DOWNLOAD Sharp MX-FXX2 (serv.man2) Service Manual ↓ Size: 4.88 MB | Pages: 80 in PDF or view online for FREE

Model
MX-FXX2 (serv.man2)
Pages
80
Size
4.88 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / MX-FXX2 Service Manual (Complete)
File
mx-fxx2-sm2.pdf
Date

Sharp MX-FXX2 (serv.man2) Service Manual ▷ View online

MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 18
 
66-36
Purpose
Operation test/Check
Function (Purpose) Used to check send and receive data from
the MODEM controller to the MFP control-
ler or the data line or the command line
individually.
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-36, the following
screen is displayed. (Default: left upper selected)
2)
Operation check
Select an item to be checked on the screen.
* When an item to be checked is selected, it is highlighted.
3.1. When "Operation check once" is selected:
 When (once) is selected:
When [EXECUTE] button is pressed under this state, [EXECUTE]
button is highlighted and the operation check is started.
After completion of the operation check, [EXECUTE] button returns
to the normal display and the check result is displayed.
When the check is normally completed, "OK" is displayed. In case
of an error, [NG" is displayed.
3.2. When "Operation check repeat" is selected:
 When [repeat] is selected:
When [EXECUTE] button is pressed under this state, [EXECUTE]
button is highlighted and the operation check is started.
* In the case of [Repeat] check, the title display is changed as fol-
lows for every execution of check.
"MFP-MDMC I/F CHECK.- *"
"MFP-MDMC I/F CHECK.- **"
"MFP-MDMC I/F CHECK.- ***"
"MFP-MDMC I/F CHECK.- ****"
"MFP-MDMC I/F CHECK.- *****"
Check is repeated until [EXECUTE] button is pressed or "NG"
occurs.
To stop the operation check, press [EXECUTE] button, and
[EXEUTE] button returns to the normal display and the operation
check is terminated.
* When an abnormality occurs during check, "NG" is displayed
and the operation is terminated.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<MFP controller I/F check item table>
 
66-39
Purpose
Setting
Function (Purpose) Used to check and change the destination
setting saved in EEPROM of the FAX BOX.
Section
FAX
Item
Specifications
Operation/Procedure
1)
When the machine enters the simulation, the currently set des-
tination button is highlighted. (In the default state, JAPAN is set
as the destination.)
2)
Select a destination button to set the destination. (In this
example, USA/CANADA is selected.) The selected button is
highlighted and the previously selected button returns to the
normal display.
* When the destination button is changed, the new destination
setting is saved to EEPROM of the FAX BOX.
* When, however, there is no destination setting in EERPOM
of the FAX BOX, "NO DESTINATION" is displayed on the
title line and all the destination buttons are normally dis-
played.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<Destination setting table>
 
66-42
Purpose
Setting
Function (Purpose) Used to rewrite the program to power con-
trol installed in the FAX BOX.
Section
Item
Operation/Procedure
1)
Press [EXECUTE] button.[EXECUTE] button is highlighted
and YES] and [NO] buttons become active.
2)
Press [YES] button.
The power control program is rewritten.
* During rewriting the power control program, [EXECUTE] and
[YES] buttons are highlighted.
* When [NO] button or [EXECUTE] button is pressed, [EXE-
CUTE] button returns to the normal display, and [YES] and
[NO] buttons gray out.
3)
When rewriting of the power control program is normally com-
pleted, "OK" is displayed and [EXECUTE] button returns to the
normal display, and [YES] and [NO] buttons gray out.
* When rewriting of the power control program is failed, the
error message of "NG"is displayed and [EXECUTE] button
returns to the normal display, and [YES] and [NO] buttons
gray out.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
MFP 
← MDMC (DATA once)
Data line Once
MFP 
→ MDMC (DATA once)
Data line Once
MFP 
← MDMC (DATA repeat)
Data line Repeat
MFP 
→ MDMC (DATA repeat)
Data line Repeat
MFP 
← MDMC (CMD once)
Command line Once
MFP 
→ MDMC (CMD once)
Command line Once
MFP 
← MDMC (CMD repeat)
Command line Repeat
MFP 
→ MDMC (CMD repeat)
Command line Repeat
SIMULATION NO.66-36
CLOSE
TEST
MFP-MDMC I/F CHECK.
0
MFP<-MDMC(DATA once)
MFP->MDMC(DATA once)
MFP<-MDMC(DATA repeat)
MFP->MDMC(DATA repeat)
MFP<-MDMC(CMD once)
MFP->MDMC(CMD once)
MFP<-MDMC(CMD repeat)
MFP->MDMC(DATA repeat)
EXECUTE
JAPAN
U.S.A/CANADA
EUROPE
AUSTRALIA
CHINA
ASIA&OTHERS
SIMULATION NO.66-39
CLOSE
TEST
FAX DESTINATION SETUP
0
JAPAN
U.S.A/CANADA
AUSTRALIA
EUROPE
CHINA
ASIA&OTHERS
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 19
 
66-43
Purpose
Setting
Function (Purpose) Used to write the adjustment value into the
power control installed in the FAX BOX.
Section
FAX
Item
Setting
Operation/Procedure
1)
When the machine enters Simulation 66-43, the following
screen is displayed. (Default: left upper selected)
* Use [
↑] [↓] buttons to select the select item of the power
control adjustment value. Selection is made in Item A to H.
When the selected item is the top (last) item,  [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and the new value is displayed on the setting
area.)
When [
↑] [↓] buttons gray out, they are disabled.
* Enter the power control adjustment value with 10-key and
press [OK] button ([
↑] [↓] buttons). The set power control
adjustment value is saved to the primary memory area.
* The set data are saved in the primary memory area. There-
fore, the setting is reflected only when [EXECUTE] button is
pressed to execute.
* For the range of the power control adjustment value and
each value, refer to the table.
2)
When [EXECUTE] key is pressed, it is highlighted and writing
to the power control is executed. When writing is normally
completed, "OK" is displayed. When it is failed, "NG" is dis-
played.
3)
After completion of writing, [EXECUTE] key returns to the nor-
mal display.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<Set range and default value of each set value>
 
66-60
Purpose
Setting
Function (Purpose) Used to provide the user the auto select
function of a low-cost line by dialing with
addition of the prefix to the dial number
when calling
Section
FAX
Item
Setting
Operation/Procedure
1)
When the machine enters Simulation 66-60, the following
screen is displayed.
* Use  [
↑] [↓] buttons to select the ACR data select page.
When the selected item is the top (last) item, [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and displayed on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
* In the column of [PRESENT:], the current ACR data code is
displayed. (The data content varies depending on the code.
When the data code is not registered, "Blank" is displayed.)
2)
When a button of ACR data item to be changed is selected,
the selected button is highlighted and the previously set button
returns to the normal display. At that time, the content of
[PRESENT:] is also changed according to the newly selected
ACR data.
* Only one ACR data item to be changed can be selected.
3)
Enter ACR data with 10-key ([0] - [9]). The ACR data is entered
to the column of NEW.
4)
Press SET button to change the setting to the entered value of
ACR data. The entered value is saved and displayed (regis-
tered) in the column of [PRESENT:] and the column of [NEW:]
becomes blank.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
Item
Set range
Default value
A
CI_LEVEL_JUDGE
2 to 15
6
B
CI_CYCLE_MIN
1 to 254
10
C
CI_CYCLE_MAX
2 to 255
142
D
CI_COUNT
2 to 15
3
E
RES_3.3V_LEVEL_JUDGE
2 to 15
15
F
EXHS_LEVEL_JUDGE
2 to 225
240
G
RHS_LEVEL_JUDGE
2 to 15
2
H
SON_TIMEOUT
1 to 127
20
SIMULATION NO.66-42
CLOSE
TEST
POWER CONTROL PROGRAM RELOAD
0
EXECUTE
ARE YOU SURE?
YES
NO
ǂǂǂ
SIMULATION NO.66-43
CLOSE
TEST
POWER CONTROL ADJUSTMENT VALUE WRITING.
0
6
A
2
15
CL_LEVEL_JUDGE
A :
6
CL_CYCLE_MIN
B : 10
CL_CYCLEMAX
C : 142
CL_COUNT
D :
3
EXHS_LEVEL_JUDGE
F : 240
RES_3.3V_LEVEL_JUDGE
E : 15
RHS_LEVEL_JUDGE
G :
2
SON_TIMEOUT
H: 20
OK
EXECUTE
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 20
 
66-61
Purpose
Setting
Function (Purpose) Used to display the FAX-related soft SW
(100 - 170) on the LCD to allow changing
the soft SW while checking with the LCD.
Section
FAX
Item
Setting
Operation/Procedure
1)
Enter the [SW NO] with 10-key.
* When [C] key is pressed, the entered value of [SW NO] is
cleared.
2)
Press [DATA] button.
The soft SW data entered in procedure 1) is displayed.
* When [SW NO] button is pressed, the display returns to the
initial screen.
3)
Enter the number corresponding to the bit to be changed with
10-key.
[1] 
→ [0]
[0] 
→ [1]
* When [SW NO] button is pressed, the display returns to the
initial screen.
4)
When [EXECUTE] button is pressed, it is highlighted and the
setting is saved.
After saving the setting, [EXECUTE] button returns to the nor-
mal display.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
Item
Key display
Data kind
Default
Number of digits
Title line display when entering number
1
LocalCarrierNum
Local carrier prefix
Null
Max. 6
Local Carrier Number
LongCarrierNum.
Local carrier prefix
Null
Max. 6
Long-distance Carrier Number
OverCarrierNum.
Overseas carrier prefix
Null
Max. 6
Overseas Carrier Number
Bypass Num.
Bypass number
9999
Max. 4
Bypass Number
User Area Code
User area code
Null
Max. 6
User Area Code
Machine Code
Machine code
0619
Max. 4
Machine Code
Version
Version number
0100
Max. 4
Version
Thru Num.1
Through number 1
0120
Max. 4
Though Number1
Thru Num.2
Through number 2
0140
Max. 4
Though Number2
Thru Num.3
Through number 3
0150
Max. 4
Though Number3
Thru Num.4
Through number 4
0160
Max. 4
Though Number4
Thru Num.5
Through number 5
0170
Max. 4
Though Number5
Thru Num.6
Through number 6
0180
Max. 4
Though Number6
Thru Num.7
Through number 7
0190
Max. 4
Though Number7
Thru Num.8
Through number 8
020
Max. 4
Though Number8
Thru Num.9
Through number 9
030
Max. 4
Though Number9
Thru Num.10
Through number 10
0330
Max. 4
Though Number10
Thru Num.11
Through number 11
0360
Max. 4
Though Number11
Thru Num.12
Through number 12
040
Max. 4
Though Number12
Thru Num.13
Through number 13
0450
Max. 4
Though Number13
Thru Num.14
Through number 14
050
Max. 4
Though Number14
Thru Num.15
Through number 15
0570
Max. 4
Though Number15
Thru Num.16
Through number 16
060
Max. 4
Though Number16
Thru Num.17
Through number 17
070
Max. 4
Though Number17
Thru Num.18
Through number 18
0750
Max. 4
Though Number18
Thru Num.19
Through number 19
080
Max. 4
Though Number19
Thru Num.20
Through number 20
0840
Max. 4
Though Number20
Thru Num.21
Through number 21
090
Max. 4
Though Number21
Thru Num.22
Through number 22
0990
Max. 4
Though Number22
Res. Thru Num.1
Reserve Through number 1
Null
Max. 4
Reseve Though Number
Res. Thru Num.2
Reserve Through number 2
Null
Max. 4
Reseve Though Number2
Res. Thru Num.3
Reserve Through number 3
Null
Max. 4
Reseve Though Number3
2
Res. Thru Num.4
Reserve Through number 4
Null
Max. 4
Reseve Though Number4
Res. Thru Num.5
Reserve Through number 5
Null
Max. 4
Reseve Though Number5
Res. Thru Num.6
Reserve Through number 6
Null
Max. 4
Reseve Though Number6
Res. Thru Num.7
Reserve Through number 7
Null
Max. 4
Reseve Though Number7
Res. Thru Num.8
Reserve Through number 8
Null
Max. 4
Reseve Though Number8
SIMULATION NO.66-60
CLOSE
TEST
ACR SETTING.(Local Carrier Number)
0
EXECUTE
1/2
PRESENT:
NEW:
9999
SET
LocalCarrierNum
LongCarrierNum
Bypass Num
OverCarrierNum
User Area Code
Machine Code
Thru Num.1
Version
Thru Num.2
Thru Num.3
Thru Num.5
Thru Num.4
Thru Num.6
Thru Num.7
Thru Num.9
Thru Num.8
Thru Num.10
Thru Num.11
Thru Num.13
Thru Num.12
Thru Num.14
Thru Num.15
Thru Num.17
Thru Num.16
Thru Num.18
Thru Num.19
Thru Num.21
Thru Num.20
Thru Num.22
Res. Thru Num.1
Res. Thru Num.3
Res. Thru Num.2
SIMULATION NO.66-61
CLOSE
TEST
FAX SOFT SW.SETTING
0
EXECUTE
SW No.
DATA
:
:
(SW No.100-170)
1 2 3 4 5 6 7 8
MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 21
2. FAX software switch
A. FAX Soft SW List
Lines
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
1
1-8
Country code
Control is performed according to the set country code.
The destination setting that is set in SIM66-2 as the image 
send function is reflected.
The country code setting cannot be directly made from this 
SW.
1
North America
* For codes of the other 
countries, refer to the 
page of SIM 66-2 
setting.
0
1
1
0
1
0
1
SW 
No.
Bit 
No.
Item
SW selection and function
Initial value
System 
settings
2
1-4
Calling
Make time (10PPS) 
setting
Setting of make time when dialling at 10PPS.
Make time can be set from 29 to 44ms in 1ms increments by 
binary inputting N over the range of 0 to 15 (N + 29ms).
1
"1011": 40ms 
(Other country)
"0100": 33ms (Malaysia/
Taiwan/South Africa/
Brazil)
"0110": 35ms 
(New Zealand/India)
"1000": 37ms (Australia)
"1001": 38ms 
(China/Singapore/
Thailand)
Adjustment 
value
0
1
1
5-8
Calling
Break time setting 
(10PPS) 
Setting of break time when dialling at 10PPS. 
Break time can be set from 56 to 71ms by in 1ms increments 
binary inputting  N over the range of 0 to 15 (N + 56ms).
0
"0100": 60ms 
(Other country)
"0110": 62ms 
(China/Singapore/
Thailand/Hong Kong)
"0111": 63ms (Australia)
"1001": 65ms 
(New Zealand/India)
"1011": 67ms
 (Malaysia/Taiwan/
South Africa/Brazil)
Adjustment 
value
1
0
0
3
1-4
Calling
Minimum pause time 
(10PPS) setting
Setting of minimum pause time when dialling at 10PPS.
Minimum pause time can be set from 800 to 950ms in 10ms 
increments by binary inputting N over the range of 0 to 15 (N 
x 10ms + 800ms).
0
"0000": 800ms 
(Other country)
"0001": 810ms (France)
Adjustment 
value
0
0
0
5-8
Calling
Minimum pause time 
(20PPS) setting
Setting of minimum pause time when dialling at 20PPS.
Minimum pause time can be set from 450 to 600ms in 10ms 
increments by binary inputting N over the range of 0 to 15 (N 
x 10ms + 450ms).
Functions only in China and Thailand.
0
450ms
Adjustment 
value
0
0
0
4
1-4
Calling
Make time (20PPS) 
setting
Setting of make time when dialing at 20PPS.
Make time can be set from 9 to 24ms by binary inputting N 
over the range of 0 to 15 (N + 9ms).
Functions only in China and Thailand.
1
"1000": (Other country)
"1010": 19ms (China/
Thailand/Hong Kong)
Adjustment 
value
0
0
0
5-8
Calling
Break time setting 
(20PPS)
Setting of break time when dialing at 20PPS.
Break time can be set from 26 to 41ms by binary inputting N 
over the range of 0 to 15 (N + 26ms).
Functions only in China and Thailand.
0
"0111": (Other country)
"0101": 31ms (China/
Thailand/Hong Kong)
Adjustment 
value
1
1
1
5
1-4
Calling
Setting of DTMF send 
level (high group)
This sets the send level of high area and low area DTMF 
signals in units of 1dB.
Setting can be made over the range of 0dB to 15dB in 1dB 
increments by binary inputting.
0
"0101": 5dB (North 
America/Singapore)
"0011": 3dB 
(Other3/Rusia)
"0110": 6dB 
(Other country)
"0111": 7dB 
(Australia/Malaysia/
Philippine/Hong Kong)
"1000": 8dB (Indonesia/
Middle East/South Africa/
Brazil)
"1001": 9dB (India)
Adjustment 
value
1
0
1
5-8
Not used
0
0
0
0
Page of 80
Display