adjustment 
value
0
0
0
18
1-4
Call 
arrival
Upper limit of call 
signal ON time
This sets the maximum ON time for detecting call signal (CI) 
pulses (number of pulses). Disregard and do not count as 1 
pulse if the CI signal remains ON for the set ON time or 
longer.
Setting can be made over the range of 3000ms to 4500ms in 
100ms increments by binary inputting.
0
3000ms
Adjustment 
value
0
0
0
5-8
Call 
arrival
Lower limit of call 
signal OFF time
This sets the minimum OFF time for detecting call signal (CI) 
pulses (number of pulses). 1 pulse is counted if the CI signal 
remains OFF for the set OFF time or longer.
Setting can be made over the range of 100ms to 1500ms in 
100ms increments by binary inputting.
Setting range
When 0 is set, initial value 700ms operation takes place.
0
700ms
Adjustment 
value
1
1
1
19
1, 2
Call 
arrival
Upper limit of call 
signal OFF time
This sets the maximum waiting time from detection of the call 
signal (CI) pulse (number of pulses) to detection of the next 
CI signal pulse.
Accordingly, if the next CI signal pulse is not detected within 
this time, the number of calls up to now is cleared.
"00": 6.5 seconds
"01": 10 seconds
"10": 15 seconds
"11": 20 seconds
0
"00": 6.5 seconds 
(Other country)
"01": 10 seconds 
(Sweden/Indonesia)
Adjustment 
value
0
3
Call 
arrival
CI clear judgment
Setting of the judgment of CI signal 1 cycle.
"1": Cleared only when the max. cycle is exceeded. (The min. 
cycle is 0.)
"0": Cleared when outside the range of 1 cycle. (The min. and 
the max. cycles are set with other soft switches.)
0
Cleared when outside the 
range of 1 cycle.
4, 5
Call 
arrival
Filter time when the CI 
signal is detected. 
The detection sampling time of the CI signal is set in the CI 
signal detection setting.
"00": 10ms
"01": 5ms
"10": 15ms
"11": 20ms
0
10ms
0
6-8
Not used
0
0
0
20
1-8
Not used
0
0
0
0
0
1
0
1
21
1-8
Not used
1
0
1
0
0
0
0
0
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
MXFXX3  SIMULATIONS, FAX SOFTWARE SWITCH  3 – 33
Communications
22
1-8
Not used
0
0
0
0
0
0
0
0
23
1-8
Not used
0
0
0
0
0
0
0
0
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
24
1-8
Communication
Signal sending level
Set the level adjustment for sending signals from 
the modem. Setting can be made over the range 
of 0 to 26 in 1dBm increments by binary inputting.
Since the maximum level differs according to 
country, if a value above the maximum level is 
set, the maximum value for the present country 
code will be adopted. (For North America and 
China, there is no limitation on the max. send 
level.)
When set to a value greater than the upper limit, it 
is considered as setting to the upper limit. When 
set to a value smaller than the lower limit, it is 
considered as setting to the lower limit.
If, however, it is set to 27 to 255, it is considered 
as setting to 26.
0
"00001011": -11dBm 
(North America/Australia/
New Zealand/India/
Taiwan/Russia)
"00001000": -8dBm 
(Other3)
"00001001": -9dBm 
(Other country)
"00001010": -10dBm 
(China/Singapore/
Thailand/Malaysia/
Philippine/Hong Kong/
Middle East/Brazil)
Adjustment 
value
0
0
0
1
0
1
1
25
1-3
Transmission
Setting of call time (T0 
timer setting) in 
automatic transmission
Setting to determine how many seconds to call 
when the other party doesn’t respond at times of 
automatic transmission.
Setting can be made over the range of 30 to 60 
(China: 30 to 45, Russia: 30 to 35) seconds in 15 
(Russia: 5) second increments by binary inputting 
N ((15 (Russia: 5) seconds x N) + 30 seconds).
The initial value is reverted to if a value outside of 
the setting range is set.
0
45 seconds 
(Other country)
35 seconds (Russia)
Timer
0
1
4-7
Communication
T1 timer setting
Setting to determine how many seconds the line 
is connected when the other party’s machine 
doesn’t respond to FAX communication.
Setting can be made over the range of 30 to 105 
seconds in 5-second increments by binary 
inputting ((5 seconds x N) + 30 seconds).
T1 timer is the timer used from the point where 
the other party’s machine recognizes (CED or 
DCS) as FAX following line connection. 35±5 
seconds according to the ITU-T standard.
0
40 seconds
Timer
0
1
0
8
Not used
0
26
1, 2
Communication
T2 timer setting
The time until a command is received is set.
"00": 6 seconds
"01": 7 seconds
"10": 8 seconds
"11": 9 seconds
This is the timer for receiving a command such as 
the DIS signal. 6
1 seconds in the ITU-T 
standards. 
0
6 seconds
0
3, 4
Communication
T4 timer setting 
Timer during automatic 
operation (+1.5 
seconds at times of 
manual operation)
This sets the timer for up until reception of the 
response.
+1.5 seconds at times of manual operation
"00": 3 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This is the timer for up until reception of the 
response to the DCS signal, etc. 3 seconds ±15% 
under the ITU-T standard.
0
3 seconds
Timer
0
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
MXFXX3  SIMULATIONS, FAX SOFTWARE SWITCH  3 – 34
26
5
Reception
EOL detection timer
Setting to determine how many seconds to set the 
detection timer for EOL (EndOfLine) during 
Phase-C reception in G3.
"0": Setting to 13 seconds
"1": Setting to 25 seconds
When error occurs in EOL detection, treat as non-
detection of EOL.
0
13 seconds
Timer
6
Communication
Sharp machine mode
Setting is made whether Sharp's unique 
procedures (relay, confidential) are allowed or not 
by not sending NSF/NSS/NSC and not confirming 
that the machine is a Sharp machine or not.
"0": Check
"1": Not check
0
Check
7, 8
Communication
Modem lightning 
protection measures
Function that corresponds to IEC lightning surge 
requirements as prescribed in the European CE 
standard.
In cases where the machine cannot shift from 
CFR or MCF to high-speed signals (image 
signals) due to lightning interference, this extends 
the MPS waiting time.
"00": 0 second
"01": 20 seconds
"10": 30 seconds
"11": 40 seconds
0
"00": 0 second (North 
America/New Zealand/
China/Singapore/
Indonesia/Thailand/
Malaysia/India/Philippine/
Hong Kong/Taiwan/Middle 
East/Other3/Russia/
Brazil)
"01": 20 seconds 
(Other country)
Setting
0
27
1, 2
Reception
CED signal sending 
time
This sets the time over which the CED signal is 
sent.
"00": 3 seconds
"01": 4 seconds
"10": 5 seconds
"11": No
0
3 seconds
Communication/
Adjustment 
value
0
3
Reception
CED/ANSam detection 
time
This sets the time up until determination of the 
signal when detecting CED/ANSam signals.
"0": 500ms
"1": 1000ms
1
1000ms
Adjustment 
value
4
Reception
V.34 mode function (on 
call arrival)
Setting to determine whether or not to make the 
V.34 mode valid as machine capacity when 
receiving (on call arrival).
"0": V.34 valid
"1": V.34 invalid
0
V.34 valid
Setting
5
Transmission
V.34 mode function 
(including polling when 
calling)
Setting to determine whether or not to make the 
V.34 mode valid as machine capacity when 
transmitting (calling and polling).
"0": V.34 valid
"1": V.34 invalid
0
V.34 valid
Setting
6
Transmission
V.34 mode function at 
times of manual 
communication
Setting to determine whether or not to make the 
V.34 mode valid at times of manual 
communication (transmitting and receiving).
"0": V.34 valid
"1": V.34 invalid
However, in cases where the V.34 mode function 
(including polling when calling) is set at 1: V.34 
invalid, the V.34 mode will be rendered invalid 
even if this SW is set to 0: valid.
0
V.34 valid
Communication/
Setting
7
Transmission
3429 symbol rate 
transmission enable 
during V.34 
transmission.
Setting to determine whether or not to enable 
3429Hz as the symbol rate for V.34.
When this is at "disable," 3429Hz is not selected.
However, only valid during transmission.
"0": disable
"1": enable
1
enable
Setting
8
Transmission
Symbol rate 3200 high 
carrier transmission 
enable during V.34 
transmission
When 3200Hz is selected as the V.34 symbol 
rate, there are Low/High carriers, but this setting 
determines whether or not both can be used.
When this is at "disable," 3200 High is not 
selected.
However, only valid during transmission.
When both Low/High are at "disable," 
SymbolRate=3200Hz is not selected.
"0": disable
"1": enable
1
enable
Setting
28
1
Transmission
Symbol rate 3200 low 
carrier transmission 
enable during V.34 
transmission
When 3200Hz is selected as the V.34 symbol 
rate, there are Low/High carriers, but this setting 
determines whether or not both can be used.
When this is at "disable," 3200 Low is not 
selected.
However, only valid during transmission.
"0": disable
"1": enable
1
enable
Setting
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings